NO. | Items | Characteristics | Testing Methods | |
1 | Nominal Voltage | 12.8V | Follow | |
2 | Nominal Capacity | 12Ah | Follow | |
3 | Minimum Capacity | 11.4Ah | Follow | |
4 | Battery internal Impedance | Internal Impedance≤60mR | Internal Impedance Testing Machine(1kHz ) | |
5 | Shipment Voltage | 12.8~13.6V | Multi-meter | |
6 | Dimension | Length | MAX: 150*85*85mm | Vernier caliper |
Width | ||||
Height | ||||
gross weight | 1.8kg | electronic scale | ||
7 | Working Temperature | Charge | 0~45℃,45~85%RH | Temperature & Humidity Instruments |
Discharge | -20~55℃,45~85%RH | |||
8 | Storage Temperature & Humidity Range | Short: above one month | -20~+55℃,45~85%RH | Temperature & Humidity Instruments |
Medium: above three months | 0~+45℃,45~85%RH | |||
Long:above one year | +5~+30℃,45~85%RH | |||
9 | Allowed maximum continuous charge current | 6A | Multi-meter | |
10 | Allowed maximum continuous discharge current | 12A | Pulse current 300A/2S | |
11 | Allowed maximum reverse charge voltage | NO Allowed | / | |
12 | Allowed maximum charge voltage | 14.6±0.1V | Multi-meter | |
13 | Discharge cut-off voltage | 9±1.0V | Multi-meter |
No. | Items | Standards | Testing Methods |
1 | Short-Circuit | The battery should be no remarkable breakage, distortion. And charge normally. | Use a resistor with less than 20mΩ to make the battery short circuit for 1 hour. The appearance and characteristics are normal. |
2 | Over Discharge Protection Test | The battery should be no remarkable breakage, distortion. Appearance and charge are normal. | Discharge the battery at the rate of 0.33C with the load of 30Ω for 24h. Charging for 10sec with specified adapter, and check the voltage (≥8V). |
3 | Impact Test | The battery should be no explosion or catch fire. | Place a full charged battery on a flat and put a stainless steel stick (Diamond 7.9mm) in the middle of the battery upright. Beat the steel stick with 9.1Kg. |
5. Warning & Tips
Please read and follow the specification and caution remarks on battery surface before use the battery. Improper use may cause heat, fire, rupture, damage or capacity deterioration of the battery. Shenzhen Topband Battery Co., Ltd. Describes is not responsible for any accidents caused by the usage without following our specification.