NYCZ500 Rod Type Magnetostrictive Level Gauge Liquid Water Level Sensor with High Accuracy
NYCZ500 Rod Type Magnetostrictive Level Gauge Working Principle
The product mainly consists of a measuring rod, an electronic chamber and a non-contact floating ball sleeved on the measuring rod. Magnetostrictive wire (waveguide wire) is installed in the measuring rod. The measuring rod is made of non-magnetic stainless steel tube, which protects the waveguide wire very well.
When the magnetostrictive liquid level meter is working, the pulse generator in the electronic chamber sends out a starting pulse. When this starting pulse is transmitted in the waveguide wire, it generates a rotating magnetic field moving in the direction of the waveguide wire. When this magnetic field meets the permanent magnetic field in the float ball, it generates a magnetostrictive stretching effect, causing the waveguide wire to twist and generate a constant speed mechanical wave. This mechanical wave propagates in two directions. The mechanical wave reaching the end of the measuring rod is absorbed by the damper. The mechanical wave transmitted back to the electronic chamber is sensed by the energy pickup mechanism installed in the electronic chamber and converted into the corresponding current pulse. The energy pickup mechanism calculates the time difference between the two pulses to accurately measure the height of the measured liquid level.
NYCZ500 Rod Type Magnetostrictive Level Gauge Design Features
1. Good safety: Magnetostrictive level meter has high explosion-proof performance, intrinsically safe, safe to use, especially suitable for the measurement of chemical materials and flammable liquids. No need to open the lid of the tank when measuring, avoiding the insecurity of manual measurement.
2. Magnetostrictive level meter is easy to install and simple to maintain: Magnetostrictive level meter is generally installed through the existing orifice at the top of the tank, especially suitable for the installation of underground storage tanks and tanks already in operation, and can not affect normal production during the installation process.
NYCZ500 Rod Type Magnetostrictive Level Gauge Technical Parameters
Model | NYCZ500 |
Typical application | Liquid level measurement, liquid-liquid interface measurement |
Antenna form | Rod type |
Antenna Material | 304, 316L (optional) |
Measuring range | 0~ 5m |
Measurement accuracy | ±0.5mm |
Measuring angle | 10° |
Power supply | 24VDC (2 wire, 4 wire), 220VAC |
Process temperature | -40~+200℃ |
Process pressure | -0.1~10.0MPa |
Process connection | Thread, flange, bracket (optional) |
Signal output | 4...20mA/HART/RS485/Modbus |
Working current | 4...20mA |
Load characteristic | Maximum load resistance 600Ω for current output; maximum load resistance 2mA for voltage output |
Response time | 0.2-5ms |
Protection level | IP65, IP67, IP68(optional) |
Explosion-proof grade | ExiaⅡCT6 Ga; ExiaⅡCT6 Gb |
Note: Products can be customized according to the specific requirements of users.
NYCZ500 Rod Type Magnetostrictive Level Gauge Related Pictures