COVID-19 Saliva Collection Kit –Saliva with Funnel and Transport
Media manufactured in ISO certified facility
【FEATURES】
1. The kit includes 1 funnel and 2 collector tubes(3ml and 10ml both are available).
2. Use and application scope: Collection of human saliva specimen.
3. With medium or without the medium.
4. Excellent sealing design ensure leakproof.
5. Individual Packing or bulk packing
【PACKING】
30pc/box, 10box/CTN
Kit package: one collection funnel with tube+10ml tube+3ml medium +biohazard bag.
【INTENDED USE】
It is used to collect and store saliva samples from the mouth. The samples are
extracted for clinical in vitro diagnosis.
【MAIN COMPONMENTS】
Number | Composition | 30 Kits/box |
1 | Collection Funnel (with a collection tube) | 30 pcs/box |
2 | Saliva Preservation Tube(with 3ml saliva preservation solution ) | 30 pcs/box |
3 | Biohazard Bag | 30 pcs/box |
4 | Instructions | 1 pcs |
【How to Collect Your Own COVID-19 Saliva Specimen
(with Funnel and Transport Media)】
This step-by-step guide shows you how to collect your own saliva sample with a funnel and
transport media.
Duration: 3 min
Instructions
Do NOT eat, drink, chew gum, smoke, or vape for at least 30 minutes before collecting saliva.
Wash hands and make sure you have everything you need before you begin. A saliva test kit
consists of an empty tube with blue liquid in the cap, a funnel, a clear bag to place the sample,
a COVID-19 test requisition form, and a label for the tube with your information. Be sure to
leave the small absorbent paper in the provided biohazard bag.
Label the tube with the date of collection, full name and date of birth or Health Card Number.
Failure to provide this information may result in rejection or testing delay.
Complete all required fields of the COVID-19 test requisition form.
Peel back the paper on the test kit and remove the cap containing the blue liquid and the
specimen tube with attached funnel. Stick the completed label on the tube. Place the cap upside
down in a clean, secure spot, it will be used to seal the sample.
To promote saliva production, rub the inside of your cheek with your tongue and allow saliva to
pool in your mouth, then begin carefully spitting into the funnel allowing saliva to run into the
tube until it reached the fill line (not including bubbles).
Once you have collected enough saliva, twist off the funnel top and place in the garbage.
Immediately put the cap containing the blue liquid back on the tube, twisting tightly until you
hear a click and the blue liquid mixes into the tube.
Shake tube for five seconds to mix saliva and liquid and do not reopen the tube or remove any liquid.
Place the tube in the provided biohazard bag and place the fully completed test requisition form
into the outer pocket of the bag. Close the bag.
Wash your hands and check with your school for where to drop off the test. The specimen should
be kept at room temperature and dropped off within two hours of collection.
How to Collect a Saliva Sample for a COVID 19 PCR Test
This step-by-step guide shows you how to use a saliva test kit to collect a saliva specimen for
a COVID-19 test.
Duration: 3 min
Instructions
Before collecting saliva:
Please read all of these instructions before beginning
Drink a cup of water 60 minutes before collecting saliva to ensure adequate hydration for
saliva flow.
Do NOT eat, drink, chew gum, smoke, or vape for at least 30 minutes before collecting saliva
Wash hands with soap and water or hand sanitizer
For specimen collection center personnel:
While wearing appropriate personal protective equipment (PPE), open the sealed bag and
remove the specimen container and funnel from the package.
Label the specimen container with the patient’s full name, date of collection, and one other
unique identifier such as date of birth or Health Card Number. Failure to provide this information
may result in rejection or testing delay.
【STORAGE CONDITIONS】
Store at temperature 5 - 25 ℃.
【SAPMLE REQUIREMENTS】
Applicable sample types: Saliva.
Storage and transportation of samples: After the sample is collected, it should be transported to the corresponding laboratory for testing within 48 hours, and the storage temperature is 2-8℃. If it cannot be transported to the laboratory within 48 hours, it should be stored at -20 ℃ or below and sent to the corresponding laboratory within one week. The sample should avoid repeated freezing and thawing.
【INSTRUCTIONS】
1 | Clean your mouth 30 minutes before collecting the saliva sample, rotate the tongue in the mouth to enrich saliva. |
2 | Deliver saliva into the collection funnel, until the 2 mL line is as instructed on the tube. |
3 | Hold the saliva collection tube in an upright position, and use the other hand to unscrew the saliva preservation solution tube cap. |
4 | Keep the collection funnel upright, and pour the saliva preservation solution slowly into the collection tube. |
5 | Keep the collection tube upright, remove the collection funnel. |
6 | Screwcap onto the collection tube, and invert gently 5 times to mix the saliva and saliva preservation solution thoroughly. Finally, put it in a biohazard bag for easy transportation. |
12 months
【INDEX OF SYMBOL】
【EXPORTER】
Magnus International Limited
F12, New City International Mansion A, 234 Huapao Ave.
Liuyang, Hunan Province 410300 China
Contact: Goodwellmedical@gmail.com
【AUTHORIZED REPRESENTATIVE】
Lotus NL B.V.
Koningin Julianaplein 10, 1e Verd, 2595AA, The Hague, Netherlands.
【FACTORY VIEW】
【FACTORY WORKSHOP】
【PRODUCTION】
【PRODUCT AND STANDARDS】
【CERTIFICATIONS】
【FAQ】