DC Fuse HKPV-30/32 series

Overview
The HKPV-30/32 series of photovoltaic fuses are mainly used in the solar photovoltaic power generation DC combiner box to break the line overload and short-circuit current generated by the current feedback of the solar panel photovoltaic modules and inverters that may generate solar energy thereby protecting For the use of solar photovoltaic panels,fuses can also be optionally used in any other DC circuit for line overload and short circuit protection of electrical components.


Use environment
The upper limit of ambient airtemperature does not exceed+90℃, and the lower limit ofair temperatureis notlowerthan-40°C;

The altitude of the installation site does not exceed 3000m;

At a maximum temperature of +40,the relative humidity ofthe air does not exceed 50% allowing higher humidity at lower temperatures,for example upto 90%at+25C.Special measures should be taken for condensation that occasionally occurs due to temperature changes;

In a medium free of explosion hazard, and where there is no sufficient aas or conductive dust to corrode the metaland destroytheinsulation; Pollution degree 3.

Terminals/connection

Type designation HKPV-32 HKPV-30
Type designation --- ---
Type of Terminal Pillarterminal Pillar terminal
Material/plating of the terminal Zinc plated Steel Zinc plated Steel
Material/plating of the washer Zinc plated Copper Zinc plated Copper
Material/plating of the screw Zinc plated Iron Zinc plated Iron
Type of conductor

Flexible:2.5mm2-6mm2,

Copper type;hard wire:2.5mm2-6mm

Connectable conductors

ISO(mm2) or AWG number

metric equivalent(mm²)

2.5mm2-6mm 2.5mm2-6mm
Number of conductors perterminal 1 1
Required preparation of the conductor Example: No prepared conductor
Max.Stripping length(mm) 8mm 8mm
Tightening torque(N·m) 2Nm,M5 2Nm,M5

Technical Parameters

Type designation HKPV-32V HKPV-30
Ambient temperature -5C-+40C -5C~+40C
Contact material Copper(T2Y) Copper(T2Y)
Contact form FormU Form U
Interrupting medium Air Air
-method of operation
-suitability for isolation suitable suitable
-degree of protection
-kind ofcurrent DC DC
inthe case of a.c,number of phases and
rated frequency
-breaking arrangement for fused devices Double Break Double Break
Rated and limiting values,main circuit / /
-rated operationalvoltage Ue(V) 1500V DC 1000VDC
-rated insulation voltage Ui(V): 1800V DC 1200VDC
-rated impulse withstand voltage Uimp(kV): 8kV 6kV
Rated operational voltage Ue 1500VDC 1000VDC
Rated operational current le 32A 30A
Insulation voltage 1800V 1200V
Conventional free air thermal current(Ith) 32A 30A
Conventional enclosed the rmalcurrent(lthe) 32A 30A
Utilization category DC-20A DC-20A
Rated short-time withstand current -- --
Rated short-circuit making current -- --
Conditional short-circuit current 25kA 20kA
Short circuit protective device

Tested withfuse-link:YRPV-32

(SOLAR,gPV,10x85,DC 1500V,

32A,Interrupting Capacity:25kA)

Tested with fuse-link:YRPV-30

(SOLAR,gPV,10x38,DC1000V,

30A,Interrupting Capacity:20kA)

IP code Ip20 Ip20
Pollution degree 3 3
Suitability for isolation - -
Send your message to this supplier
Send Now

1500VDC PV System Protection DC Solar Pv Fuses HKPV-30/32 Series

Ask Latest Price
Brand Name :
HAROK
Model Number :
HKPV-30/32 series
MOQ :
3000
Contact Supplier
1500VDC PV System Protection DC Solar Pv Fuses HKPV-30/32 Series
1500VDC PV System Protection DC Solar Pv Fuses HKPV-30/32 Series

Yueqing Vorax Electric CO.,LTD

Verified Supplier
3 Years
zhejiang
Since 2003
Business Type :
Manufacturer
Employee Number :
>100
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement