Flame Temperature Calibration Device
Description:
This calibration device is designed in accordance with IEC 60695-11-5 and GB/T 5169.5 standards for measuring the flame temperature of needle flame test instruments.
During measurement, the copper block is positioned 6±0.5mm above the needle flame burner. The flame is ignited, and the time required for the copper block temperature to rise from 100°C±5°C to 700°C±3°C must be within 23.5±1.0 seconds.
Three measurements are required, with natural cooling of the copper block to below 50°C between each test.
Note: Thermocouples are susceptible to damage above 700°C; thus, the burner must be removed immediately upon reaching this temperature.
Reference Standard:
IEC 60695-11-5: Fire hazard testing — Part 11-5: Test flames — Needle flame test method — Apparatus, confirmatory arrangement and guidance.
GB/T 5169.5: Test flames — Needle flame test method — Apparatus, confirmatory test arrangement and guidelines.
Technical Parameters:
Model | 6010-HD |
Thermocouple | Armored K-type (NiCr/NiAl) fine-wire thermocouple with a 0.5mm diameter sheath. |
Timer | Adjustable range: 0.01–99.99 seconds. |
Copper Block Specifications | |
Diameter | Ø4.00±0.01mm |
Length | 6.00±0.03mm |
Bevel Angle | 45 degrees (both ends) |
Mass (Pre-drilling) | 0.58g±0.01g |
Material | High-conductivity electrolytic copper |
Surface Finish | Fully polished |
ABOUT HAIDA
Why choose us?
1.Design & Production : Solution Consultation for each order
Recommend the most cost -performance machine
Research & Develop the suitable one for Special- designed Model.
2.Shipping & Delivery: One-Stop Service
Production- Deliver to your door - Installation & Training- Technical Support
3.Warranty
1 year warranty with lifetime technology support
4.After-Sale Service
React within 2 Hours
Video inspection & on-site service combined
FAQ
Q: How about your warranty?
Q: What is the order process?
Q: Can we visit your factory before order?
Q: Do you accept customization service?