Specifications
Brand Name :
HAROK
Model Number :
VAL003
Place of Origin :
CHINA
MOQ :
3000PCS
Payment Terms :
L/C, T/T
Rated current :
6mA, 10mA, 30mA, 100mA, 300mA 3mA, 5mA, 15mA, 50mA, 150mA
Rated voltage :
240V, 120V
Mechanical life :
2000
Breaking capacity :
240V: 4500A, 6000A, 10000A 120V: 15000A
Pole :
Type B: (3 ~ 5) In, Type C: (5 ~ 10) In
Tripping curve :
Type B: (3 ~ 5) In, Type C: (5 ~ 10) In
Description


VAL003 Residual Current Operated Circuit Breaker with over-current protection(RCBO)

(MCB sized 1 module with switched neutral)

1. General

VAL003 residual current operated circuit breakers are suitable for lines with AC 50/60Hz, rated voltage 240V, 120V, rated current up to 40A and for purposes of residual current protection, overload and short circuit protection. When any personal electric shock occurs or the circuit leakage current exceeds the predetermined value, the residual current operated circuit breaker can automatically cut off the power supply in a very short period of time, so that the safety of persons and electrical equipment can be operated. The residual current operated circuit breaker can be used for infrequent conversion of lines under normal conditions, and applied under occasions such as industrial, and commercial, high-rise buildings and residential houses.

2. Technical parameters

2.1 The tripping characteristic curves are as shown below.

VAL003 Type B Residual Current Operated Circuit Breaker With Over-Current Protection With Rated Voltage AC240V, AC120V

2.2 Basic parameters

Standard IEC/EN 61009-1
Main Specifications Model No. VAL003
Rated current In 5A, 6A, 10A, 13A, 15A, 16A, 20A, 25A, 30A, 32A, 35A, 40A
Classified by Type of Instantaneous Tripping Type B: (3 ~ 5) In, Type C: (5 ~ 10) In
Poles 1P + N
Type (wave form of the earth leakage sensed) Type B
Mechanical features Rated voltage Ue AC240V, AC120V
Frame size rated current In 40A
Rated residual operating current I△n 6mA, 10mA, 30mA, 100mA, 300mA
Rated residual non-operating current I△no 3mA, 5mA, 15mA, 50mA, 150mA
Rated short-circuit breaking capacity Icn 240V: 4500A, 6000A, 10000A 120V: 15000A

Rated residual making and

breaking capacity I△m

500A
Electrical life 2,000
Mechanical life 2,000
Rated impulse withstand voltage Uimp 4000V
Connection From top and bottom, from bottom and top

2.3 The residual current breaking times

In (A) I△n (A) Breaking time when the residual current assumes the following values (s)
I△n 2I△n 5I△n 5A, 10A, 20A, 50A, 100A, 200A, 500A(a) I△t(b)
6~40 0.01, 0.03, 0.1, 0.3 0.1 0.05 0.04 0.04 0.04

a. For tests of 5A, 10A, 20A, 50A, 100A, 200A and 500A, the current values beyond the lower limit of over-current instantaneous tripping are not tested.

B. Tests are done when I△t is equal to the lower limit current of over-current instantaneous tripping of type B and type C.

2.4 The over-current protection characteristics

No. Rated current In (A) Initial state Test current (A) Specified time (t) Expected result Remarks
a 6 ~ 40 Cold state 1.13 In t ≥ 1h Non-tripping
b Immediately after sequence a 1.45 In t < 1h Tripping Increase to the specified current within 5s after test item a.
c Cold state 2.55 In 1s < t < 60s Tripping
d Cold state 3 In t ≥ 0.1s Non-tripping Type B
5 In t < 0.1s Tripping
5 In t ≥ 0.1s Non-tripping Type C
10 In t < 0.1s Tripping

3. Outline and installation dimensions (mm)

VAL003 Type B Residual Current Operated Circuit Breaker With Over-Current Protection With Rated Voltage AC240V, AC120VVAL003 Type B Residual Current Operated Circuit Breaker With Over-Current Protection With Rated Voltage AC240V, AC120V

Product Description:

RCBO Type B – A Residual Current Circuit Breaker with Overcurrent Protection

RCBO Type B is a residual current circuit breaker with overcurrent protection, designed to provide reliable protection against electric shock and fire hazards. It is classified by type of instantaneous tripping, with Type B (3~5) In and Type C (5~10) In. It has a rated voltage of AC240V and rated impulse withstand voltage Uimp of 6000V. Additionally, it offers a range of rated residual non-operating current from 0.005A to 0.15A.

This RCBO Type B is a great choice for any residential or commercial application, providing reliable protection from electrical hazards. It is an effective solution for protecting against electric shock and fire hazards, and for ensuring the safety of users.

The RCBO Type B is an ideal choice for safety, providing reliable protection from electrical hazards. It is a great solution for residential and commercial applications, offering a wide range of rated residual non-operating current, a rated voltage of AC240V, and a rated impulse withstand voltage Uimp of 6000V. It is classified by type of instantaneous tripping, with Type B (3~5) In and Type C (5~10) In.

Choose the RCBO Type B for reliable protection from electrical hazards, and to ensure the safety of users in any residential or commercial application. With its wide range of rated residual non-operating current, rated voltage of AC240V, and rated impulse withstand voltage Uimp of 6000V, it is the perfect choice for any safety-conscious user.

Features:

  • Product Name: RCBO Type B
  • Rated impulse withstand voltage Uimp: 6000V
  • Rated Residual Non-Operating Current: 0.005A, 0.015A, 0.05A, 0.15A
  • Connection: From Top And Bottom, From Bottom And Top
  • Type: Type B

Applications:

HAROK RCBO Type B is a circuit breaker device that combines the functions of both a Residual Current Operated Circuit Breaker (RCBO) and a Type B circuit breaker. It is designed to protect electrical systems from dangerous overloads, short circuits, and earth leakage currents. It has a high electrical life rating of 2000 operations and is available in a variety of models, such as VRL22 2P, 4P, VRL11, VAL003, VKL003, VDL006, VRL01, VRL02, VRL03, and VK007LE 1P-4P. These models feature a rated residual operating current of 0.01A, 0.03A, 0.1A, and 0.3A. Additionally, HAROK RCBO Type B features a connection of either from top and bottom or from bottom and top. This RCBO is designed to be used in a wide variety of residential, commercial, and industrial settings, and its advanced protection features make it a safe and reliable choice for any environment.

Technical Parameters:

Product Name RCBO Type B
Type Type B
Poles 1P+N
Connection From Top And Bottom, From Bottom And Top
Rated Voltage AC240V
Rated Current 6A 10A 16A 20A 25A 32A 40A 50A
Rated Residual Making and Breaking Capacity I△m 500A
Rated Residual Non-Operating Current 0.005A, 0.015A, 0.05A, 0.15A
Rated Impulse Withstand Voltage Uimp 6000V
Electrical Life 2000

Customization:

HAROK Type B RCBO Circuit Breaker

Brand Name: HAROK

Model Number: VRL22 2P,4P VRL11 VAL003 VKL003 VDL006 VRL01 VRL02 VRL03 VK007LE 1P-4P

Place of Origin: CHINA

Rated residual making and breaking capacity I△m: 500A

Frame size rated current Inm: 50A

Classified by Type of Instantaneous Tripping: Type B: (3 ~ 5) In, Type C: (5 ~ 10) In

Rated Residual Operating Current: 0.01A, 0.03A, 0.1A, 0.3A

Rated Voltage: AC240V

HAROK Type B Residual Current Operated Circuit Breaker is specifically designed for protecting people from electric shock hazard. It has a rated residual making and breaking capacity of 500A, frame size rated current Inm of 50A, and rated voltage of AC240V. The circuit breaker is classified into Type B (3 ~ 5) In and Type C (5 ~ 10) In according to the type of instantaneous tripping, and the rated residual operating current can be 0.01A, 0.03A, 0.1A, 0.3A.

Support and Services:

RCBO Type B Technical Support and Service

At RCBO, we are dedicated to providing our customers with the highest quality technical support and service. Our experienced team of professionals are here to help you every step of the way, from initial product selection to installation and maintenance.

Our knowledgeable customer service representatives are available to answer any questions you have about our products. We also offer free technical support via phone, email, and our online Help Center. We strive to provide prompt responses and helpful solutions to all inquiries.

We also offer product installation and maintenance services for RCBO Type B. Our technicians are highly experienced and certified to work with our products. We offer comprehensive installation services, as well as regular maintenance, to ensure your product is running smoothly.

If you have any questions or need technical support or service for your RCBO Type B product, please contact us. We look forward to helping you get the most out of your product.

Packing and Shipping:

The RCBO Type B product is packaged and shipped in a cardboard box, with the following dimensions:

  • Length: 10 cm
  • Width: 8 cm
  • Height: 6 cm

The box should be labeled with the product name, description, weight, and handling instructions. The product should be wrapped with tissue paper to prevent any damage during transport. The box should also be sealed with tape, to ensure that the contents remain secure during transit.

FAQ:

Q1: What is the brand name of RCBO Type B?
A1: The brand name of RCBO Type B is HAROK.
Q2: What are the model numbers of RCBO Type B?
A2: The model numbers of RCBO Type B are VRL22 2P,4P VRL11 VAL003 VKL003 VDL006 VRL01 VRL02 VRL03 VK007LE 1P-4P.
Q3: Where is RCBO Type B manufactured?
A3: RCBO Type B is manufactured in China.
Q4: What features does RCBO Type B have?
A4: RCBO Type B has the features of over-current protection, short-circuit protection, leakage protection, and overload protection.
Q5: What are the applications of RCBO Type B?
A5: RCBO Type B is suitable for lighting, air conditioning, motors and other electrical equipment.

Send your message to this supplier
Send Now

VAL003 Type B Residual Current Operated Circuit Breaker With Over-Current Protection With Rated Voltage AC240V, AC120V

Ask Latest Price
Brand Name :
HAROK
Model Number :
VAL003
Place of Origin :
CHINA
MOQ :
3000PCS
Payment Terms :
L/C, T/T
Rated current :
6mA, 10mA, 30mA, 100mA, 300mA 3mA, 5mA, 15mA, 50mA, 150mA
Contact Supplier
VAL003 Type B Residual Current Operated Circuit Breaker With Over-Current Protection With Rated Voltage AC240V, AC120V
VAL003 Type B Residual Current Operated Circuit Breaker With Over-Current Protection With Rated Voltage AC240V, AC120V
VAL003 Type B Residual Current Operated Circuit Breaker With Over-Current Protection With Rated Voltage AC240V, AC120V
VAL003 Type B Residual Current Operated Circuit Breaker With Over-Current Protection With Rated Voltage AC240V, AC120V

Yueqing Vorax Electric CO.,LTD

Verified Supplier
3 Years
zhejiang
Since 2003
Business Type :
Manufacturer
Employee Number :
>100
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement