Specifications
Brand Name :
HAROK
Model Number :
VKL11
Place of Origin :
CHINA
Certification :
NF, SEMKO, VDE, KEMA
MOQ :
1000
Packaging Details :
PAPER CARTON
Delivery Time :
4-6 weeks after payment
Payment Terms :
FOB NINGBO or SHANGHAI
Supply Ability :
100,000 PCS PER MONTH
Installation Method :
Cable/Pin-type busbar
Trip Time :
≤0.1s
Rated Voltage :
240V/415V
Weight :
According To The Product Model
Protection Grade :
IP20
Insulation Voltage :
≥2KV
Rated Sensitivity :
30mA/100mA/300mA
Material :
PA66
Description

VKL11 Earth Leakage Circuit Breaker(ELCB) ISI mark
VKL11 ELCB Earth Leakage Circuit Breaker With ISI Mark 10KA Made Of PA66

1. General

1.1 Function

Control electric circuits.

Protect people against indirect contacts and additional protection against direct contacts.

Protect installations against fire hazard due to insulation faults.

Residual current circuit breakers are used in housing, tertiary sector and industry.


1.2 Selection

Detectable wave form

ELCB Type Suitable for electrical networks with
Pulsated DC current Harmonics Switching surges
AC CLASS No No No
A CLASS Yes No No
S, ASi CLASS Yes Yes Yes

A Class ELCB may not work satisfactorily in electrical network distributed by harmonics & switching transients and may give nuisance triping.

AC class

Tripping is ensured for slowly increasing sinusoidal AC residual currents

A class

Tripping is ensured for sinusoidal AC residual currents and for pulsed DC residual currents, whether applied suddenly or increasing slowly.

ASi Type - Full type A features + Si: Super immused (High immunity to unwanted tripping)

Tripping is ensured not only for sinusoidal AC residual currents but also for pulsed DC residual currents whether applied suddenly or increasing slowly. S, G/SI type with filters against spurious tripping caused by harmonics and transient surges. With the impact of 8/20us surge 3000A, this high immunity RCCB will still be in stable status.

Note: Our ASi type includes G/KV function and Si function.


1.3 Approvals and certificates

We certify that the ELCB has been tested for the following routine tests as per IS: 12640 (Part 1):2016 and found to be complying

with the requirements.

1. Verification of the operating characteristic as per Seq. - D0 CL9.9

2. Verification of the operation of the test device at the limits of rated voltage as per Seq. - D1 CL9.16

3. High Voltage Test as per D.3 of Annex D

4. Test for standard values of break time and non- actuating time as per CL 5.3.12 (table -1)

VKL11 ELCB Earth Leakage Circuit Breaker With ISI Mark 10KA Made Of PA66

Tripping sensitivity
10mA - precision instrument leakage protection and bathroom use.
30mA - additional protection against direct contact.
100mA - co-ordinated with the earth system according to the formula I△n < 50/R, to provide protection against indirect contacts;
300mA/500mA - protection against indirect contacts, as well as fire hazard.
Tripping time
Instantaneous
It ensures instantaneous tripping(without time-delay).
Short time delay Si, G, KV
It ensures any tripping at least 10ms.
Si: Super immunised (High immunity to unwanted tripping).
Selective VKL11 ELCB Earth Leakage Circuit Breaker With ISI Mark 10KA Made Of PA66
It ensures total discrimination with a non selective ELCB(RCCB) placed downstream.
VKL11 ELCB Earth Leakage Circuit Breaker With ISI Mark 10KA Made Of PA66



ELCB | Earth Leakage Circuit Breaker

2. Technical parameters

Standard IEC/EN 61008-1 AS/NZS61008.1
Electrical features Model No. VKL11
Poles 2P, 4P
Rated current In 16A, 25A, 32A, 40A, 63A, 80A, 100A
Rated Sensitivity I△n 10mA(2P/4P 16A,25A.32A/40A), 30mA, 100mA, 300mA
Rated voltage Ue 2P: 240V 4P: 415V
Insulation voltage Ui 415V
Rated frequency 50/60 Hz
Rated residual making and breaking capacity I△m 1500A
Short-circuit current Inc=I△c 6000A, 10000A
Type (wave form of the earth leakage sensed) AC, A, ASi, S
break time under I△n ≤0.1s(Normal type), 10ms~300ms(ASi type). 150ms~500ms(S type)
Rated impulse withstand voltage(1.2/50) Uimp 4kV
Dielectric test voltage at ind. Freq. for 1 min 2.5
Pollution degree 2
Mechanical features Electrical life ≥2000
Mechanical life ≥2000
Fault current indicator Yes
Terminal protection degree IP20

Ambient temperature (with

daily average≤35℃)

-25℃ to 50℃
Storage temperate -30℃ to 70℃
Installation Terminal connection type Cable/Pin-type busbar
Terminal size top/bottom for cable 25-35 mm²
18-3/18-2 AWG
Terminal size top/bottom for busbar 10/16 mm²
18-8/18-5 AWG
Tightening torque 2.5 N·m
22 In-Ibs.
Mounting On DIN rail EN 60715 (35mm) by means of fast clip device
Connection From top and bottom



3. Outline and installation dimensions (mm)

VKL11 ELCB Earth Leakage Circuit Breaker With ISI Mark 10KA Made Of PA66VKL11 ELCB Earth Leakage Circuit Breaker With ISI Mark 10KA Made Of PA66

ELCB | Earth Leakage Circuit Breaker

Product Description:

ELCB (Earth Leakage Circuit Breaker) is an electrical safety device used to protect people and property from electrical shock. it is designed to detect small currents in the ground and quickly interrupt the circuit when a fault is detected. VORAX ELCB is UL-certified, and it has passed rigorous tests to meet the requirements of NF, SEMKO, VDE, and KEMA safety standards, ensuring maximum safety for users. It is suitable for operating environment temperature from -25℃~+50℃. The weight of the product varies according to the model, and it can be installed both through Cable and Pin-type busbar.

Features:

  • Product Name: ELCB Earth Leakage Circuit Breaker
  • Type: TYPE AC, TYPE A, TYPE ASi
  • Installation Method: Cable and Pin-type busbar
  • Insulation Voltage: ≥2KV
  • Weight: According To The Product Model
  • Rated Frequency: 50/60Hz
  • Operating Environment Temperature: -25℃~+50℃

Applications:

HAROK VKL11 Earth Leakage Circuit Breaker is a reliable and advanced electrical protection device. It meets NF, SEMKO, VDE and KEMA safety standards. It is made of high-grade materials and components, and features high safety, reliability, and stability. Its rated current is 6A-100A, rated voltage is 220V/380V, and rated sensitivity is 30mA/100mA/300mA/500mA. It can be used in Type F, Type A, Type AC, and Type ASi environments. It can be installed by fixed or plug-in methods. One package contains 1000 pieces, and it is usually packaged in paper cartons. The delivery time is usually 4-6 weeks after payment. FOB NINGBO or SHANGHAI payment terms are accepted. The monthly supply ability of this product is 100,000 PCS, and its weight is according to the product model.

Technical Parameters:

Attribute ELCB
Type Type A Type AC Type ASi
Rated Sensitivity 30mA/100mA/300mA
Rated Breaking Capacity 10KA
Installation Method Cable and Pin-type busbar
Protection Grade IP20
Rated Voltage 240V/415V
Material PA66
Certificate NF, SEMKO, VDE, KEMA
Rated Current 6A-100A
Weight According To The Product Model
Insulation Voltage ≥2KV

Customization:

ELCB Earth Leakage Circuit Breaker
  • Brand Name: HAROK
  • Model Number: VKL11
  • Place of Origin: CHINA
  • Certification: NF, SEMKO, VDE, KEMA
  • Minimum Order Quantity: 1000
  • Packaging Details: PAPER CARTON
  • Delivery Time: 4-6 weeks after payment
  • Payment Terms: FOB NINGBO or SHANGHAI
  • Supply Ability: 100,000 PCS PER MONTH
  • Protection Grade: IP20
  • Rated Current: 6A-100A
  • Certificate: NF, SEMKO, VDE, KEMA
  • Insulation Voltage: ≥2KV
  • Types: ELCB Type A Type AC Type ASi, Earth Leakage Circuit Breaker

Packing and Shipping:

Packaging and Shipping ELCB Earth Leakage Circuit Breaker

ELCB Earth Leakage Circuit Breaker should be packed in a strong, sturdy box with plenty of cushioning material. This box should be sealed and labeled with the product name and weight.

The box should then be placed inside a larger box with cushioning material around it. The larger box should also be sealed and labeled with the product name and weight.

Shipping should be done via a reputable carrier such as UPS or FedEx. All packages should be tracked and insured for the full value of the product.

Send your message to this supplier
Send Now

VKL11 ELCB Earth Leakage Circuit Breaker With ISI Mark 10KA Made Of PA66

Ask Latest Price
Watch Video
Brand Name :
HAROK
Model Number :
VKL11
Place of Origin :
CHINA
Certification :
NF, SEMKO, VDE, KEMA
MOQ :
1000
Packaging Details :
PAPER CARTON
Contact Supplier
video
VKL11 ELCB Earth Leakage Circuit Breaker With ISI Mark 10KA Made Of PA66
VKL11 ELCB Earth Leakage Circuit Breaker With ISI Mark 10KA Made Of PA66
VKL11 ELCB Earth Leakage Circuit Breaker With ISI Mark 10KA Made Of PA66

Yueqing Vorax Electric CO.,LTD

Verified Supplier
3 Years
zhejiang
Since 2003
Business Type :
Manufacturer
Employee Number :
>100
Certification Level :
Verified Supplier
Contact Supplier
Submit Requirement