Accurate Leak Detection Machine With Negative Pressure
Product size and material:
Test principle:
IPX8 test:
Positive pressure leak test:
Negative pressure leak test:
Product outline:
Compared with ordinary leak detection test devices, this air pressure visual leak detection tester has added negative pressure detection technology, which can detect small leaks in the sealing system in a short time. This is particularly important for situations where time is of the essence.
Standard features:
Item | Parameters |
Thickness of lid | 25mm |
Flange thickness | 30mm |
Tank thickness | 15mm |
Equipment net weight | Approx 120kg |
Pressure range | -50kPa ~ 300kPa |
Water depth range (positive pressure) | 1-30 meters |
Adjustment method | Automatic adjustment |
Pressure accuracy | 1 kPa |
Pressure error value | ±2kPa |
Set pressure of safety valve | 0.35Mpa(350kPa) |
Testing time9 | 0-999999S |
Power supply | 220V/50Hz |
Power | 100w |
Installation requirements:
The room needs to reserve a drain, and the bottom of the machine can be connected to a water pipe for drainage.
Remark:
1 The pictures in this document are for customer reference only, and there may be color differences between the actual model and the pictures.
2 This document only lists some test standards, which does not mean that other test requirements and standards cannot be conducted. Welcome to communicate and discuss with us.
3 One test only at the same time. The next project can be only carried out after the current test is completed. In addition, we can provide multi-functional customized test solutions according to user requirements.
4 The formula of the corresponding relationship between pressure and water depth: P=9.8d (Unit :kPa,m).
5 Sometimes there are gaps on the surface of the product's shell, but this part will not last for a long time or bubbles occasionally. Usually, the condition for us to judge whether it is leaking is: observe continuous bubbles.If the product is small and there is almost no space inside (such as lamp beads), the judgment standard is stricter:: that is, if there are air bubbles, it will be judged as leakage.
6 Negative pressure testing is suitable for testing samples whose internal pressure is higher than the external ambient pressure, or for quick testing (no inflation process).
7 It is necessary to avoid scratching the inner wall of the container by the sample, as scratches will affect the observation and video effects.
8 At present, only Chinese and English interfaces are supported; if other languages are introduced, the software can be updated remotely.
9 The time unit set by the factory is generally in seconds. If you want to extend the test time, you need to explain in advance.
10 The user needs to prepare an air compressor in advance (recommended gas storage capacity > 60L). If you need us to buy it on your behalf, you need to explain in advance.
11 The photos may not match the actual ones, and are for user reference only.
The detail image of product:
control panel
Tags: Leak Visualization Machine , Leak Inspection Machine with Visual Display , Leakage Detection Device