Features:
lDual wall insulation, Electron beam cross-linked
Excellent resistance to U.V., water, ozone, fluids, salt, general weathering
lExcellent resistance to abrasion
Halogen free, flame retardant, low toxicity
Excellent flexibility and stripping performance
High current carrying capacity
TUV and UL approved
Fire Resistant Cables PV-1X4mm2 High Standard Specification:
Construction | Conductor construction. | Conductor | Outer | Resistance Max. | Current Carring Capacity | ||||
nxmm2 | n/m | mm | mm | Ω/Km | A | ||||
1X1.5 | 30/0.25 | 1.58 | 4.90 | 13.30 | 30 | ||||
1x2.5 | 50/0.25 | 2.02 | 5.45 | 7.98 | 41 | ||||
1x4 | 56/0.3 | 2.30 | 6.10 | 4.75 | 55 | ||||
1x6 | 84/0.3 | 3.42 | 7.20 | 3.39 | 70 | ||||
1x10.0 | 142/0.3 | 4.56 | 9.00 | 1.95 | 98 | ||||
1x16.0 | 228/0.3 | 5.60 | 10.20 | 1.24 | 132 | ||||
1x25.0 | 361/0.3 | 6.95 | 12.00 | 0.795 | 176 | ||||
1x35.0 | 525/0.3 | 8.74 | 13.80 | 0.565 | 218 | ||||
1x50.0 | 720/0.3 | 9.20 | 14.80 | 0.393 | 280 | ||||
1x70.0 | 988/0.3 | 11.00 | 16.90 | 0.277 | 350 | ||||
1x95.0 | 1349/0.3 | 12.50 | 18.70 | 0.21 | 410 | ||||
1x120.0 | 1691/0.3 | 14.20 | 20.70 | 0.164 | 480 |