PZT Powder of P-33 Navy Type I Soft Material For Receiving Function
The material performance of piezoelectric ceramic | ||||||||||
Num | Name of Performance parameter | symbol | index | Allow the public errand | ||||||
P-33 | P-44 | P-51 | P-81 | |||||||
1 | Electromechanical coupling coefficient | Kp | 0.60 | 0.60 | 0.65 | 0.53 | ±6.0% | |||
K31 | 0.36 | 0.36 | 0.38 | 0.31 | ||||||
K33 | 0.70 | 0.70 | 0.74 | 0.63 | ||||||
K15 | 0.70 | 0.70 | 0.72 | 0.66 | ||||||
Kt | 0.47 | 0.48 | 0.50 | 0.47 | ||||||
2 | The relative electric capacity rate of freedom |
|
1725 | 1350 | 2100 | 1025 | ±12.5% | |||
|
1725 | 1900 | 2400 | 1400 | ||||||
3 | The medium losses | tgδ | 0.020 | 0.005 | 0.020 | 0.004 | ≤ | |||
4 | The gentle and agreeable constant of elasticity (x10-12m2/N) |
|
15 | 13 | 15 | 11.0 | ±10% | |||
|
9.0 | 8.5 | 9.0 | 8.5 | ||||||
|
25 | 21.5 | 22.0 | 21.0 | ||||||
5 | Piezoelectricity meet an emergency the constant (x10-12m/v或C/N) |
d31 | 160 | -150 | -210 | -100 | ±12.5% | |||
d33 | 390 | 320 | 450 | 225 | ||||||
d15 | 480 | 530 | 710 | 450 | ||||||
6 | Mechanical cue | Qm | 75 | 400 | 70 | 800 | ≥ | |||
7 | Frequency constant (Hz•m) |
Nd | 1950 | 2200 | 2000 | 2300 | ±5% | |||
N1 | 1470 | 1600 | 1450 | 1700 | ||||||
N3 | 1880 | 2000 | 1900 | 1960 | ||||||
N5 | 1130 | 1230 | 1200 | 1230 | ||||||
Nt | 2250 | 2300 | 2250 | 2280 | ||||||
8 | The velocity of sound (m/s) |
Vd | 3000 | 3300 | 3000 | 3500 | ±5% | |||
V1 | 2940 | 3200 | 2900 | 3400 | ||||||
V3 | 3760 | 4000 | 3800 | 3920 | ||||||
V5 | 2260 | 2460 | 2400 | 2460 | ||||||
Vt | 4500 | 4600 | 4500 | 4560 | ||||||
9 | Density (x103kg/m3) | ρ | 7.6 | 7.5 | 7.45 | 7.45 | ≥ | |||
10 | Curie's temperature (℃) | Tc | 335 | 300 | 260 | 300 | ≥ | |||
11 | Rate of change of time of ten times (%) |
ANd | 0.20 | 1.2 | 0.35 | 1.3 | ||||
AKp | -0.25 | -1.8 | -0.4 | -2.0 | ||||||
Aε | -1.5 | -4.0 | -1.5 | -4.0 | ||||||
12 | The relative rate of change of temperature (%)-10℃~50℃ The datum 25℃ | ΔNd/N | 1.0 | 1.0 | 1.5 | 1.5 | ||||
Δε/ε | 15 | 9.0 | 20 | 9.0 | ||||||
13 | The strong field lies between electric performance T=25℃ E=400V |
tgδ | 0.04 | 0.01 | ≤ | |||||
Δε/ε | 0.17 | 0.06 | ≤ | |||||||
note: 1, Index besides Curie's temperature, is the measurement value for ten days after polarizing for the performance parameter index in the form . |
FAQ:
Q: how can we guarantee quality?
Always a pre-production sample before mass production;
Always final Inspection before shipment;
Q: what can you buy from us?
Ultrasonic Transducer,Ultrasonic Equipment,Piezoelectric Ceramic,Ultrasonic Generator,ultrasonic equipment parts
Q: why should you buy from us not from other suppliers?
The company has more than ten years of experience in design and development, product variety, wide range of applications, large-scale production, rapid delivery, quality system improvement, process control is guaranteed.
Q: How soon can we get the detailed quotation?
Firstly please kindly tell us the size, material and demand quantity, your drawing with technical requirements is best.
If you only have samples, you can also send us.
We will quote our best price in 24 hours, for simple items, we will quote in 1 hour.
Q: what services can we provide?
Accepted Delivery Terms: FOB;
Accepted Payment Currency:USD,EUR,JPY,CAD,AUD,HKD,GBP,CNY,CHF;
Accepted Payment Type: T/T;
Language Spoken:English,Chinese