Subminiature Cartridge Slow Blow Time-Lag 3x10mm 3.6x10mm Tube Glass Fuse
Series:3x10mm glass fuse
Product keywords: No.332/3*10mm 3.6x10mm tube glass fuse
332 series are time-lag and low breaking capacity fuses, suitable for 250V AC voltage, breaking capacity less than 50A protection circuit.
332 series fuses are mainly used in lighting, power supply and power adapters.
Time-current characteristics: Time-lag fuse (T)
Dividing power: 50A@125Vac,35Aor10In@250Vac,50A@250Vac
Standard: IEC 60127-3/IV
Accreditation: cURus,PSE,TUV,CQC,KC
Material: shell - glass tube, metal cap - nickel - plated brass, lead cap - nickel - plated cap, tin - plated copper wire
Operating temperature: -55℃ ~ +125℃
Solderability: 260℃≤5 seconds (wave soldering);350℃≤3 seconds (manual welding)
Welding temperature bearing capacity: 260℃, 10 seconds;280℃, 5 seconds;
Storage condition: +10℃ ~ +60℃;The annual average relative humidity is less than 75%, and the relative humidity reaches 95% for a maximum of not more than 30 days
Time vs Current Characteristics: IEC60127 -3/IV | |||||
Rated current | 150% | 210% | 275% | 400% | 1000% |
250mA~7A | >1h | <2min | 400ms~10s | 150ms~3s | 20ms~150ms |
8A~10A | >1h | <5min | 1s~20s | 150ms~3s | 20ms~ 150ms |
Electrical Characteristics at 25C | |||||||||||||
Rated | Ratede Current | Ratede Voltage | Max Dissipation Drop(mV) | Max.Power Dissipation(mW) | Typical Cold Resistance (mΩ) | Nominal Melting I2t(A2sec) | Breaking Capacity | Approvals | |||||
cURus | PSE | TUV | CQC | KC | |||||||||
125V | 250V | 250V | 250V | 250V | 250V | ||||||||
0250 | 250mA | 250 V AC | 240 | 220 | 600 | 0.221 |
50A/125V AC | ● | ● | ○ | ● | ○ | ● |
0315 | 315mA | 250 V AC | 220 | 250 | 470 | 0.336 | ● | ● | ○ | ● | ○ | ○ | |
0350 | 350mA | 250 V AC | 210 | 250 | 340 | 0.397 | ● | ● | ○ | ○ | ○ | ○ | |
0500 | 500mA | 250 V AC | 190 | 310 | 250 | 1.00 | ● | ● | ○ | ● | ● | ● | |
0630 | 630mA | 250 V AC | 180 | 360 | 150 | 1.35 | ● | ● | ○ | ● | ● | ● | |
0800 | 800mA | 250 V AC | 160 | 430 | 117 | 1.56 | ● | ● | ○ | ● | ● | ● | |
1100 | 1.00A | 250 V AC | 140 | 500 | 80.0 | 6.50 | ● | ● | ● | ● | ● | ○ | |
1125 | 1.25A | 250 V AC | 130 | 600 | 56.0 | 4.62 | ● | ● | ● | ● | ● | ○ | |
1150 | 1.50A | 250 V AC | 120 | 730 | 45.0 | 10.6 | ● | ● | ○ | ○ | ○ | ○ | |
1160 | 1.60A | 250 V AC | 120 | 730 | 50.0 | 10.9 | ● | ● | ● | ● | ● | ○ | |
1200 | 2.00A | 250 V AC | 100 | 870 | 38.0 | 20.3 | ● | ● | ● | ● | ● | ○ | |
1250 | 2.50A | 250 V AC | 100 | 1000 | 28.0 | 32.5 | ● | ● | ● | ● | ● | ○ | |
1315 | 3.15A | 250 V AC | 100 | 1200 | 18.5 | 57.0 | ● | ● | ● | ● | ● | ○ | |
1400 | 4.00A | 250 V AC | 100 | 1400 | 14.5 | 94.1 | ● | ● | ● | ● | ● | ○ | |
1500 | 5.00A | 250 V AC | 100 | 1400 | 12.69 | 121 | ● | ● | ● | ● | ● | ○ | |
1630 | 6.30A | 250 V AC | 100 | 1400 | 8.50 | 225 | ● | ● | ○ | ● | ● | ○ | |
1800 | 8.00A | 250 V AC | 100 | 1400 | 6.40 | 169 | ● | ● | ○ | ○ | ● | ○ | |
2100 | 10.00A | 250 V AC | 100 | 1400 | 3.95 | 196 | ● | ● | ○ | ○ | ○ | ○ |
Note: (1) Permissible continuous operating current is ≤100% at ambient temperature of 23°C (73.4°F)
(2) The cURus certification by 125V and 250V; the others certification by 250V.
(3) The current values used for calculating I2T should be within the standard range of 8ms ~ 10ms.
Series: 3x10mm tube glass fuse
Product keywords: No.312/3*10mm 3.6x10mm time-lag glass fuse
Series 312 are time-lag and low breaking capacity fuses, suitable for 250V AC voltage, breaking capacity less than 50A protection circuit.
Series 312 fuses are mainly used in lighting, power supply and power adapters.
Time-current characteristics: time-lag fuse (T)
Dividing ability: 50A@250Vac / 50A@125VAC
Standard: UL 248-14
Accredited: cULus
Material: shell - glass tube, metal cap - nickel - plated brass, lead cap - nickel - plated cap, tin - plated copper wire
Operating temperature: -55℃ ~ +125℃
Solderability: 260℃≤5 seconds (wave soldering);350℃≤3 seconds (manual welding)
Welding temperature bearing capacity: 260℃, 10 seconds;280℃, 5 seconds;
Storage condition: +10℃ ~ +60℃;The annual average relative humidity is less than 75%, and the relative humidity reaches 95% for a maximum of not more than 30 days
Time vs Current Characteristics: UL248-14 | ||
Rated Current | 100% | 200% |
250mA~10A | >4h | 5s~60s |
Electrical Characteristics at 25℃ | |||||||
Amp Code | Ratede Current | Rated Voltage | Typical cold Resistance(mΩ) | Nominal Melting I²t(A²sec) | Breaking Capacity | Approvals | |
250V AC |
50A @ 250V AC 50A @ 125V AC
| cULus | |||||
0250 | 250mA | 674 | 0.221 | 125V | 250V | ||
0300 | 300mA | 485 | 0.281 | ● | ● | ||
0315 | 315mA | 415 | 0.302 | ● | ● | ||
0350 | 350mA | 340 | 0.384 | ● | ● | ||
0400 | 400mA | 310 | 0.490 | ● | ● | ||
0500 | 500mA | 285 | 0.706 | ● | ● | ||
0750 | 750mA | 114.5 | 1.85 | ● | ● | ||
0800 | 800mA | 140 | 1.00 | ● | ● | ||
1100 | 1.00A | 115 | 5.28 | ● | ● | ||
1125 | 1.25A | 57.8 | 7.29 | ● | ● | ||
1150 | 1.50A | 52.0 | 8.41 | ● | ● | ||
1160 | 1.60A | 45.0 | 8.75 | ● | ● | ||
1200 | 2.00A | 33.0 | 20.3 | ● | ● | ||
1250 | 2.50A | 27.95 | 27.6 | ● | ● | ||
1300 | 3.00A | 25.0 | 64.0 | ● | ● | ||
1315 | 3.15A | 21.0 | 42.3 | ● | ● | ||
1350 | 3.50A | 19.0 | 68.5 | ● | ● | ||
1400 | 4.00A | 14.7 | 96.1 | ● | ● | ||
1500 | 5.00A | 11.9 | 110 | ● | ● | ||
1630 | 6.30A | 8.50 | 228 | ● | ● | ||
1700 | 7.00A | 4.50 | 64.0 | ● | ● | ||
1800 | 8.00A | 6.20 | 77.4 | ● | ● | ||
2100 | 10.00A | 5.10 | 121 | ● | ● |
Note: 1.Permissible continuous operating current is 100% at ambient temperature of 23°C (73.4°F)
2.The current values used for calculating I2T should be within the standard range of 8ms ~ 10ms.
The Miniature Cartridge Fuse is a type of cartridge style fuse, designed to provide reliable overcurrent protection for electronic equipment and electrical systems. It is commonly used in a variety of applications, such as home appliances, industrial machinery, and automotive electronics.
The Miniature Cartridge Fuse is a small, cylindrical device with two axial leads attached to either end. It is manufactured using high-quality materials and advanced technology, making it durable and capable of withstanding high temperatures and harsh environments.
Storage Conditions | +10℃ to +60℃ |
---|---|
Operating Temperature | -55℃ to +125℃ |
Standard | IEC 60127-2/Ⅱ; GB/T9364.7 |
Rated Voltage | 250V AC |
Axial Leads | Tin-plated Copper Wires |
The Miniature Cartridge Fuse is designed to meet international standards and specifications, ensuring its compatibility with a wide range of electronic and electrical systems. It is rated for a maximum voltage of 250V AC, making it suitable for use in most household and industrial applications.
Additionally, the axial leads of the fuse are made of tin-plated copper wires, providing excellent conductivity and corrosion resistance. This allows for efficient and reliable current flow, ensuring the proper functioning of the protected equipment or system.
The Miniature Cartridge Fuse offers the following key features:
With its compact size and reliable performance, the Miniature Cartridge Fuse is an ideal choice for protecting sensitive electronic equipment and ensuring the safety and stability of electrical systems.
Product Name | Miniature Cartridge Fuse |
---|---|
Operating Temperature | -55℃ To +125℃ |
Axial Leads | Tin-plated Copper Wires |
Rated Current | 250mA-16A; 12.5A-16A; 1A-15A |
Rated Voltage | 250V AC |
Storage Conditions | +10℃ To +60℃ |
Standard | IEC 60127-2/Ⅱ; GB/T9364.7 |
Main Characteristics | Miniature Cartridge Fuse; Fast-Acting(F) |
Fast acting | Glass Tube |
End Caps | Nickel-plated Brass |