High accuracy liquid level and interface level detection
The LMT100 is based upon the magnetostrictive principle.
1. The device electronics generates a low energy current
pulse at fixed intervals.
2. The electrical pulses create a magnetic field which
travels down a specialized wire inside the sensor tube.
3. The interaction of the magnetic field around the wire
and the magnetic float causes a torsional stress wave
to be induced in the wire. This torsion propagates
along the wire at a known velocity, from the position of
the magnetic float and toward both ends of the wire.
4. A patented sensing element placed in the transmitter
assembly converts the received mechanical torsion
into an electrical return pulse.
5. The microprocessor-based electronics measures the
elapsed time between the start and return pulses
(Time of Flight) and converts it into a position measure-
ment which is proportional to the level of the float.
LMT100 is preferred for:
• Interface Measurement
• Exceptional performance with emulsion
• Measurement with foam on layers fluid surface
• Hydrocarbons and chemical control
Features:
Options:
Material:
Standard: 316/L Stainless Steel
Options: Alloy 20, Hastelloy® C-276, FEP-TEFLON® jacketed, electropolished 316/316L Stainless
Steel, others on request
Process temperature:
Standard: -195.5 to 121.1ºC (-320 to 250ºF)
Options: up to 427ºC (800ºF) with options
Process pressure:
Standard: -1.0 to 124.1 bar @ 149ºC (-14.7 to 1800 psig @ 300ºF)
Options: 165.47 bar (2400 psig) maximum with the HP probe type
Probe length:
Standard: 304.8mm to 9.14m (1 to 30 ft)
Options: 22.86m (75ft) maximum w/ W7 flexible probe in sensor well
Probe length tolerance:
Standard/Options: ± 3.2mm (0.125in) up to 3.0m (10ft); +/- 6.4mm (0.25in) up to 6.0m (20ft); ± 9.0mm (0.35in) up to 9.0m (29.5ft); +/- 25.4mm (1.0in) up to 22.86m (75ft)
Mounting:
Standard:3/4 in MNPT compression fitting
Options:plugs, threaded fittings, loose flanges a