Specifications
Brand Name :
Newscen
Model Number :
Typhoid IgG/IgM
Certification :
ISO9001, CE, TUV, FDA
Place of Origin :
China
MOQ :
10 Boxes or 400 Kits (40 Kits/Box)
Price :
USD0.25/Cassette
Payment Terms :
T/T, Western Union, MoneyGram
Supply Ability :
100,000 Kits Per Day
Delivery Time :
8 days
Packaging Details :
40 Kits/Box, 50 Boxes/Carton, 317g/Box, 18kgs/Carton, Box Size: 250x125x65mm, Carton Size: 650x510x330mm
Usage :
For In Vitro Diagnostic Use Only
Methodology :
Colloidal Gold
Specimen :
Serum, Plasma, Whole Blood
Format :
Cassette
Box Color :
Orange
OEM/ODM :
Acceptable
Description

Typhoid IgG/IgM Rapid Test

For the qualitative detection of Typhoid IgG/IgM Antibody in serum/ plasma/whole blood

Typhoid IgG/IgM Combo Rapid Test Kit High Accurate Home Use Infectious Disease Typhoid Fever Fast Diagnostsic Cassette

Intended Use


The Typhoid IgG/IgM Rapid Test is a lateral flow immunoassay for the simultaneous detection and differentiation of anti-Salmonella typhi (S. typhi) IgG and IgM in human serum or plasma. It is intended to be used as a screening test and as an aid in the diagnosis of infection with S. typhi. Any reactive specimen with the Typhoid IgG/IgM Rapid Test must be confirmed with alternative testing method(s).

Home One Step In Vitro Diagnostic Typhoid IgG IgM Rapid Test

Principle


Typhoid fever is caused by S. typhi, a Gram-negative bacterium. World-wide an estimated 17 million cases and 600,000 associated deaths occur annually. Patients who are infected with HIV are at significantly increased risk of clinical infection with S. typhi. Evidence of H. pylori infection also presents an increase risk of acquiring typhoid fever. 1-5% of patients become chronic carrier harboring S. typhi in the gallbladder.


The clinical diagnosis of typhoid fever depends on the isolation of S. typhi from blood, bone marrow or a specific anatomic lesion. In the facilities that can not afford to perform this complicated and time-consuming procedure, Filix-Widal test is used to facilitate the diagnosis. However, many limitations lead to difficulties in the interpretation of the Widal test3,4.


In contrast, the Typhoid IgG/IgM Rapid Test is a simple and rapid laboratory test. The test simultaneously detects and differentiates the IgG and the IgM antibodies to S. typhi specific antigen5 thus to aid in the determination of current or previous exposure to the S. typhi.

Home One Step In Vitro Diagnostic Typhoid IgG IgM Rapid Test

Assay Procedure


1. Bring the specimen and test components to room temperature if refrigerated or frozen. Mix the specimen well prior to assay once thawed.


2. When ready to test, open the pouch at the notch and remove device. Place the test device on a clean, flat surface.


3. Fill the pipette dropper with the specimen. Holding the dropper vertically, dispense 1 drop (about 30-45 µL) of specimen into the sample well making sure that there are no air bubbles. Then add 1 drop (about 35-50 µL) of Sample Diluent immediately.


4. Results can be read in 15 minutes. Positive results can be visible in as short as 1 minute.

Home One Step In Vitro Diagnostic Typhoid IgG IgM Rapid Test

Interpretation of Result

Home One Step In Vitro Diagnostic Typhoid IgG IgM Rapid Test

Negative: If only the C band presents, the absence of any burgundy color in the both test bands (M and G) indicates that no anti-S. typhi antibody is detected in the specimen. The result is negative or non-reactive.


IgG Positive: In addition to the presence of C band, if only G band is developed, the test indicates for the presence of anti- S. typhi IgG in the specimen. The result is IgG positive or reactive.


IgM Positive: In addition to the presence of C band, if only M band is developed, the test indicates for the presence of anti- S. typhi IgM in the specimen. The result is IgM positive or reactive.


IgM and IgG Positive: In addition to the presence of C band, both M and G bands are developed, the test indicates for the presence of anti-S. typhi IgG and IgM in the specimen. The result is both IgG and IgM positive or reactive.


Invalid: The test results are INVALID, if no control line is visible, regardless of the presence or absence of lines in the IgG or IgM test zone of the strip. Repeat the test using a new cassette.

Home One Step In Vitro Diagnostic Typhoid IgG IgM Rapid Test

Home One Step In Vitro Diagnostic Typhoid IgG IgM Rapid Test

Home One Step In Vitro Diagnostic Typhoid IgG IgM Rapid Test

Send your message to this supplier
Send Now

Home One Step In Vitro Diagnostic Typhoid IgG IgM Rapid Test

Ask Latest Price
Brand Name :
Newscen
Model Number :
Typhoid IgG/IgM
Certification :
ISO9001, CE, TUV, FDA
Place of Origin :
China
MOQ :
10 Boxes or 400 Kits (40 Kits/Box)
Price :
USD0.25/Cassette
Contact Supplier
Home One Step In Vitro Diagnostic Typhoid IgG IgM Rapid Test
Home One Step In Vitro Diagnostic Typhoid IgG IgM Rapid Test
Home One Step In Vitro Diagnostic Typhoid IgG IgM Rapid Test
Home One Step In Vitro Diagnostic Typhoid IgG IgM Rapid Test

Newscen Biopharm Co., Limited

Active Member
5 Years
tianjin, tianjin
Since 2003
Business Type :
Manufacturer, Seller
Employee Number :
200~300
Certification Level :
Active Member
Contact Supplier
Submit Requirement