fuel station diesel tank volume monitor control system PC software for gasoline tank level volume automatic tank gauge
Gas station safety monitoring SYSTEM SOFTWARE
we can provide the oil inlet,sale and storage one-stop management solution for gas station , and he can make magnetostrictive level gauge,unloading overflow system,double-layer pipe leakage detector ,double-layer tank leakage detector,tank car vehicle-mounted level gauge,high level alarm,combustible gas alarm ,oil-submerged,Explosion-proof alarm to achieve integrated control. Real-time monitoring tank storage information,temperature,oil tank and pipe-leak detector,oil discharge records,gas concentration alarm,shift exchange information. Users can query the remotely by network ,user can make the unified management for his gas station .
Gas station level gauge
1.Gas station level gauge consist of SYW-A magnetostrictive probe and touch control console (TCM-1,TCC-2,TCC-3).
2.SYW-A magnetostrictive probe installed in the tank,take the magnetostrictive technology,can accurately measure the inner tank oil level ,water level and multiple temperature;
3.Touch control console installed in the control room, it can automatically probe data acquisition and processing, real-time display can tank storage information, realize the tank leak detection, automatic unloading, record query, control multi-channel submersible pump,oil level alarm, data upload, and other functions.
picture
SYW-A Magnetostrictive sensor Probe
1,The probe consist of:
Fully enclosed magnetostrictive probe.
Electronic Pod using for data measuring and transforming.
Floater made according to the product.
2,Features:
Safety: ExiaIIBT4 (Intrinsically safe) issued by PCEC
Accuracy: level accuracy is ±0.3mm
Stability: strong anti-jamming ability
Efficiency: less than 1 second to test one tank.
3,Probe Performance
Item | SYW-A |
Purpose | To measure product level, water level and temperature |
Titles of medium | Gasoline, diesel, kerosene, ethanol , water etc. |
State of medium | Liquid |
Explosion-proof grade | ExiaIIBT4 (Intrinsically safe) |
Pressure range | -0.02Mpa~0.6Mpa |
Certificate | PCEC Conformity Certificate of Explosion-proof / Permit of Manufacture Measuring Instruments |
Temperature | -40℃~70℃ |
Product Level Accuracy | ±0.3mm |
Water Level Accuracy | ±0.3mm |
Temperature Accuracy | ±0.2℃ |
Height Resolution | 0.023mm |
Repeatability | ±0.1mm |
Environmental Temperature Effect | Error<0.2mm |
Vibration Effect | Error<0.5mm |
Lowest Product Inactive Zone | 2.5'' floater-180mm |
Lowest Water Inactive Zone | 2.5'' floater-25mm |
Measured Variable | Product level, interface level and temperature of 5 sensors and average temperature |
Probe Length | 600~3500mm |
Method of Communication | RS-485 |
Probe Material | 1Cr18Ni9Ti |
Power Supply | +24~26VDC |
Protection Class of Probe Canister | IP67 |
Max Communication Distance | 1200m |
picture :
TCM-1 Touch Control Console
TCM-1 Touch Control Console
Specification
Items | Performance index |
L×W×H | 400mm×300mm×200mm |
Supply Voltage | AC 120V~265V 50Hz |
Ambient Temperature | -10℃~+60℃ |
Ambient Humidity | 20%~85% |
Screen Dimension | 7 Inch |
Display Mode | English,graphic,LCD |
Monitor up to | 1~16 |
Transmission Mode with Central Control System | RS-232 (within 15m) |
Transmission Mode with Magnetostrictive probe | RS-485 (within 1200m) |
Picture :