Product Name | Adenovirus Antigen Rapid Test |
Formats | Strip(3mm)Device(4mm) uncut sheet |
Place of Origen | China |
Specimen | Urine |
Read Time | 15 minutes |
Shelf life | 2 years |
Package | uncut sheet |
Storage | 2℃-30℃ |
For professional in vitro diagnostic use only.
The Adenovirus Antigen Rapid Test Device is a rapid visual immunoassay for the qualitative presumptive detection of adenovirus in human fecal specimens. This kit is intended to be used as an aid in the diagnosis of adenovirus infection.
Table: Adenovirus Rapid Test vs. Other Rapid Test
Method | Other Rapid Test | Total Results | ||
Adenovirus Antigen Rapid Test |
Results | Positive | Negative | |
Positive | 82 | 1 | 83 | |
Negative | 0 | 156 | 156 | |
Total Results | 82 | 157 | 239 |
Relative Sensitivity:100% (95.6%-100%)
Relative Specificity: 99.4% (96.5%-99.9%)*
Overall Agreement:99.6% (97.7%-99.9%)*
*95% Confidence Interval
Specificity
Cross reactivity with following organisms has been studied at 1.0 x 107 organisms/ml. The following organisms were found negative when tested with the Adenovirus Antigen Rapid Test Device.
Staphylococcus aureus | Proteus mirabilis | Neisseria gonorrhea |
Pseudomonas aeruginosa | Acinetobacter spp | Group B Streptococcus |
Enterococcus faecalis | Salmonella choleraesius | Proteus vulgaris |
Group C Streptococcus | Gardnerella vaginalis | Enterococcus faecium |
Klebsiella pneumoniae | Acinetobacter calcoaceticus | Hemophilus influenzae |
Branhamella catarrhalis | E.coli | Neisseria meningitidis |
Candida albicans | Chlamydia trachomatis |
Rapid and accurate diagnosis of gastroenteritis due to adenovirus is helpful in establishing the etiology of gastroenteritis and related patient management. Other diagnostic techniques such as electron microscopy (EM) and nucleic acid hybridization are expensive and labor-intensive. With the self-limiting nature of adenovirus infection, such expensive and labor-intensive tests may not be necessary..