3 Phase High Frequency Online Rack Mount 60KVA Pure Sine Wave Ups Power Without Battery
The UPS adopts CyberPower's patented GreenPower UPS™ technology to enhance UPS operating efficiency, reduce heat generation, consume less power and save more energy costs than conventional UPS models.
The UPS provides Pure Sine Wave power output for sensitive equipment that requires smoother and cleaner input source. The Pure Sine Wave source ensures system is operating more efficiently to reduce power consumption and save electricity costs.
The UPS has built-in Automatic Voltage Regulation (AVR) function to regulate low voltages and over voltages when incoming utility power has fluctuations, thus providing consistent and reliable power to connected devices.
The LCD readout displays clear system information, such as power status, battery status, load status and more. It also features a user-friendly and intuitive interface, allowing users to easily manage and monitor the entire system.
The UPS outlets absorb surges and spikes caused by thunder and lightning, hence providing complete protection for equipment and devices.
MODEL | 30KL | 40KL | 60KL | |
CAPACITY* | 30KVA / 30KW | 40KVA / 40KW | 60KVA / 60KW | |
INPUT | ||||
Voltage Range | Low Line Loss | 110 VAC(Ph-N) ± 3 % at 50% Load; 176 VAC(Ph-N) ± 3 % at 100% Load | ||
Low Line Comeback | Low Line Loss Voltage + 10V | |||
High Line Loss | 300 VAC(L-N) ± 3 % at 50% Load; 276 VAC(L-N) ± 3 % at 100% Load | |||
High Line Comeback | High Line Loss Voltage - 10V | |||
Frequency Range | 46Hz ~ 54 Hz @ 50Hz system 56Hz ~ 64 Hz @ 60Hz system | |||
Phase | 3 Phase with Neutral | |||
Power Factor | ≧ 0.99 at 100% Load | |||
OUTPUT | ||||
Phase | 3 Phase with Neutral | |||
Output voltage | 360/380/400/415VAC (Ph-Ph) | |||
208*/220/230/240VAC (Ph-N) | ||||
AC Voltage Regulation | ± 1% | |||
Frequency Range (Synchronized Range) | 46Hz ~ 54 Hz @ 50Hz system; 56Hz ~ 64 Hz @ 60Hz system | |||
Frequency Range (Batt. Mode) | 50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz | |||
Transfer Time | Line Battery | 0 ms | ||
Inverter Bypass | 0 ms (When phase lock fails, <4ms interruption occurs from inverter to bypass) | |||
Inverter ECO | <10 ms | |||
BATTERY | ||||
Long-run Model | Type | Depending on applications | ||
Numbers | 32 ~ 40 (adjustable) | |||
Charging Current(max.) | 1.0~12.0A ±10% (Adjustable) | 1.0~16.0A ±10% (Adjustable) | 1.0~18.0A ±10% (Adjustable) | |
Charging Voltage | +/- 13.65 VDC * N ± 1% (N = 16~20) | |||
PHYSICAL | ||||
Long-run Model | Dimension, D X W X H mm | 797X438X176(4U) | ||
Net Weight (kgs) | 42 | 42 | 45 | |
MANAGEMENT | ||||
Smart RS-232 or USB | Supports Windows® 2000/2003/XP/Vista/2008/7/8/10, Linux, Unix, and MAC | |||
Optional SNMP | Power management from SNMP manager and web browser |