Specifications
Brand Name :
HAROK
Model Number :
VRL01
Place of Origin :
CHINA
MOQ :
3000PCS
Payment Terms :
L/C, T/T
Poles number :
1P+N
Rated voltage :
AC240V
Mechanical life :
2000
Standard :
IEC/EN 61009-1
Rated frequency :
50/60Hz
Rated Current :
6A, 10A, 16A, 20A, 25A, 32A, 40A, ,45A, 50A
Electrical life :
2000
CURVE :
TYPE B
Description

VRL01 MINI RCBO Type B With 0.15A Rated Residual Non-Operating Current With Standard IEC/EN 61009-1, AS/NZS 61009.1mini RCBO | Residual Current Operated Circuit Breaker with over-current protection

VRL01 Mini RCBO

(MCB sized 1 module with switched neutral)

1. General

1.1 Function

VRL01B RCBO type B and VRL01B+ RCBO type B+ are appearance design, compact structure, good reliability, and high safety. They are universal residual current circuit breaker with Overcurrent protection(RCBO).

Rated current up to 63A and for purposes of residual current protection, overcurrent (overload) and short circuit protection. When any personal electric shock occurs or the circuit leakage current exceeds the predetermined value, the RCBO can automatically cut off the power supply in a very short period of time, so that the safety of persons and electrical equipment can be operated.

Residual current circuit breaker with Overcurrent protection(RCBO) type B are suitable for domestic as well as industrial applications, where are used frequency inverters, PV plant, EV chargers and similar elements. B type provides a sensitivity to residual AC, pulsating and smooth DC current, together with high frequencies up to 1 kHz.

Residual current circuit breaker with Overcurrent protection(RCBO) type B+ meet full type B feature , with additional tripping values are defined up to 20KHZ and they are below 420mA.

They are based on electronic technology, which brings advantages of more accurate measuring of residual current and, as a consequence, reduction of unwanted tripping. These devices also do not suffer with magnetization of the tripping unit.

2. Technical parameters

2.1 The tripping characteristic curves are as shown below.

VRL01 MINI RCBO Type B With 0.15A Rated Residual Non-Operating Current With Standard IEC/EN 61009-1, AS/NZS 61009.1

2.2 Basic parameters

Standard IEC/EN 61009-1, AS/NZS 61009.1
Main Specifications Model No. VRL01
Rated current In 6A, 10A, 16A, 20A, 25A, 32A, 40A, ,45A, 50A
Classified by Type of Instantaneous Tripping Type B: (3 ~ 5) In, Type C: (5 ~ 10) In
Poles 1P + N
Type (wave form of the earth leakage sensed) Type B
;Mechanical features Rated voltage Ue AC240V
Frame size rated current Inm 50A
Rated residual operating current I△n 0.01A, 0.03A, 0.1A, 0.3A
Rated residual non-operating current I△no 0.005A, 0.015A, 0.05A, 0.15A
Rated short-circuit breaking capacity Icn 230/240V 6000A, 10000A; 120V 15000A

Rated residual making and

breaking capacity I△m

500A
Electrical life 2,000
Mechanical life 2,000
Rated impulse withstand voltage Uimp 6000V
Connection From top and bottom, from bottom and top

2.3 The residual current breaking times

In (A) I△n (A) Breaking time when the residual current assumes the following values (s)
I△n 2I△n 5I△n 5A, 10A, 20A, 50A, 100A, 200A, 500A(a) I△t(b)
5~40 0.006, 0.01, 0.03, 0.1, 0.3 0.1 0.05 0.04 0.04 0.04

a. For tests of 5A, 10A, 20A, 50A, 100A, 200A and 500A, the current values beyond the lower limit of over-current instantaneous tripping are not tested.

B. Tests are done when I△t is equal to the lower limit current of over-current instantaneous tripping of type B and type C.

2.4 The over-current protection characteristics

No. Rated current In (A) Initial state Test current (A) Specified time (t) Expected result Remarks
a 6 ~ 40 Cold state 1.13 In t ≥ 1h Non-tripping
b Immediately after sequence a 1.45 In t < 1h Tripping Increase to the specified current within 5s after test item a.
c Cold state 2.55 In 1s < t < 60s Tripping
d Cold state 3 In t ≥ 0.1s Non-tripping Type B
5 In t < 0.1s Tripping
5 In t ≥ 0.1s Non-tripping Type C
10 In t < 0.1s Tripping

3. Outline and installation dimensions (mm)

VRL01 MINI RCBO Type B With 0.15A Rated Residual Non-Operating Current With Standard IEC/EN 61009-1, AS/NZS 61009.1

Product Description:

RCBO Type B is a Residual Current Operated Circuit Breaker (RCBO) developed and manufactured in accordance with IEC/EN 61009-1 and AS/NZS 61009.1 standards. Its classified by Type of Instantaneous Tripping, Type B: (3 ~ 5) In, and Type C: (5 ~ 10) In, with frame size rated current Inm up to 50A. It has an adjustable rated residual operating current range of 0.01A, 0.03A, 0.1A, 0.3A and a rated residual making and breaking capacity I△m of 500A. It is designed for residential, industrial and commercial applications, and is suitable for protecting against electric fires, electric shocks and short-circuits.

Features:

  • Product Name: RCBO Type B
  • Connection: From Top And Bottom, From Bottom And Top
  • Type: Type B
  • Rated impulse withstand voltage Uimp: 6000V
  • Rated Residual Operating Current: 0.01A, 0.03A, 0.1A, 0.3A

Applications:

HAROK TYPE B Residual Current Operated Circuit Breaker (RCBO) is an advanced electrical device for over-current and short-circuit protection. It is designed to provide reliable protection and safety for commercial and industrial electrical systems. This RCBO is classified by type of instantaneous tripping, including Type B (3 ~ 5) In and Type C (5 ~ 10) In. It is available in various models, such as VRL22 2P/4P, VRL11, VAL003, VKL003, VDL006, VRL01, VRL02, VRL03, VK007LE, and 1P-4P. It is manufactured in China with rated voltage of AC240V, rated residual making and breaking capacity I△m of 500A, and mechanical life of 2000.

HAROK TYPE B Residual Current Operated Circuit Breaker (RCBO) is a perfect choice for commercial and industrial applications, offering reliable protection and safety. It offers a high degree of over-current and short-circuit protection, as well as improved protection against fire and shock. It can be used in various applications, such as residential, office, industrial, and commercial buildings. This RCBO is designed for reliable performance, offering superior protection and safety. It is easy to install and maintain, making it an ideal choice for any application.

Technical Parameters:

Parameter Value
Product Name RCBO Type B
Frame size rated current Inm 50A
Rated Current 6A 10A 16A 20A 25A 32A 40A 50A
Rated Residual Non-Operating Current 0.005A, 0.015A, 0.05A, 0.15A
Rated residual making and breaking capacity I△m 500A
Rated Voltage AC240V
Standard IEC/EN 61009-1, AS/NZS 61009.1
Poles 1P+N
Classified by Type of Instantaneous Tripping Type B: (3 ~ 5) In, Type C: (5 ~ 10) In
Electrical Life 2000

Customization:

HAROK RCBO Type B Circuit Breaker – Residual Current Operated Circuit Breaker

The HAROK RCBO Type B Circuit Breaker is a Residual Current Operated Circuit Breaker manufactured in CHINA. It is designed to protect circuits against overload, short circuit, and residual current. The models available are VRL22 2P,4P VRL11 VAL003 VKL003 VDL006 VRL01 VRL02 VRL03 VK007LE 1P-4P.

  • Rated Residual Non-Operating Current: 0.005A, 0.015A, 0.05A, 0.15A
  • Poles: 1P+N
  • Rated residual making and breaking capacity I△m: 500A
  • Frame size rated current Inm: 50A
  • Rated Residual Operating Current: 0.01A, 0.03A, 0.1A, 0.3A

Support and Services:

RCBO Type B technical support and services include:

  • Troubleshooting any known issues with RCBO Type B
  • Providing detailed product information
  • Assisting with installation and set-up
  • Providing training and user assistance
  • Providing technical support and advice

Packing and Shipping:

Packaging and Shipping for RCBO Type B

  • Packaging: RCBO Type B will be shipped in sturdy cardboard boxes that are designed to protect the product from any damage during transit.
  • Shipping: RCBO Type B will be shipped via air freight to ensure a quick and safe delivery.

FAQ:

Q&A on HAROK RCBO Type B

Q1: What is HAROK RCBO Type B?

A1: HAROK RCBO Type B is a Residual Current Circuit Breaker with Overcurrent Protection (RCBO) produced by HAROK, with model numbers VRL22 2P,4P VRL11 VAL003 VKL003 VDL006 VRL01 VRL02 VRL03 VK007LE 1P-4P. It is produced in China.

Q2: What are the advantages of HAROK RCBO Type B?

A2: HAROK RCBO Type B provides protection of the electrical circuit against overloads and over-currents, as well as offering protection against electric shocks and fire caused by short circuits. It is designed with a reliable and sensitive trip mechanism for maximum safety.

Q3: What is the application of HAROK RCBO Type B?

A3: HAROK RCBO Type B can be used in residential, commercial and industrial buildings for protection of the electrical circuit against overloads and over-currents, as well as providing protection against electric shocks and fire caused by short circuits.

Q4: What is the rating of HAROK RCBO Type B?

A4: HAROK RCBO Type B has a rated current of 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A and 100A.

Q5: What type of contactor is used in HAROK RCBO Type B?

A5: HAROK RCBO Type B uses a single-pole, two-wire normally open contactor.

Send your message to this supplier
Send Now

VRL01 MINI RCBO Type B With 0.15A Rated Residual Non-Operating Current With Standard IEC/EN 61009-1, AS/NZS 61009.1

Ask Latest Price
Brand Name :
HAROK
Model Number :
VRL01
Place of Origin :
CHINA
MOQ :
3000PCS
Payment Terms :
L/C, T/T
Poles number :
1P+N
Contact Supplier
VRL01 MINI RCBO Type B With 0.15A Rated Residual Non-Operating Current With Standard IEC/EN 61009-1, AS/NZS 61009.1
VRL01 MINI RCBO Type B With 0.15A Rated Residual Non-Operating Current With Standard IEC/EN 61009-1, AS/NZS 61009.1
VRL01 MINI RCBO Type B With 0.15A Rated Residual Non-Operating Current With Standard IEC/EN 61009-1, AS/NZS 61009.1
VRL01 MINI RCBO Type B With 0.15A Rated Residual Non-Operating Current With Standard IEC/EN 61009-1, AS/NZS 61009.1

Yueqing Vorax Electric CO.,LTD

Verified Supplier
3 Years
zhejiang
Since 2003
Business Type :
Manufacturer
Employee Number :
>100
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement