Explosion proof fail safe electric actuator with small package / installation at any angle
Features:
Description
DCL-Ex series fire safe electric actuators are fail safe. When backup power is on after explosion, the actuator can drive to pre-setting position such as full open or full close, even input control signal is not available. Self-locking function can also keep valve at last known position without hunting. Actuators can be used for over 90% explosive gas environment, except for colliery. Over 10000 DCL anti-explosion actuators have safely worked for over 10 years.
Actuators are under tests hold by CSA office for both Zone and Division system per UL and CSA standard. ATEX is obtained. CE and RoHS 3 are tested by SGS.
Specification
Type | Ex05E | Ex10E | Ex20E | Ex40E | Ex60E |
Power | AC110V/AC220V | ||||
Output Torque | 50Nm | 100Nm | 200Nm | 400Nm | 600Nm |
Acting Time | 20S | 30S | 30S | 30S | 45S |
Turning Angle | 0-90° | 0-90° | 0-90° | 0-90° | 0-90° |
Motor Power | 10W | 25W | 40W | 90W | 90W |
Rated Current | 0.24/0.15A | 0.57/0.30A | 0.63/0.35A | 1.12/0.64A | 1.18/0.67A |
Total Weight | 3.0kg | 5.0kg | 5.5kg | 9.5kg | 10.0kg |
Input Signal | 4-20mADC,1-5VDC,2-10VDC | ||||
Output Singal | 4-20mADC | ||||
Basic Error | not more than ±1% | ||||
Reciprocating Error | not more than 1% | ||||
Dead Space | 0.5%-5.0% adjustable | ||||
Damping Characteristic | 0 times | ||||
Repeating Error in Actuator | ≤1% | ||||
Insulating Resistance | 100MΩ/500VDC | ||||
Withstand Voltage Class | 1500VAC 1minutes | ||||
Protection Class | IP67 | ||||
Explosive-proof grade | Exd II BT4Gb | ||||
Installation Angle | 360°at any angle | ||||
Electric Interface | 2-M20*1.5 explosion-proof plug,clients should install corresponding explosion-proof cable connector when using according to the cable selected. | ||||
Ambient Temperature | -20℃~+60℃ | ||||
Optional Function | Over-torque protector/Dehumidify Heater/Passive contact switch | ||||
Remark | Any other input or output signal needed, please specified in purchase order. |