GUIHE factory petrol station underground tank fuel level monitor ATG automatic tank gauge
1. high accuracy guihe fuel tank level monitor system ATG automatic tank gauge
2. automatic tank gauge include SYW-A magnetostrictive probe + TCM-1 touch control console +PC software
3. automatic tank gauge include SYW-A magnetostrictive probe detail :
A,The probe consist of:
Fully enclosed magnetostrictive probe.
Electronic Pod using for data measuring and transforming.
Floater made according to the product.
B,Features:
Safety: ExiaIIBT4 (Intrinsically safe) issued by PCEC
Accuracy: level accuracy is ±0.3mm
Stability: strong anti-jamming ability
Efficiency: less than 1 second to test one tank.
C,Probe Performance
Item | SYW-A |
Purpose | To measure product level, water level and temperature |
Titles of medium | Gasoline, diesel, kerosene, ethanol , water etc. |
State of medium | Liquid |
Explosion-proof grade | ExiaIIBT4 (Intrinsically safe) |
Pressure range | -0.02Mpa~0.6Mpa |
Certificate | PCEC Conformity Certificate of Explosion-proof / Permit of Manufacture Measuring Instruments |
Temperature | -40℃~70℃ |
Product Level Accuracy | ±0.3mm |
Water Level Accuracy | ±0.3mm |
Temperature Accuracy | ±0.2℃ |
Height Resolution | 0.023mm |
Repeatability | ±0.1mm |
Environmental Temperature Effect | Error<0.2mm |
Vibration Effect | Error<0.5mm |
Lowest Product Inactive Zone | 2.5'' floater-180mm |
Lowest Water Inactive Zone | 2.5'' floater-25mm |
Measured Variable | Product level, interface level and temperature of 5 sensors and average temperature |
Probe Length | 600~3500mm |
Method of Communication | RS-485 |
Probe Material | 1Cr18Ni9Ti |
Power Supply | +24~26VDC |
Protection Class of Probe Canister | IP67 |
Max Communication Distance | 1200m |
4. automatic tank gauge include TCM-1 touch control console
TCM-1 Touch Control Console
Specification
Items | Performance index |
L×W×H | 400mm×300mm×200mm |
Supply Voltage | AC 120V~265V 50Hz |
Ambient Temperature | -10℃~+60℃ |
Ambient Humidity | 20%~85% |
Screen Dimension | 7 Inch |
Display Mode | English,graphic,LCD |
Monitor up to | 1~16 |
Transmission Mode with Central Control System | RS-232 (within 15m) |
Transmission Mode with Magnetostrictive probe | RS-485 (within 1200m) |
The main functions is as follows:
*Authority Management: It’s only need a password to enter the Parameter Setup and Manual Control, others free operation.
*Parameter Setup: Customers can setup parameters about tank, time and tank volume table.
*Auto-monitoring: Monitoring up 1~12 (max 16) tanks, display all the tank real time information.
*Automatic Gauge: Display fuel level, density, temperature, inventory and ullage, monitor the fuel delivery condition of real time. Display dynamically the change of fuel level with graphic and scale.
*Inventory Report(Previous Records): Users can visit /print/copy the inventory at any moment
*Tank Volume Table Edition: Users can input or modify the tank volume table from computer.
*Alarm: High fuel level alarm, low fuel level alarm, fuel temperature upper limit alarm, fuel temperature lower limit alarm. With audible and visual alarm signal, audible alarm can be removed. It can connect with an outside explosion-proof ringer to avoid the fuel spilled.
*Parameter Setup: Users can setup the tank parameter, time parameter, keyboard size and interval of inventory records.
*Shift Exchange: Click the working team you want.
*Data Export: Export tank information toU disk.
5. automatic tank gauge Picture