Battery Energy Storage System 7.68KWh 48V 150Ah LiFePO4 for Solar System
1. Features
◆ Wall mounted;
◆ High safety LiFePO4 battery;
◆ Long cycle life (≥4000cycles)
◆ Advanced High/Low-temperature cycle performance
◆ Intelligent LED & LCD display;
◆ With RS485; CAN communication optional;
◆ Support multi-battery modules in parallel;
◆ Support WIFI communication & cloud platform via APP;
2. Battery Specification
Items | Description |
Nominal voltage | 51.2V |
Nominal capacity | 150Ah |
Nominal energy | 7.68 KWh |
Operation temperature(cells temperature) | Discharge: -20℃~60℃(-4℉~140℉) Charge: 0℃~45℃(32℉~113℉) |
Charging Voltage | Normal charging: 57.6V; Float Charging: 55.2V |
Max. charging current | 150A |
End discharging voltage | 43.2V |
Max. discharging current | Continuously: 150A; Peak: 500A(3S),750A(1S) |
Cycle life@0.33C | ≥2000cycles (DOD100%); ≥4000cycles (DOD80%) |
Life time | 10years |
Dimensions(Width/Height/Depth) | 612*782*227 mm |
Battery module weight | 107kg |
Transport standards | Meet UN38.3 |
Self-discharge rate | ≤2% per month |
Storage Temperature & Humidity Range | -10~30℃, 45%~85%RH |
3. BMS Function
Items | Description | |
Over charge | Over-charge alarm for each cell | 3.55±0.03V |
Over-charge protection for each cell | 3.75±0.03V, Delay time:1s | |
Over-charge release for each cell | 3.40±0.03V | |
Over-charge alarm for total voltage | 56.8V±0.5V | |
Over-charge protection for total voltage | 60.0V±0.5V, Delay time:1s | |
Over-charge release for total voltage | 54.4V±0.5V | |
Over-charge release method | Under the release voltage | |
Over discharge | Over-discharge alarm for each cell | 3.00±0.03V |
Over-discharge protection for each cell | 2.70±0.03V, Delay time:1s | |
Over-discharge release for each cell | 3.10±0.03V | |
Over-discharge alarm for total voltage | 48.0V±0.5V | |
Over-discharge protection for total voltage | 43.2V±0.5V, Delay time:1s | |
Over-discharge release for total voltage | 49.6V±0.5V | |
Over-discharge release method | Charge to recovery | |
Over current | Charge over current alarm | 165±5A |
Charge over current protection | 180±5A, Delay time:5s | |
Charge over current release method | Auto release after 1min; | |
Discharge over current alarm | 165±5A | |
Discharge over current protection | 180±10A, Delay time:1s | |
Over current release method | Auto release after 1min | |
Over temperature | Charge over temperature alarm | 50±3℃ |
Charge over temperature protection | 55±3℃ | |
Charge over temperature release | 45±3℃ | |
Discharge over temperature alarm | 60±3℃ | |
Discharge over temperature protection | 65±3℃ | |
Discharge over temperature release | 55±3℃ |
Under temperature | Charge under temperature alarm | 5±3℃ |
Charge under temperature protection | 0±3℃ | |
Charge under temperature release | 5±3℃ | |
SOC | LOW SOC Alarm: 10% | |
LCD | Battery information display: Voltage, Power, SOC, Cycles, Temperature, Residual energy, Errors/Alerts | |
Communication | with RS485; Can-bus; | |
monitoring | WIFI, poll all of the WiFi enabled batteries on the same sub-network | |
Series & Parallel connection | Prohibit serial connection; Support max. 8pcs in parallel. |
4. Product pictures
LCD display:
6. Transportation & Storage
* Based on the character of cell, proper environment for transportation of LiFePO4 battery pack need to be created to protect the battery.
* Battery should be stayed in the warehouse 15℃~35℃ where is dry, clean, shade, and well-ventilated.
* The battery should be stored in 50% SOC during transportation.
* The battery need to be charged every 6 months if out of use
* Keep the battery against dropping, turning over and serious stacking during loading
7. Warning & Tips
Please read and follow the specification and user manual before use the battery. Improper use may cause heat, fire, rupture, and damage or capacity deterioration of the battery. SHENZHEN TOPBAND BATTERY CO., LTD. shall not be responsible for any accidents caused by the usage without following our specification.
² The battery must be far away from heat source, high voltage, and avoid to be exposed in sunshine for long time.
² Never throw the battery into water.
² Do not put the battery in a charger or equipment with wrong terminals connected.
² Never connect the positive and negative of battery with metal.
² Avoid excessive physical shock or vibration. Don't hit, fall, stamp on the battery.
² Without the permission of the manufacturer and guidance, forbidden to remove or to assemble the battery
² Do not use the battery mixed with other different manufacturer, type, or model batteries.
² Keep the battery against high temperature. Otherwise, it will cause battery heat, get into fire or lose some function and reduce the life.
² When battery run out of power, please charge your battery timely (≤15day).
² Please use the matched or suggested charger for this battery.
² If battery emits peculiar smell, heating, distortion or appears any abnormity during working or storage, please stop using and take it out from device.
² If the battery leaks and get into the eyes or skin, do not wipe, instead, rinse it with clean water and see doctor immediately.
² Please keep it far away from children or pets.
² Do not put disuse battery into a fire or water.
² It is strictly prohibited any series between the battery packs. Any requirements on serials connection, please contact TOPBAND for details.
8. Operation instruction
Charge and discharge
1. Charging current: Do not surpass the largest charging current that specification stipulated.
2 .Charging voltage: Do not surpass the highest limited voltage that specification stipulated.
3 .Charging temperature: Within temperature scope that specification stipulated.
4. Charge with constant current, then with the constant voltage, no reverse charge, which is dangerous
5. Special notes: Short time over discharge or over charge doesn't affect the use of the battery, but for a long period of time over discharge or over charge can cause the function of the battery fail, or the battery can't use permanently and appear serious safety hazards. Please follow the recommended floating model parameters when it needs long time floating. When the Battery not in use for a long time, it can also discharge because of its own self-discharge characteristics, to prevent the occurrence of over discharge, battery should maintain a certain capacity; maintain the voltage at 50% state of SOC.
9. Other Chemical Reaction
Because batteries utilize a chemical reaction, battery performance will deteriorate over time even if stored for a long period of time without being used. In addition, if the various usage conditions such as charge, discharge, ambient temperature, etc. are not maintained within the specified ranges, the life expectancy of the battery may be shortened or the device in which the battery is used may be damaged by electrolyte leakage. If the discharge time is much shorter than the normal after full charged, even battery is charged correctly, and this may indicate it is time to change the battery.