400V 200kW Automatic Portable Load Bank With Grey Colour and High Performance
Introduction
AC400-200kW Load Bank system can accurately test output power and load capacity with all kinds of generators, generator sets for all main electrical parameters including the dynamic parameters tested.
Applications
Kaixiang has more than 20 years of professional experience in testing and commissioning of generators, batteries and UPS. Our high capacity load banks are exported to more than 20 countries around the globe in a wide variety of applications such as military ships, offshore platforms, data centre, power stations, generator manufacturers and research institutes.Its customers widely distributed in America, Mexico, Netherlands, Australia, Singapore, Israel, Poland, Saudi Arabia, UAE, Egypt, Indonesia, Malaysia,Vietnam, The Philippines, Cambodia, Sudan etc.
Kaixiang load banks operate at the actual output voltage of medium voltage generators and therefore do not require large step-down transformers, which reduces the overall package size and installation costs. Kaixiang’s quality system is certified to meet ISO9001:2015 standards. Kaixiang AC load banks certified by CE certificate.
Technical specification
Technical Parameters | |
Rating Voltage/Frequency | AC 400V/50Hz, 3 phase 5 wire |
Max Load Power | Resistive Load: 200kW |
Load Step | Resistive Load. 9 steps; 1,2,2,5,10,10,20,50,100kW |
Power Factor | 1 |
Load Tolerance(each step) | ±5% |
Load Tolerance(overall) | ±3% |
Display Precision | 0.5 class |
Control Power Supply | AC220V/50Hz Single Phase |
Wire Connection |
Load Power Supply Input——Copper bar (star connection) Control power supply input——Amphenol connector |
Communication Interface | RS485 |
Working Mode | Continuous Working |
Cooling | Forced air cooling,Horizontal inlet air,Horizontal outlet |
Transportation | Hoisting, there are lifting lug in top of casing and casters in bottom of load bank |
Size |
Approximately; 570*1450*870 (Width *Length *Height) |
Weight | Approximately; 300kg |
Operating Environment Parameter | |
Ambient Temperature | -10℃~+50℃ (14℉~122℉) |
Relative Humidity | ≤95% |
Altitude | ≤2500 meters |
Atmospheric Pressure | 86~106kPa |
Main features
Load testing: load power that not beyond the rated power, testing and display stable state 3 phases voltage, current, active power, frequency, working time, etc of generator sets.
Load/unload with one key: Whether manual control and software control, user can preset the power, then press load master button. Load bank loaded according to preset power to avoid load fluctuation during the power changing.
Control Pattern: user can choose local control and intelligent control.
Local Control: There is local control panel with several power steps, user can load/unload by button.
Intelligent Control: Through data processing software in PC, user can make automatic load, to display, record and manage the testing data, to form curves, tables, also to print them.
Control Pattern interlock, there is control pattern switch, when choose one control pattern, operation of other pattern is invalid, avoid the clash.
Local meter display data: local meter can display 3 phases voltage, current, active power, frequency and so on.