Specifications
Brand Name :
HAROK
Model Number :
VAL003
Place of Origin :
CHINA
Wire Gauge :
14-2 AWG
Product Name :
GFCI Circuit Breaker
Voltage Rating :
120/240VAC
Frequency Rating :
50/60 Hz
CSA Certified :
Yes
Number of Poles :
1 Pole
Description


VAL003 Ground Fault Circuit Interrupter BreakerVAL003 GFCI | Ground Fault Circuit Interrupter

1. General

VAL003 residual current operated circuit breakers are suitable for lines with AC 50/60Hz, rated voltage 240V, 120V, rated current up to 40A and for purposes of residual current protection, overload and short circuit protection. When any personal electric shock occurs or the circuit leakage current exceeds the predetermined value, the residual current operated circuit breaker can automatically cut off the power supply in a very short period of time, so that the safety of persons and electrical equipment can be operated. The residual current operated circuit breaker can be used for infrequent conversion of lines under normal conditions, and applied under occasions such as industrial, and commercial,

high-rise buildings and residential houses.

2. Technical parameters

2.1 The tripping characteristic curves are as shown below. VAL003 Ground Fault Circuit Interrupter Breaker

2.2 Basic parameters

Standard IEC/EN 61009-1
Main Specifications Model No. VAL003
Rated current In 5A, 6A, 10A, 13A, 15A, 16A, 20A, 25A, 30A, 32A, 35A, 40A
Classified by Type of Instantaneous Tripping Type B: (3 ~ 5) In, Type C: (5 ~ 10) In
Poles 1P + N
Type (wave form of the earth leakage sensed) Type AC, Type A
Mechanical features Rated voltage Ue AC240V, AC120V
Frame size rated current In 40A
Rated residual operating current I△n 6mA, 10mA, 30mA, 100mA, 300mA
Rated residual non-operating current I△no 3mA, 5mA, 15mA, 50mA, 150mA
Rated short-circuit breaking capacity Icn 240V: 4500A, 6000A, 10000A 120V: 15000A

Rated residual making and

breaking capacity I△m

500A
Electrical life 2,000
Mechanical life 2,000
Rated impulse withstand voltage Uimp 4000V
Connection From top and bottom, from bottom and top

2.3 The residual current breaking times

In (A) I△n (A) Breaking time when the residual current assumes the following values (s)
I△n 2I△n 5I△n 5A, 10A, 20A, 50A, 100A, 200A, 500A(a) I△t(b)
6~40 0.01, 0.03, 0.1, 0.3 0.1 0.05 0.04 0.04 0.04

a. For tests of 5A, 10A, 20A, 50A, 100A, 200A and 500A, the current values beyond the lower limit of over-current instantaneous tripping are not tested.

B. Tests are done when I△t is equal to the lower limit current of over-current instantaneous tripping of type B and type C.

2.4 The over-current protection characteristics

No. Rated current In (A) Initial state Test current (A) Specified time (t) Expected result Remarks
a 6 ~ 40 Cold state 1.13 In t ≥ 1h Non-tripping
b Immediately after sequence a 1.45 In t < 1h Tripping Increase to the specified current within 5s after test item a.
c Cold state 2.55 In 1s < t < 60s Tripping
d Cold state 3 In t ≥ 0.1s Non-tripping Type B
5 In t < 0.1s Tripping
5 In t ≥ 0.1s Non-tripping Type C
10 In t < 0.1s Tripping

3. Outline and installation dimensions (mm)

___________________________________________________________________________________________________________________
VAL003 Ground Fault Circuit Interrupter BreakerVAL003 Ground Fault Circuit Interrupter Breaker

Product Description:

GFCI Circuit Breaker is a type B RCBO (Residual Current Breakers with Overload) circuit breaker which provides reliable ground fault protection. It is rated for 120/240VAC and offers an indicator light to indicate when it is on or off. It is easy to install with its plug-in mounting type. With this GFCI circuit breaker, you can be assured of a safe and reliable current flow.

Features:

  • Product Name: GFCI Circuit Breaker
  • Trip Type: Thermal Magnetic
  • CSA Certified: Yes
  • Interrupt Rating: 10kA
  • Ground Fault Protection: Yes
  • Terminal Type: Push-in
  • RCBO Circuit Breaker

Applications:

Introducing HAROK's GFCI Circuit Breakers

HAROK is proud to introduce its GFCI Circuit Breaker line of products, including the VRL01, VRL02, VRL03, VRL11, VAL003, VKL003, VDL006, and VRL22 models. Providing ground fault protection, these GFCI Circuit Breakers are UL listed and mounted with a plug-in type. An indicator light allows for improved visibility and safety.

GFCI Circuit Breakers are an ideal choice for a variety of applications, such as residential and commercial buildings. They are also ideal for use in both RCBO and RCBO Type A Circuit Breakers, providing superior protection in a wide range of industrial and commercial settings.

HAROK GFCI Circuit Breakers provide superior performance and advanced design features to ensure increased safety and reliability. With advanced surge protection and overload protection technology, these GFCI Circuit Breakers are a must-have for both residential and commercial settings.

For all your GFCI Circuit Breaker needs, choose HAROK. Our GFCI Circuit Breakers provide reliable protection and are backed by our industry-leading customer service and support.

Technical Parameters:

Wire Gauge 14-2 AWG
Voltage Rating 120/240VAC
Product Name GFCI Circuit Breaker
Interrupt Rating 10kA
CSA Certified Yes
Number of Poles 1 Pole
NEMA Rating NEMA 1
Mounting Type Plug-in
Amperage Rating 15A
UL Listed Yes
Ground Fault Circuit Interrupter (GFCI) Yes
RCBO Type B Yes

Customization:

HAROK GFCI Circuit Breaker

Brand Name: HAROK

Model Numbers: VAL003,

Place of Origin: CHINA

UL Listed: Yes

Frequency Rating: 50/60 Hz

Number of Poles: 1 Pole

Mounting Type: Plug-in

Wire Gauge: 14-2 AWG

HAROK GFCI Circuit Breaker for Ground Fault Circuit Interrupter (RCBO)

HAROK GFCI Circuit Breaker is a reliable, UL-listed circuit breaker for ground fault circuit interrupter (RCBO) applications. Our GFCI circuit breakers feature a frequency rating of 50/60 Hz, a 1 pole mounting type, and a wire gauge of 14-2 AWG.

Packing and Shipping:

Packaging and Shipping for GFCI Circuit Breaker

GFCI Circuit Breaker must be packaged and shipped in accordance with the following instructions.

  • The GFCI Circuit Breaker must be secured in a box that is large enough to accommodate the product and any accompanying accessories.
  • The box must be closed and sealed securely with packing tape.
  • The box must be clearly marked with the product name and address of the sender.
  • The box must be sent via a traceable delivery service.
  • The box must be stored in a dry and cool location prior to shipment.

GFCI | Ground Fault Circuit Interrupter

Send your message to this supplier
Send Now

VAL003 Ground Fault Circuit Interrupter Breaker

Ask Latest Price
Brand Name :
HAROK
Model Number :
VAL003
Place of Origin :
CHINA
Wire Gauge :
14-2 AWG
Product Name :
GFCI Circuit Breaker
Voltage Rating :
120/240VAC
Contact Supplier
VAL003 Ground Fault Circuit Interrupter Breaker
VAL003 Ground Fault Circuit Interrupter Breaker
VAL003 Ground Fault Circuit Interrupter Breaker
VAL003 Ground Fault Circuit Interrupter Breaker

Yueqing Vorax Electric CO.,LTD

Verified Supplier
3 Years
zhejiang
Since 2003
Business Type :
Manufacturer
Employee Number :
>100
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement