Specifications
Brand Name :
HAROK
Model Number :
VKL11
Place of Origin :
CHINA
Certification :
CE, CB, NF, ISI, SEMKO
MOQ :
5000
Packaging Details :
PAPER CARTON
Delivery Time :
4-6 weeks after payment
Payment Terms :
FOB NINGBO or SHANGHAI
Supply Ability :
100,000 PCS PER MONTH
Rated current In :
16A, 25A, 32A, 40A, 63A, 80A, 100A
Protection Degree :
IP20
Rated Voltage :
2P: 230/240V AC; 4P: 400/415V AC
Rated Impulse Withstand Voltage :
4kV
Rated conditional short-circuit current Inc :
10kA
Rated Residual Operating Current :
30mA
Operating Temperature :
-25℃~+55℃
Rated residual operating current I△n :
30mA, 100mA, 300mA, 500mA
Description

Super immunised RCD Type B

  • General

1.1 Function

VKL11B RCD and VKL11B+ RCD is appearance design, compact structure, good reliability, and high safety. They are universal residual current circuit breaker.

Residual current circuit breaker type B are suitable for domestic as well as industrial applications, where are used frequency inverters, PV plant, EV chargers and similar elements. B type provides a sensitivity to residual AC, pulsating and smooth DC current, together with high frequencies up to 1 kHz.

Residual current circuit breaker type B+ meet full type B feature , with additional tripping values are defined up to 20KHZ and they are below 420mA.

They are based on electronic technology, which brings advantages of more accurate measuring of residual current and, as a consequence, reduction of unwanted tripping. These devices also do not suffer with magnetization of the tripping unit.

1.2 Selection

Detectable wave form

Type B

Tripping is ensured for sinusoidal AC residual currents pulsed DC residual currents, alternating residual sinusoidal currents up to 1000Hz, pulsating direct residual currents and for smooth direct residual currents, whether applied suddenly or increasing slowly.

Type B+

Meet full type B feature , with additional tripping values are defined up to 20KHZ and they are below 420mA

Tripping sensitivity

30mA - additional protection against direct contact.

100mA - co-ordinated with the earth system according to the formula IΔn<50/R, to provide

protection against indirect contacts;

300mA - protection against indirect contacts, as well as fire hazard.

Tripping time

Instantaneous It ensures instantaneous tripping(without time-delay).

Short time delay

Selective (time delay)

1.3 Approvals and certificates

  • Technical parameters
Type B B+
Electrical
Design according to IEC/EN 62423, IEC/EN 61008-1, OVE E8601
VDE 0664-400
Current test marks as printed onto the device
Rated voltage Un

2P: 230/240V AC

4P: 400/415V AC

Rated frequency fn 50/60Hz
Mode of operation

"A type functionality: voltage independent

B and B+ type functionality: voltage dependent"

Operation voltage electronic 50 – 264V AC
Voltage range test circuit

2P: 184 – 264V AC

4P: 184 – 440V AC

Rated current In 40A

Rated residual

operating

current I△n

Instantaneous 30mA, 100mA, 300mA, 500mA 30mA, 100mA, 300mA
K-short time delayed (G, ASi) 30mA, 100mA, 300mA, 500mA 30mA, 100mA, 300mA
S- selective 100mA, 300mA, 500mA 100mA, 300mA
Sensitivity Alternating, pulsed and smooth direct currents
High frequency up to 1 kHZ High frequency up to 20kHZ
Rated insulation voltage Ui 500 V
Rated impulse withstand voltage Uimp 4 kV (1.2/50μs)
Rated conditional short-circuit current Inc 10 kA
Rated making and breaking capacity Im 1500 A
Peak withstand current

3 kA (8/20 μs) surge current proof

5 kA (8/20 μs) surge current proof for type S

Electrical isolation > 4 mm contact space

Maximum back-up fuse

In = 16-100A

Short circuit and overload protection

100 A gG/gL

Endurance

(operating cycles)

electrical components ≥ 2000
mechanical components ≥ 4000
Mechanical
Degree of protection IP20
Upper and lower terminals open mounted / lift terminals
Terminal capacity 1 - 25 mm2
Terminal torque 2 - 2.5 Nm
Busbar thickness 0.8 - 2 mm
Operating temperature -25°C ... +55°C
Storage- and transport temperature -40°C ... +70°C
Resistance to climatic conditions IEC/EN 61008
Contact position indicator mechanical red / green
Supply possibility top or bottom
Mounting position any

  • Special features regarding the use of SIQUENCE universal current-sensitive residual current device (Type B and Type B+)
    • Applications

3.1 Typical applications that are vulnerable to smooth DC residual currents:

- Frequency converters with a three-phase connection

- Medical equipment such as X-ray equipment or CT machines

- Photovoltaic or UPS systems

- Connection points (wall boxes, charging stations) for electric vehicles

- Elevator controllers

- Pipeline trace heating

- Test setups in laboratories

- Construction sites in accordance with BGI 608 information leaflet (Electronic equipment

on construction sites)

- Charging stations for battery-powered forklift trucks

- Cranes of all kinds

- Mixing plants if relevant loads are connected

- Variable-speed machine tools, such as milling and grinding machines or lathes

  • Wiring diagrams

Super Immunised RCD Type BSuper Immunised RCD Type B

  • Tripping characteristics

.B type

Super Immunised RCD Type B

  • Dimensions (mm)
  • Super Immunised RCD Type BSuper Immunised RCD Type B

Product Description:

RCD TYPE B is a Super immunised Residual Current Device that has been rated to provide superior protection. It is designed with a Rated Residual Operating Current of 30mA, 100mA, 300mA and 500mA, and a Rated Voltage of 2P: 230/240V AC and 4P: 400/415V AC. The Rated Residual Operating Time for RCD TYPE B is 0.03s, and it has a Rated Current of 16A, 25A, 32A, 40A, 63A, 80A and 100A.

This product is designed to provide superior protection for electrical circuits and equipment, and it is essential for the reliable operation of the electrical system in any residential, commercial or industrial environment. It is a reliable and cost-effective solution that can help reduce the risk of fire and electrical shock, and it is highly recommended for use in any environment.

Features:

  • Product Name: RCD TYPE B
  • High immunity RCD, RESIDUAL CURRENT DEVICE, Super immunised Residual Current Device
  • Rated Residual Operating Time: 0.03s
  • Rated Voltage: 2P: 230/240V AC; 4P: 400/415V AC
  • Rated residual operating current I△n: 30mA, 100mA, 300mA, 500mA
  • Rated Current: 30mA
  • Operating Temperature: -25℃~+55℃

Applications:

HAROK's RCD TYPE B (Residual Current Device) with model number VKL11 is a reliable and stable product, certified with CE, CB, NF, ISI, and SEMKO standards. It has a minimum order quantity of 5000 and comes in a paper carton packaging. The delivery time is 4-6 weeks after payment, and the payment terms are FOB NINGBO or SHANGHAI. The supply ability is 100,000 PCS PER MONTH. The rated conditional short-circuit current inc is 10kA and the rated voltage is 2P: 230/240V AC; 4P: 400/415V AC. The rated residual operating current I△n is 30mA, 100mA, 300mA, 500mA, and the rated insulation voltage is 500V.

Technical Parameters:

Parameter Value
Product Name High immunity RCD, Super immunised Residual Current Device, TYPE B
Rated Voltage 2P: 230/240V AC; 4P: 400/415V AC
Rated Current 30mA
Rated Residual Operating Current 30mA
Rated Residual Operating Time 0.03s
Rated Residual Non-Operating Time 0.3s
Protection Degree IP20
Rated current In 16A, 25A, 32A, 40A, 63A, 80A, 100A
Rated conditional short-circuit current Inc 10kA
Rated Impulse Withstand Voltage 4kV

Support and Services:

Technical Support and Service for RCD TYPE B:

  • 24/7 technical support
  • Access to technical documentation library
  • Software upgrades
  • Hardware repair and maintenance services
  • Remote diagnostic and troubleshooting services
  • On-site technical assistance

Packing and Shipping:

The RCD TYPE B should be securely packaged, labeled, and shipped in accordance with applicable regulations and standards. The packaging should include the following:

  • Instructions for installation, operation, and maintenance
  • Product warranty information
  • Appropriate labels for hazard warning and handling
  • Corrosion protection such as VCI (vapor corrosion inhibitors) or other methods as required
  • Shock and vibration protection
  • Moisture protection
  • Appropriate outer packaging, such as cardboard boxes or crates, depending on the size of the shipment
Send your message to this supplier
Send Now

Super Immunised RCD Type B

Ask Latest Price
Brand Name :
HAROK
Model Number :
VKL11
Place of Origin :
CHINA
Certification :
CE, CB, NF, ISI, SEMKO
MOQ :
5000
Packaging Details :
PAPER CARTON
Contact Supplier
Super Immunised RCD Type B
Super Immunised RCD Type B
Super Immunised RCD Type B

Yueqing Vorax Electric CO.,LTD

Verified Supplier
3 Years
zhejiang
Since 2003
Business Type :
Manufacturer
Employee Number :
>100
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement