Intelligent XR03CX-5N0C1 230V 50HZ Digital Controllers original Thermostat DIXELL
1, Product Description:
Model NO.: XR03CX-5N0C1
Cooling System: Air Cooling
Cylinder Position: Vertical
Nominal motor power [HP]: depends on compressor
Displacement [m³/h]:1.8
Weight [kg]: 0.65
Oil charge [dm³]:No
Electrical data :
Power supply [V/~/Hz]: 110-220V/3/50Hz
Locked rotor current [A]:2.15
Max. operating current [A]: 2.5
Winding resistance [Ω]: 1.26
Connections:
Suction line: 5/8"
Discharge line: 1/2"
Technical parameters: ABS matte color flame retardant plastic; External dimension: front 32x74mm; Deep 60 mm; Mounting dimension: fixed on the panel with an opening of 71x29mm; Overall protection level: IP20; Front panel protection grade: IP65; Terminal: bolt compression, wire diameter ≤ 2.5mm2; Power supply: according to the model: 12Vac/dc,±10%; 24 vac/dc, plus or minus 10%; 230 vac plus or minus 10%, 50/60 hz; 110 vac plus or minus 10%, 50/60 hz. Please refer to the name tag on the product. Power consumption: Max. 3VA; Display: 2-bit red digital tube, 14.2 mm high; Input: up to 2 NTC input digital input: passive switch output relay: compressor, 8 (3) A SPST, Italy elf electronic thermostat XR06CX instruction) _word document read online and download _ document https://www.wendangwang.com/doc/8e010377ca47a278d089f82c/3 250 vac or SPST 16 (6) A (8), 20 A 250 vac or 250 vac defrosting: SPDT 8(3) A, 250Vac evaporator fan: SPST 8(3) A, 250Vac or SPST 5(2) A data storage: electrically erasable electrically writable memory (EEPROM). Control level: 1B; Environmental protection level: 2; Software level: A; Maximum insulation voltage: 2500V; Overvoltage class: II; Operating temperature: 0~60°C; Storage temperature: -30~85° c. relative humidity: 20~
No = maintain the original state (the output state is unchanged); Fn= fan off only; CP= only compressor is closed; FC= fan compressor is off. Once the door is opened, the alarm of the back door set by the delay "di" parameter will be activated, and the "dA" character will be displayed on the screen. If rd=y is automatically adjusted, the control will be restarted. When the digital switch input is invalid, the alarm will stop immediately. When the door opens the alarm, the high and low temperature alarm will fail. General alarm (iF=EA) once the digital input alarm is activated and the thermostat waits for the "di" parameter setting time, the "EA" alarm information will be displayed iF the digital input is still valid. All relay output state is unchanged, when the digital input is invalid, the alarm will stop immediately. Serious alarm (iF=bA) once the digital input alarm is activated, the thermostat waits for the time when the "di" parameter is set, and iF the digital input is still valid, the "CA" alarm information will be displayed. All relay output contacts are disconnected. If the digital input is invalid, the alarm will stop immediately. Activate defrost (iF=dF) when defrost conditions allow, once the digital input is effective, a defrost will be activated. When the defrost is over, iF the digital input is invalid, the defrost will be withdrawn and normal temperature control will be restored, otherwise the thermostat will wait for the time set by "dd". Control type conversion: heating and cooling (iF=Hc) this function is not applicable to this model, please do not select.
3.Product details
Model | XR03CX-5NOC1 |
Brand | DIXELL |
Power | 110-220V/3/50Hz |
Displacement | 6.8cc/rev |
Capacity | 10kBtu/h |
COP | 7.5W/W |
Package | 1pc/box package |
Certification | CE |
Application | Air conditioning, HVAC system |
4. Product qualification
Certificate, certification, patent certificate:
1)."Quality Management System Certification"
2)."Shenzhen Science and Technology Enterprise Certification"
3)."Refrigeration Equipment Air Conditioning Maintenance and Installation Enterprise Qualification Certificate"