Specifications
Brand Name :
KAIXIANG
Model Number :
AC10.5KV-1800KW
Certification :
ISO9001
Place of Origin :
HEBEI CHINA
MOQ :
ONE SET
Price :
negotiable
Payment Terms :
L/C, D/A, D/P, T/T, Western Union, MoneyGram,
Supply Ability :
10 SET ONE MONTH
Delivery Time :
ONE MONTH AFTER GET DEPOSIT
Packaging Details :
WOODEN CASE
Resistive Load :
100KW*2.200KW*1.400KW*2.600KW*1
Rating Voltage/Frequency :
10.5kV/50Hz, 3 phase 3 wire
Load Tolerance (overall) :
±3%
Fan &Control Voltage :
External AC 3 phase 4 line, 380V/50Hz
Size :
6058 * 2438 * 2591 mm
Max load power :
1800 KW
Description

In Australia 10.5KV 1800KW Medium Voltage Load Bank For Generator Testing

Product Description

1. our load bank an accurately test output power and load capacity with all kinds of generators.

2. System consists of testing/control and load bank, mainly includes AC load bank, data capture system, auto load/unload control system, heat dissipation device, assist control and PC software.

3. User can control load bank through local control panel, also through software


Technical Parameters

Rating Voltage/Frequency 10.5kV/50Hz, 3 phase 3 wire
Rated power 1800kw
Max load power 30MW
Load Resolution Resistive Load: 100KW*2.200KW*1.400KW*2.600KW*1
PF(Power Factor) 1
Load Tolerance (each step) ±5%
Load Tolerance(overall) ±3%
Display Precision 0.5 class
Control Power 380VAC/50Hz,
Weight About 8000kgs/set
Wire Connection

Load power supply input——Copper bar (star coupling)

Control power supply input——Connector-bar

Size 6058*2438*2591mm


Technology Advantages

1. Communication Mode:RS485/ USB or RS232 interface for communication.

2. Load Mode: manual load or automatic load

3. Manual Load: input power and power factor, and load according to the preset value.

4. Automatic Load: set several load stages and duration, then complete the process according this stages automatically. 0%- 25%,- 50%,- 75%, -100%


Application

1. Manufacturers of standby power generators commonly use load banks to test and tune newly assembled units

2. generator has been set up in a test cell within the factory, a test engineer uses the load bank to apply a discrete, selectable electrical load to the generator and measure the response stability and endurance.

3. During this process, the test engineer calibrates and adjusts the generator performance to ensure it meets the intended product specifications and tolerances.

3 Phase 3 Wire High Power Resistor Load Bank For Australia Generator Testing

Send your message to this supplier
Send Now

3 Phase 3 Wire High Power Resistor Load Bank For Australia Generator Testing

Ask Latest Price
Brand Name :
KAIXIANG
Model Number :
AC10.5KV-1800KW
Certification :
ISO9001
Place of Origin :
HEBEI CHINA
MOQ :
ONE SET
Price :
negotiable
Contact Supplier
3 Phase 3 Wire High Power Resistor Load Bank For Australia Generator Testing

Hebei Kaixiang Electrical Technology Co., Ltd

Active Member
7 Years
hebei, shijiazhuang
Since 1994
Business Type :
Manufacturer, Exporter, Trading Company, Seller
Total Annual :
10000000-15000000
Employee Number :
120~130
Certification Level :
Active Member
Contact Supplier
Submit Requirement