CMS9000 Plus Veterinary Patient Monitor 6 Parameter ECG / RESP / TEMP / SpO2 / PR / NIBP
The monitor structure is divided into portable, mainly by the host (including software) and accessories, including the host by the display part and ECG, noninvasive blood pressure, blood oxygen saturation, body temperature, breathing, pulse and other monitoring unit composition, Electric electrodes, ECG lead, oxygen probe, body temperature sensor, blood pressure cuff, blood pressure extension cord. This patient monitor is veterinary type that special for anima test.
Six parameters | ECG,HR,SPO2,NIBP,RESP, TEMP |
display | 12.1 inch |
Leads | 3-5 leads |
Suitable use places | hospital |
Working system | Continuous running equipment |
Type | Veterinary |
Color: | White |
Technical parameters
ECG measurement:
Leads choices: All, I, II, III, aVF, aVR, aVL. V1--6 chest leads showed
Gains options: × 1, × 2, × 0.25, and ×0.5 four trenches
Frequency: 0.5 Hz - 100 Hz
Common-mode signal inhibition: More than 70 dB
Scan rate: 12.5 mm / S, 25 mm / S, 50 mm / S standard three stalls.
HR: ± 5 bpm
Precision calibration signal: 1mv(peak, ± 3% accuracy)
ST Detection: measurement range (-1.0mV----+1.0mV)
Using Standard: meet the ANSI / AMI EC13 -2002 standard
Response time: 1s
Alarm: Sound and Light
Preset heart rate range: (Alarm over preset numerical)
Ceiling: 1-255 bpm adjustable
Threshold: 0-254 bpm adjustable
NIBP measurement
Technology: Oscillography
Mode: manual / automatic
Measurement units: mmHg / kPa
Protection: Double security protection
A measurement time: less than 45 S
Scope: Pressure Cuffs 0-250 mmHg
Blood pressure measurement accuracy: ANSI /AAMI, SP10-2002 standard error and standard deviation of the average value of the initial
Inflatable cuffs: 180 mmHg (children 120mmHg)
Inflatable cuffs follow: original SBP: + 30 mmHg
Blood pressure measuring range:
Systolic blood pressure: 60-250 mmHg
Diastolic blood pressure: 40-220 mmHg
Pressure on the average: 45-235 mmHg
Response time: 1s
Alarm: Sound and Light
Preset range: report (Numerical exceed preset alarm)
Systolic blood pressure maximum: 1-255 mmHg adjustable
Threshold: 0-254 mmHg adjustable
Diastolic blood pressure ceiling: 1 -255 mmHg adjustable
Minimum standards: 0-254 mmHg adjustable
Use standard: compliance with the ANSI / AAMI SP10-2002 standard
Spo2 measurement
Range: 0-100%
Accuracy: 1%
Resolution: 1%
Pulse frequency: 20-250 times / min
Response time: 1s
Alarm: Sound and Light
Preset range: (report Alarm over preset numerical)
Ceiling: 1% - 100% adjustable
Threshold: 0% - 99% adjustable
TEMP measurement:
Technology: thermostat temperature probe
Measuring range: 20 ° C-45 ° C
Temperature resolution: 0.1%
Accuracy: ± 0.1 ° C
Response Time: 1s
Alarm: Sound and Light
Preset range: report (numerical preset alarm over)
Maximum: 20.1 ° C-45.5 ° C adjustable
Threshold: 20 ° C-45.4 ° C Adjustable
RESP Breath
Breathing frequency range: 0-60 bum
Accuracy: ± 1rpm
Response time: 1s
Gains options: × 1, × 2, × 4, and × 0.5 four trenches
Alarm: Sound and Light
Alarm range: (numerical preset alarm over)
Ceiling: 10-100 bpm adjustable
Threshold: 0 -99 bpm adjustable
Printer(Optional)
Specification: Dual channel thermal array data recorder
Print mode: Real time or event triggered record waveform and text
Accuracy: horizontal: 4oodpi vertical: 800dpi
Annotation: Date/ time(24 hours)
Optional wall bracket, mobile stand, visits backpack.
System
Screen:12.1 inches TFT screen of LCD
Battery: lead acid
Safety standard: lec601-1(GB9706.1)