Specifications
Brand Name :
HAROK
Model Number :
VK007LE
Place of Origin :
CHINA
MOQ :
3000PCS
Payment Terms :
L/C, T/T
Poles number :
1P + N, 2P, 3P, 3P+N, 4P
Type :
Type AC, Type A
Rated voltage :
240V, 415V
Mechanical life :
2000
Standard :
IEC/EN 61009-1
Rated frequency :
50/60Hz
Description

VK007LE Residual Current Operated Circuit Breaker With Over-Current Protection RCBO 50/60HzRCBO | Residual Current Circuit Breaker

with Overcurrent Protection

VK007LE Residual Current Operated Circuit Breaker with Overcurrent Protection (RCBO)

1. General

VK007LE residual current operated circuit breakers with overcurrent protection (RCBO) are suitable for lines with AC 50/60Hz, rated voltage 240V/415V, rated current up to 63A and for purposes of residual current protection, overload and short circuit protection. When any personal electric shock occurs or the circuit leakage current exceeds the predetermined value, the residual current operated circuit breaker can automatically cut off the power supply in a very short period of time, so that the safety of persons and electrical equipment can be operated. The residual current operated circuit breaker can be used for infrequent conversion of lines under normal conditions, and applied under occasions such as industrial, and commercial, high-rise buildings and residential houses.

2. Technical parameters

2.1 The tripping characteristic curves are as shown below. VK007LE Residual Current Operated Circuit Breaker With Over-Current Protection RCBO 50/60Hz

2.2 Basic parameters

Standard IEC/EN 61009-1
Main Specifications Model No. VK007LE
Rated current In 6A, 10A, 13A,16A, 20A, 25A, 32A, 40A, 50A, 63A
Tripping Curve B: (3 ~ 5) In, C: (5 ~ 10) In
Poles 1P + N, 2P, 3P, 3P+N, 4P
Type (wave form of the earth leakage sensed) Type AC, Type A
Mechanical features Rated voltage Ue AC240V, AC415V
Frame size rated current In 63A
Rated residual operating current I△n 30mA, 100mA, 300mA, 500mA
Rated residual non-operating current I△no 15mA, 50mA, 150mA, 250mA
Rated short-circuit breaking capacity Icn 4500A, 6000A

Rated residual making and

breaking capacity I△m

500A
Electrical life 2,000
Mechanical life 2,000
Rated impulse withstand voltage Uimp 4000V
Connection From top and bottom

2.3 The residual current breaking times

In (A) I△n (A) Breaking time when the residual current assumes the following values (s)
I△n 2I△n 5I△n 5A, 10A, 20A, 50A, 100A, 200A, 500A(a) I△t(b)
6~63 0.01, 0.03, 0.1, 0.3, 0.5 0.1 0.05 0.04 0.04 0.04

a. For tests of 5A, 10A, 20A, 50A, 100A, 200A and 500A, the current values beyond the lower limit of over-current instantaneous tripping are not tested.

B. Tests are done when I△t is equal to the lower limit current of over-current instantaneous tripping of type B and type C.

2.4 The over-current protection characteristics

No. Rated current In (A) Initial state Test current (A) Specified time (t) Expected result Remarks
a 6 ~ 63 Cold state 1.13 In t ≥ 1h Non-tripping
b Immediately after sequence a 1.45 In t < 1h Tripping Increase to the specified current within 5s after test item a.
c Cold state 2.55 In 1s < t < 60s Tripping
d Cold state 3 In t ≥ 0.1s Non-tripping Curve B
5 In t < 0.1s Tripping
5 In t ≥ 0.1s Non-tripping Curve C
10 In t < 0.1s Tripping

Product Description:

RCBO Type A is a Residual Current Operated Circuit Breaker with over-current protection. It is equipped with a reliable, long-lasting, and strong mechanical life of 2000. It has two connection options, from top to bottom and from bottom to top. The rated residual current operating time is 0.1 seconds or less. It is also equipped with four types of rated residual non-operating current, 0.005A, 0.015A, 0.05A, and 0.15A. Its rated voltage is AC240V. It is a reliable and effective RCBO Circuit Breaker and provides a safe and secure environment.

Features:

  • Product Name: RCBO Type A
  • Rated voltage Ue: AC240V
  • Frame size rated current Inm: 50A
  • Rated Breaking Capacity: 6kA
  • Rated Current: 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A
  • Classified by Type of Instantaneous Tripping: Type B: (3 ~ 5) In, Type C: (5 ~ 10) In

Applications:

RCBO Type A, a Residual Current Operated Circuit Breaker with over-current protection, is a reliable and secure electrical protection device. Developed by HAROK, RCBO Type A features a wide range of models, including VRL22, VAL003, VKL003, VDL006, VRL11, VRL01, VRL02, VRL03 and VK007LE, and is manufactured in CHINA. It provides a Rated Residual Current Operating Time of ≤0.1s, and is classified by Type of Instantaneous Tripping as Type B: (3 ~ 5) In, and Type C: (5 ~ 10) In. The Rated Frequency is 50/60Hz, and the Rated Residual Operating Current is 0.01A, 0.03A, 0.1A and 0.3A. The Rated Residual Current On-state is ≤0.2mA. RCBO Type A is an ideal choice for ensuring safety and stability in your electrical systems.

Technical Parameters:

Property Value
Rated Current 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A
Rated Residual Current Off-state ≤0.1mA
Rated residual operating current I△n 0.01A, 0.03A, 0.1A, 0.3A
Rated Breaking Capacity 6kA
Rated voltage Ue AC240V
Rated impulse withstand voltage Uimp 6000V
Rated Frequency 50/60Hz
Electrical life 2000
Rated short-circuit breaking capacity Icn 230/240V 6000A, 10000A; 120V 15000A
Rated Residual Current Operating Time ≤0.1s

Customization:

RCBO Type A - Circuit Breaker HAROK
Product Overview
  • Brand Name: HAROK
  • Model Numbers: VRL22, VAL003, VKL003, VDL006, VRL11, VRL01, VRL02, VRL03, VK007LE
  • Place of Origin: CHINA
  • Electrical life: 2000
  • Rated Current: 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A
  • Rated Residual Current On-state: ≤0.2mA
  • Rated Voltage Ue: AC240V
  • Classified by Type of Instantaneous Tripping: Type B: (3 ~ 5) In, Type C: (5 ~ 10) In
Features and Benefits

RCBO Type A is a circuit breaker designed to protect electrical systems from overload, short circuits and ground faults. It is suitable for both residential and commercial applications. The product features a high-quality design that ensures its durability and reliable performance. With its rated current of 6A, 10A, 16A, 20A, 25A, 32A, 40A, and 50A, it is suitable for a wide range of applications. It also offers a rated residual current on-state of ≤0.2mA and is classified by type of instantaneous tripping into Type B: (3 ~ 5) In and Type C: (5 ~ 10) In.

Why Choose HAROK RCBO Type A?

HAROK RCBO Type A is a reliable circuit breaker with a long electrical life of 2000 that is designed to provide protection against overloads, short circuits and ground faults. With its wide range of rated current and rated voltage, it is suitable for a range of applications. It is also highly reliable and durable, making it an ideal choice for any commercial or residential application.

Packing and Shipping:

Packaging and Shipping of RCBO Type A

To ensure the safe and secure delivery of RCBO Type A, we use the following packaging and shipping methods:

  • The product is securely packaged in a box, using durable corrugated cardboard.
  • The box is then sealed with reinforced tape.
  • The product is then shipped via ground delivery service.

Send your message to this supplier
Send Now

VK007LE Residual Current Operated Circuit Breaker With Over-Current Protection RCBO 50/60Hz

Ask Latest Price
Brand Name :
HAROK
Model Number :
VK007LE
Place of Origin :
CHINA
MOQ :
3000PCS
Payment Terms :
L/C, T/T
Poles number :
1P + N, 2P, 3P, 3P+N, 4P
Contact Supplier
VK007LE Residual Current Operated Circuit Breaker With Over-Current Protection RCBO 50/60Hz
VK007LE Residual Current Operated Circuit Breaker With Over-Current Protection RCBO 50/60Hz

Yueqing Vorax Electric CO.,LTD

Verified Supplier
3 Years
zhejiang
Since 2003
Business Type :
Manufacturer
Employee Number :
>100
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement