High-precision Paper Testing Equipments integrating sphere spectro photometer
Product Features:
portable integrating sphere spectrophotometer, and its versatile performance can be used for various practical applications.
★ portable, compact, lightweight and stylish body.
★ Chinese display operation, high-precision sensors.
★ with CM-2600d (Ø8) and CM-2500d compatible data.
★ store up to 1700 sets of data.
Usage
Suitable for plastic / rubber, paint, textile dyeing, printing, leather, automobile and so on. Color quality management software can connect, CCM (computer color matching system).
Technical Specifications:
Light / Observing System | d / 8 (light scattering, 8 degree viewing angle) with SCI (specular component included) / SCE (not including specular reflection) synchronous measurement function. (Meet CIE No.15, ISO 7724/1, ASTME1164, DIN5033 Tei17, JIS Z8722 Condition c standards.) |
Integrating sphere size | Ø52mm |
Sensor | silicon photodiode array (dual 40 elements) |
Splitting means | Diffraction grating |
Wavelength Range | 360nm-740nm |
Wavelength spacing | 10nm |
Spectral half band width | 10nm |
Reflectance range | 0-175%, resolution: 0.01% |
Light source | 2 pulsed xenon lamp |
Measuring time | Approximately 1.5 seconds |
Minimum measurement interval | 3 seconds (at 23 ℃) |
Battery performance | At 10-second intervals of about 1000 times (with alkaline batteries) (at 23 ℃) |
Measurement / illumination area | Ø8mm/Ø11mm |
Repeatability | Spectral reflectance: Standard deviation less than 0.2% (360 to 380nm: standard deviation of 0.4% or less) Chromaticity value: Standard deviation within ΔE * ab 0.08 (after correction on the board at 10-second intervals white calibration plate is measured 30 times) |
Phase difference | ΔE * ab of 0.4 or less (SCI) (based on 12 BCRA Series ll whiteboard, on average, when compared at 23 ℃ was measured by the host body values) |
Language patterns | English / Chinese |
Measurement mode | Single / average (Auto mode: 1-8 times / manual mode) |
Port | Meet the RS-232C standard |
Observer | 2/10 degrees |
Observation light source | A, C, D50, D65, F2, F6, F7, F8, F10, F11, F12 (using two light sources can be calculated simultaneously) |
display | Spectral values / charts, color values, color values, "pass / fail" decision, the relative gloss |
Color space / colorimetric data | L*a*b*,L*C*h,Yxy,XYZ,MI,ΔE*ab,CMC(1:1),CMC(2:1),CIE94,CIE DE2000,WI(ASTM E313),YI(ASTM D1925)
|
Data sets can be stored | 1,700 (each data set by a pair of SCI / SCE data members) |
Tolerance judgment | Chroma Tolerance |
Power supply | AA batteries (X 4), AC adapter |
Size | 69 (W) X96 (high) X193 (L) mm |
Weight | Approximately 670g (including whiteboard / batteries not included) |
Operating temperature / humidity range | 5 ℃ to 40 ℃, relative humidity 80% or less (at 35 ℃), without condensation |
Storage temperature / humidity range | 0 ℃ to 45 ℃, relative humidity 80% or less (at 35 ℃), without condensation |
Standard accessories | White Calibration Plate: CM-A145 |
Ø8mm Target box: CM-A146 | |
RS-232C cable (D-sub9-pin, for IBM, PC / AT): IF-A16 | |
AC Adapter AC-A17 | |
AA (R6) alkaline batteries X 4 | |
Optional accessories | Zero Calibration Box: CM-A32 |
Hard Carton: CM-A148 | |
Dust Cover Kit: CM-A149 | |
Cover: CM-A152 | |
Color Data Software "SpectraMagic NX": CM-S100W | |
Printer cable (D-sub9 pin for serial link): CR-A75 |