9HP R404a Air Cooling Condensing Unit Refrigeration Unit For Cold Storage
Products Feature :
1 ) Adopt world famous brand Copeland hermetic compressor , with high reliability , less vibration and low noise ;
2 ) Adopt cabinet structure , attractive appearance , compact structure easy installation;
3 ) Condenser fan adopt high quality motor,high efficiency and low noise;
4 ) Adopt copper tube aluminum fin condenser , with more face area , high heat exchange efficiency and long service life .
5 ) Can meet high , medium and low temperature requires .
Air - Cooled Refrigeration Unit Technical parameters :
1 . Condenser Details :
Qty Of Fan ( piece ) | Air Volume ( m3 / h ) | Power of Fan ( W ) |
1 | 1 * 12200 | 1 * 800 |
2 . Refrigerant Capacity Of Compressor :
a. Evaporating Temperature - 5 ℃
Cooling Capacity | 20700 W |
Power | 8840 W |
b . Evaporating Temperature - 12 ℃
Cooling Capacity | 16150 W |
Power | 8410 W |
3 . Coupling :
Tube Coupling : 5 / 8 〞
Suction Coupling : 1 - 3 / 8 〞
4 . Overall Dimensions :
Length ( L ) : 1100mm
Width ( B ) : 900mm
Height ( H ) : 980mm
5 . Mounting Dimensions :
Length ( D ) : 750mm
Width ( E ) : 870mm
Standard configuration of units : compressor , condenser , liqid receiver , pressure controller , pressure gauge , filter , solenoid valve and wiring box , etc .
Note :
1 . Cooling capacity in the form iscalculated when the ambiernt temperature is 32℃.
2 . Configuration can be added according to customers' requirements .
3 . When the compressor using refrigerant R22,and evaporating temperature lower than - 15 ℃ cylinder head fan must be installed . When the evaporating temperature below - 25 ℃ the compressor hydrojet system also must be installed .
4 . When the compressor using refrigerant R404a ,and evaporating temperature lower than - 20 ℃ cylinder head fan must be installed .