Electrical Wring Cable Ul 2103 Pvc Insulated And Jacketed Muti-Core Tinned Copper Shielding Electrical Power Wire
1.Product name:UL2103
2.Rated temperature:105℃
3.Rated voltage:300V
4.Reference standard:UL758,UL1581
5.Conductor: Solid or Stranded Bare Copper/Tinned Copper
6.Insulation material: PVC
7.Shield:Tinned or bare copper wire braid
8.Passes UL Horizontal &CSA FT2 flame test
9.Uniform insulation thickness to ensure easy stripping and cutting.
10.For internal wiring of appliances.
Suitable for use as a command,measuring and control cable in tool making machinery conveyor system and production lines,in industrial plants and in air conditioning as well as in the steel producing industries.
Construction
Conductor:Tinned copper,fine wire conductors
Insulation:Special PVC conre insulation
Assembly:Two or more singles,twisted pairs of groups of twisted singles twisted together of singles or goups of singles may be laid parallel to form flat,oval or round cable.
Covering:optional
Shield:optinal
Jacket:extruded PVC
Covering:Extruded PVC
High Quality Ul2464 Ul2516 Ul2517 Electronic Cable
Technical data
Rated temperature: 80°C
Nominal voltage: 300V
Test voltage: 2000V
Bending radius once approx. 5×coreø multiple approx. 10×coreø
Properties
Conditionally resistant to oils,solvents,acids,lyes
PVC self-extinguishing and flame retardant,test method to UL VW-1/CSA FT1
The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers.
Assembly | Consists of two or more singles, twisted pairs or groups of twisted singles twisted together. The singles or groups of singles may be laid parallel forming a flat, oval or round cable. The lay of the conductors are not specified. A barrier layer and/or fillers are optional. Manufacturer shall maintain a complete description of each assembly. May use same or mixed AWG size. |
Product Parameters
ULTYPE | CONDUCTOR | INSULATION | SHIELD (mm) | JACKET | MAX.COND. RESISTANCE (Ω/kft) | |||||
(No.) | AWG | CONSTRUCTION | DIA.(mm) | insulation thickness(mm) | O.D.(mm) | sheath thickness (mm) | O.D.(mm) | |||
(NoTmm) | ||||||||||
UL2517 | 2 | 26 | 7/0.16 | 0.48 | 0.38 | 1.3 | 0.2 | 0.76 | 4.6 | 45.8 |
24 | 11/0.16 | 0.61 | 1.4 | 4.8 | 28.7 | |||||
22 | 17/0.16 | 0.76 | 1.6 | 5.2 | 18.1 | |||||
20 | 21/0.178 | 0.94 | 1.8 | 5.6 | 11.2 | |||||
3 | 26 | 7/0.16 | 0.48 | 1.3 | 4.8 | 45.8 | ||||
24 | 11/0.16 | 0.61 | 1.4 | 5 | 28.7 | |||||
22 | 17/0.16 | 0.76 | 1.6 | 5.5 | 18.1 | |||||
20 | 21/0.178 | 0.94 | 1.8 | 5.9 | 11.2 | |||||
4 | 28 | 7/0.127 | 0.38 | 1.2 | 4.9 | 72.8 | ||||
26 | 7/0.16 | 0.48 | 1.3 | 5.2 | 45.8 | |||||
5 | 28 | 7/0.127 | 0.38 | 1.2 | 5.3 | 72.8 | ||||
26 | 7/0.16 | 0.48 | 1.3 | 5.5 | 45.8 | |||||
6 | 28 | 7/0.127 | 0.38 | 1.2 | 5.6 | 72.8 | ||||
26 | 7/0.16 | 0.48 | 1.3 | 5.9 | 45.8 | |||||
7 | 28 | 7/0.127 | 0.38 | 1.2 | 5.6 | 72.8 | ||||
26 | 7/0.16 | 0.48 | 1.3 | 5.9 | 45.8 |