Specifications
Brand Name :
Newscen
Certification :
ISO9001, CE, TUV, SFDA
Place of Origin :
China
MOQ :
10 Boxes or 400 Kits (40 Kits/Box)
Price :
USD0.48/Cassette
Payment Terms :
T/T, Western Union, MoneyGram
Supply Ability :
100,000 Kits Per Day
Delivery Time :
8 days
Packaging Details :
40 Kits/Box, 50 Boxes/Carton, 317g/Box, 18kgs/Carton, Box Size: 250x125x65mm, Carton Size: 650x510x330mm
Specimen :
Serum, Plasma, Whole Blood
Methodology :
Colloidal Gold
Shelf Life :
2 Years
Format :
Cassette
OEM / ODM :
Available
Result Time :
Read in 20 Minutes
Description

HIV(1+2) Antibody Rapid Test Kit

For qualitative detection of HIV(1+2) antibodies in serum/plasma and whole blood

Main Features

1. Sensitivity: 100%

2. Specificity: Higher than 99%

3. Reliable: able to differentiate HIV Type I and Type II

4. Certified by Authoritative Certification

5. Unique 3-line Patented Design

6. Simple: No Instrument Required

7. Ambient Storage

3Min HIV Rapid Test Kit

Intended Use

Newscen HIV(1+2) Antibody Rapid Test is a single use, rapid immunoassay for qualitative detection of antibodies to Human Immunodeficiency Virus type 1 and 2 (HIV-1/2) in human serum, plasma or whole blood collected from vein or fingertip. It is intended for use in medical institutions by trained staff.

Reagents and Materials Provided

Each kit contains:

1.40 test cassettes(individually pouched)

2.Each pouch contains one cassette with one desiccant bag

3.One bottle of diluent buffer(5ml)

4.40 disposable plastic droppers

5.Instruction for use

Materials Required But Not Provided

1.Timer or stopwatch

2.Blood collection devices, for the testing of venous whole blood, serum or plasma

3.Biohazard disposal container

4.Disposable gloves

For finger stick samples, the following materials are required:

1. Alcohol pad

2. Sterile lancet

3. Sterile gauze or cotton

3Min HIV Rapid Test Kit

Storage

Newscen HIV(1+2) Antibody Rapid Test should be stored at room temperature (4-30℃, do not freeze) for 24 months from the date of manufacture.

Keep the test cassette in sealed pouch until use. Once you have taken the test cassette out of the pouch, perform the test as early as possible(within 1hour) to avoid test cassette from becoming moist. Do not use the test beyond the indicated expiration date.

The diluent buffer should be stored at room temperature(4-30℃, do not freeze) .

Warning

For Invitro Diagnostic Use ONLY

Read the package insert completely before use. It is very important that the correct procedure is followed. Fail to add the patient sample may lead to a false negative result (i.e.a missed positive)

3Min HIV Rapid Test Kit

Sample Collection and Test Preparation

Finger stick Specimens(Whole Blood)

1.Clean the area to be lanced with an alcohol pad.

2.Squeeze the end of the fingertip and pierce it with a sterile lancet.

3.Wipe away the first drop of blood with sterile gauze or cotton; collect the sample from the second drop.

4.Use dropper to obtain appropriate amount of fresh blood and dispense into the sample well.

Finger stick whole blood should be used immediately after collection.

Serum/Plasma specimens:fresh serum or plasma specimen can be used. No special patient preparation required.

Plasma

1.Collect whole blood into a collection tube(containing EDTA, Na-citrate or heparin) by venipuncture.

2.Separate the plasma by centrifugation.

Serum

1.Collect whole blood into a collection tube(containing no anticoagulants) by venipuncture.

2.Allow the blood to clot.

3.Separate the serum by centrifugation.

Any visible particulate matter in the specimen should be removed by centrifugation or filtration. Avoid using of hemolytic, turbid, microorganism contaminated specimens or specimens stored for over 5 days at 4°C.Specimen should be stored frozen at-20°C for maximum 3 months. Avoid specimen deterioration by multiple freeze-thaw cycles.

Venous Whole Bloods

Venous whole blood can be used immediately after collection or stored up to 4 days at 2-8°C.

3Min HIV Rapid Test Kit

Assay Procedure

1.Place the test cassette on flat surface. Before unseal the pouch, allow the test cassette to reach room temperature(4-30°C) .Use it immediately once unsealed.

2.Open the pouch and add1drop(30-40uL) of specimen into the sample well(S) .

3.When the specimen is completely absorbed, slowly add1drop(45-55pL) of diluent buffer vertically into the sample well(s) .

4.Avoid dropping specimen or diluent buffer in the observation window.

5.Do not allow the diluent buffer bottle touch the sample well when dropping the diluent buffer so as to prevent the cross contamination with the specimen.

6.Observe the result between 15-30 minutes after the diluent buffer added.

Built-In Control

Newscen HIV(1+2) Antibody Rapid Test has a built-in procedural control that demonstrates assay validity. A redline appeared on the control zone(C) indicates that the test runs correctly.

3Min HIV Rapid Test Kit

3Min HIV Rapid Test Kit

Send your message to this supplier
Send Now

3Min HIV Rapid Test Kit

Ask Latest Price
Brand Name :
Newscen
Certification :
ISO9001, CE, TUV, SFDA
Place of Origin :
China
MOQ :
10 Boxes or 400 Kits (40 Kits/Box)
Price :
USD0.48/Cassette
Payment Terms :
T/T, Western Union, MoneyGram
Contact Supplier
3Min HIV Rapid Test Kit
3Min HIV Rapid Test Kit
3Min HIV Rapid Test Kit
3Min HIV Rapid Test Kit

Newscen Biopharm Co., Limited

Active Member
5 Years
tianjin, tianjin
Since 2003
Business Type :
Manufacturer, Seller
Employee Number :
200~300
Certification Level :
Active Member
Contact Supplier