Product Performance and Principle
The KSD305 temperature controller produced by our company is a single-pole single-throw temperature controller with a bimetallic temperature-sensing jump. The controller is divided into two types of automatic and manual reset by an insulating shell, a metal cover, a bimetal, a contact bridge, a spring, and an action rod, which constitute a unipolar normally closed switch. When the temperature change increases and reaches the preset deformation temperature of the bimetallic strip, the bimetallic strip operates to separate the contact bridge from the contact through the actuating rod, so that the switch that was originally in a normally closed state is disconnected. The cut-off temperature can be made according to the customer's needs. After the action, it needs to be manually reset to make it closed; automatic reset. When the temperature rises to the action temperature, the power is turned off and the temperature will drop. When it drops to the reset temperature, the temperature control will be closed. power ups.
Product name | Thermostat | ||||||||||||
Model | KSD305 | ||||||||||||
Rated electrical performance | AC250V/50HZ,≤30A(Resistive load) | ||||||||||||
Normal electric strength | AC50Hz1250V/1min No breakdown and flashover phenomenon | ||||||||||||
Normal insulation resistance | >300MΩ | ||||||||||||
Contact form | SPST (Single pole single throw) | ||||||||||||
Normal closed | The temperature rises and the contacts open | ||||||||||||
Life cycles | 6000 times | ||||||||||||
Action temperature | 50℃-140℃ | ||||||||||||
Temperature tolerance | +/-3℃,+/-5℃(According to customer needs) | ||||||||||||
Temperature sensing material | Bimetallic materials:TP140-80,B1,PA721,E3 | ||||||||||||
Connection method | Fastening screw lock | ||||||||||||
Contact material | Copper composite silver(T2+AgNi10) | ||||||||||||
Insulation materials | Phenolic PF2A-151J(b) | ||||||||||||
Structure | Built-in | ||||||||||||
Enclosure protection class | IP00 | ||||||||||||
Insulation material PTI value | PTI175 | ||||||||||||
Heat and flame resistance classification | B type |
Notes
Adopt contact temperature-sensing installation, so that the metal cover plane is close to the installation surface of the heating element during installation. Do not collapse and deform the cover surface during installation, so as not to affect performance.
Do not allow liquid to penetrate into the thermostat during use, so as not to affect the electrical reliability and prevent leakage damage. This product is a single-pole connection method. When using it, it should be connected correctly according to the identification symbol. The rated current used cannot be greater than 30A.
Products should be stored in a ventilated, clean, dry, and non-corrosive warehouse with a relative humidity of less than 90% and an ambient temperature of 40°C.
Scope of Application
It is suitable for electric water heaters, electric heating equipment, electric welding machines, steam generators and other high-power electrical appliances that require overheating protection.
Wiring Diagram
Temperature characteristics comparison table (see the table below):
Action temperature | Reset temperature | Action temperature | Reset temperature |
20±5℃ | 5±10℃ | 125±5℃ | 95±15℃ |
30±5℃ | 10±10℃ | 130±5℃ | 100±15℃ |
45±5℃ | 40±10℃ | 135±5℃ | 105±15℃ |
50±5℃ | 40±10℃ | 140±5℃ | 110±15℃ |
55±5℃ | 45±10℃ | 145±5℃ | 115±15℃ |
60±5℃ | 50±10℃ | 150±5℃ | 120±15℃ |
65±5℃ | 50±10℃ | 155±5℃ | 125±15℃ |
70±5℃ | 50±10℃ | 160±5℃ | 130±15℃ |
75±5℃ | 55±10℃ | 165±5℃ | 135±15℃ |
80±5℃ | 55±10℃ | 170±5℃ | 140±15℃ |
85±5℃ | 55±10℃ | 175±5℃ | 145±15℃ |
90±5℃ | 60±10℃ | 180±5℃ | 150±15℃ |
95±5℃ | 65±10℃ | 185±5℃ | 160±15℃ |
100±5℃ | 75±10℃ | 190±5℃ | 165±15℃ |
105±5℃ | 80±15℃ | 200±5℃ | 170±15℃ |
110±5℃ | 80±15℃ | 210±5℃ | 175±15℃ |
115±5℃ | 85±15℃ | 215±5℃ | 180±15℃ |
120±5℃ | 90±15℃ | 220±5℃ | 185±15℃ |
The exterior shape and dimensions of the product