ALL- IN - ONE Hybrid solar inverter charger for home 12V35A1000W with Temperature compensation
Energier Apollo charge controller can be used in multiple applications. It can compose power backup system, or with a quick setting, it can compose a simple solar hybrid system either with grid or diesel generators.
PWM version 1.2KW-1.7KW
MPPT version 2KW-4KW
Energier Apollo has some distinguished features designed especially for African, Middle East and
South East Asian countries where the grid was not stable and low voltage was frequently
encountered. Energier Apollo can maximize the usage of grid and automatically adjust its charging
in accordance with the setting
Specifications
INVERTER
Three Working modes: Weak grid/Solar hybrid/ Solar energy storage
Nominal Voltage: 12VDC
Power 30mins @25℃(VA):1000
Power 30mins @25℃(W):900
Cont. power @25℃( VA) 【1】:800
Cont. power @25℃( W):750
Cont. power @40℃( W):700
Output voltage【2】:230 VAC / 110 VAC ± 2%
Output frequency :50 / 60 Hz ± 0.1%
Cos φ:0.9-1
Overload Capability【3】:>125% 60S
Overload Capability【3】:>150% 20S
Surge:300%
Efficiency (MAX.):90.5%
Bypass range: Weak Grid 168 VAC - 276 VAC / 84 VAC -138 VAC
Bypass range: Standard 184 VAC - 264 VAC / 92 VAC -132 VAC
THD 【4】:<3%
CHARGER
Nominal Output Voltage:12VDC
Max Output current (A) - adjustable:35A
AC Input range: Weak Grid 168 VAC - 264 VAC / 84 VAC -132 VAC
AC Input range: Standard 184 VAC - 264 VAC / 92 VAC -132 VAC
Battery types:AGM / GEL(OPzV) / LFP / Flooded
Temperature compensation:-4mV / ℃ / cell
SOLAR CHARGE CONTROLLER
Max PV open circuit voltage (Voc):25 VDC
Recommended PV (Vmpp):16-19VDC
Current max:50A
PV Fuse:40AX2
PV input terminal:MC4X2
Other Data
Typical transfer time: 8ms
DC Fuse 40AX4
Transfer switch 16A
Dimension (mm) (max): 470×233×95
Enclosure:Steel with powder paint
Net Weight (KGs):10.5
Safety EN62109-1 , EN62109-2
EMC: EN61000-3-2,EN61000-3-3,EN61000-6-1,EN61000-6-3
Remarks:
【1】None linear load, crest factor 3:1
【2】Output voltage: 220 VAC / 60Hz for Philippines
【3】Base on Cont. power @25℃
【4】linear load, crest factor 1.4:1
Accessory( Optinal)
- RCH
- Cyber
Monitoring : with all real time data Battery State of Charge
Digiital Shun: Digital shunt features microprocessor controlled combined with high resolution measuring system for battery voltage and charge/discharge current. With built in software,it can Apart from discharging and charging, multiple other factors are considered including battery size, age ratio of battery etc. With shunt,
TS