Combined with modern semiconductors and a patent pending control algorithm, TP600-1U inverter could achieve a compact size within the 19”1U height.
- Rated power: greater than or equal to 1KVA.
- Architecture: "Stand alone" rackable in 19 ".
- automatic bypass: the equipment have 48VDC and 220VAC inputs so that in the event of an operational input failure, the equipment transfers load to the alternate input automatically, and the interruption or disturbance in the output must last less than or equal to 8ms. The team have the ability to choose from which input the load will be fed. In the case where the load is fed through the AC input, the equipment must have a filter against electromagnetic interference in order to improve the output waveform.
- Control by keyboard and front screen, should include:
• Real-time measurements of input and output values (voltages,
currents and frequencies).
• Alarms.
• Choice of input source (DC or AC).
Event Log: The controller have a history record of events, informing the date and time of their appearance and disappearance from them.
Here are the Features;
- 19”1U or 19”2U
- High Frequency standby design with
- Transfer time 5-8ms
- Working mode selectable (AC priority or DC priority)
- High Frequency design
- DC/AC isolation improving system security
- Complete protection
- Thermal controlled fan
- RS232 or RS485 communication port and Dry point
- Voltage adjustable 230Vac (200-240) or 110Vac (100-120)
- Front panel connection version available
- System parameters programmable
LED shows
Specifications
TP600D and TP600E (110VDC/220VDC models)
Model | TP605 | TP610 |
Electrical | ||
DC input | 110Vdc or 220Vdc | |
Dc input range | .-17% ~ +25% | |
AC Input | ||
AC input | 230Vac or 110Vac (-25%~+20%) | 230Vac (-25%~+20%) |
Frequency range | ±10% | |
Output power | 500va | 1kva |
Wave form | Pure sine wave | |
Power factor | 0.8 | |
Norminal output voltage | 230Vac or 110Vac | 230Vac |
Voltage variation | Max ± 2% | |
Output frequency | 50/60Hz ± 0.1Hz | |
Efficiency | Max 90% | |
THD | <3% liner load | |
<5% non-liner load | ||
Crest factor | .3:1 | |
Overload | 125% 60secs | |
110% 10mins | ||
Transfer time | 5-8ms | |
Dynamic response time | < 30ms | |
LVD | 91.5Vdc or 183Vdc | |
Display & Communication | ||
LED indicator | Working mode, Fault info | |
Communication Interface | RS232 and RS485 | |
4xDry contact | ||
Safety & Enviroment | ||
Operating Temp. | Full load, <-20℃> - 40℃ | |
Derating using, 40℃ - 60℃ | ||
Isolation | 2000Vrms | |
Mechanical | ||
Dimension (WxH) | 19"1U | |
Depth | 319mm | |
Weight | 4.0kgs/4.5kgs | |
Cooling | forced fan with thermal control | |
Enclosure | IP20 | |
Standard | ||
LVD | EN60950-1 | |
EMC | EN55022 |