Specifications
Brand Name :
Kaixiang
Model Number :
AC400-3000KVA
Certification :
ISO9001
Place of Origin :
China
MOQ :
1 set
Price :
negotiable
Payment Terms :
L/C, T/T, Western Union
Supply Ability :
40 Sets per Month
Delivery Time :
Within 30 working days
Packaging Details :
Container for Load bank
Power factor :
0.8(lag)
Max Protection Grade :
IP54
Rated Voltage :
400 VAC
Dimensions :
6058mm×2350mm×2591mm(L×W×H)
Insulation :
F class
Frequency :
50HZ
Description

AC400-3000KVA 3 Phase Load Bank With Blue Colour And High Performance

Product description

(1) According to the special requirements of users on site, in the agreement the technical standards of AC400-3000KVA Resistive Inductive Load Bank (hereinafter referred to as "system") and its accessories are proposed including their function, performance, usage, structure, installation and test to provide users with a high efficient and reliable choice, in order to meet the need for generator load test.

(2) The system consists of 1 sets of 3000KVA Load Bank, The resistive power is 2400kW, the inductive power is 1800KVAR. The system is made up of two parts of measurement & control and load, mainly including the medium voltage dry type AC load bank, automatic data acquisition system, automatically loading and unloading control system, the cooling device, auxiliary control, remote control box and PC software and so on.

Technical Parameter

System Parameter
Rating voltage/frequency 400V, 3 phase 4 wire 50Hz
Max Load Power

Apparent Power: 3000KVA

Resistive Load: 2400kW

Inductive Load: 1800KVAR

Load Resolution

Resistive Load: 20 steps 1kW,2kW,2kW,5kW,10kW,10kW,20kW,50kW,100kW,200kW,200kW,200kW, 200kW,200kW,200kW,200kW,200kW,200kW,200kW,200kW

Inductive Load: 17 steps

1KVAR,2 KVAR, 2KVAR, 5KVAR, 10KVAR, 10KVAR, 20KVAR, 50KVAR, 100KVAR, 200KVAR, 200KVAR, 200KVAR, 200KVAR, 200KVAR,200KVAR,200KVAR,200KVAR

Power Factor 0.8(lag)
Load Tolerance (each step) ±5%
Load Tolerance (overall) ±3%
Fan &Control Voltage External AC 3 phase 4 line, 380V/50Hz
Wire Connection

Load bank input——Copper bar (star coupling ”Y”)

Control power input——Connector-bar

Communication Interface RS485,RS232
Insulation F
Max Protection Grade IP54
Duty Cycle Continuous
Cooling Forced air cooling, by Axial Fan; horizontal inlet air, vertical exhaust cooling
Enclosure Container type,with a ladder, air inlet and outlet with mesh enclosure and protection door
Internal Lighting Adequate internal lighting will be provided
Transportation Hoisting, there are lifting lug in top of casing
Color Grey RAL7035 or as required
Dimensions 6058mm×2350mm×2591mm(L×W×H)
Operating Environment Parameter
Workplace Outdoor
Ambient Temperature -10℃~+50℃
Relative Humidity ≤95%
Atmospheric Pressure 86~106kPa
Brands of Main Components
Contactor Schneider
Fuse Miro
PLC Siemens
Alloy Resistor Kaixiang
Data Processing Software Kaixiang
Product Advantage

(1) Overvoltage Protection: the input load voltage is over the safe threshold value, system unload automatically and give an alarm.

(2) Short Circuit Protection and Over Current Protection: when short circuit, fuses in the load bank can insure to unload automatically.

(3) Overheating Protection: temperature is over the safe threshold value, system unload automatically and give an alarm.

(4) Smoke Fog Protection: If there is smoke fog in the container, system cut off load automatically and give an alarm.

(5) Fan Delivery Protection: insufficient air volume with any fan 2450m³/h, system unload automatically and give an alarm.

(6) Overload protection with fan: when any fan cannot normally work, the load bank can unload automatically and give an alarm.

(7) Emergency Stop: manually press the Emergency Stop switch on the panel, then load bank is in locked state, and cannot do any operation.

(8) Protection Switch: some protection with switch, when misinformation or in special need, user can close the corresponding protection function temporarily.

(9) Safety Monitor: through indicator lights on main interface, user can monitor system state. When system abnormally stop and protect, software interface prompt the cause immediately.

Application

Large generator system testing in ocean engineering, drilling facilities,ship construction etc field
Factory testing for generator, static voltage characteristic test, speed characteristic test;
Marine generator overload protection test,parallel operation test,reverse power and reverse current protection test
Assist shipyard in mooring test,sea trial test
Assist with the acceptance of the vessel generator test

3000 KVA 4 Wire 3 Phase Load Bank , Medium Voltage Dry Type AC Load Bank

Send your message to this supplier
Send Now

3000 KVA 4 Wire 3 Phase Load Bank , Medium Voltage Dry Type AC Load Bank

Ask Latest Price
Brand Name :
Kaixiang
Model Number :
AC400-3000KVA
Certification :
ISO9001
Place of Origin :
China
MOQ :
1 set
Price :
negotiable
Contact Supplier
3000 KVA 4 Wire 3 Phase Load Bank , Medium Voltage Dry Type AC Load Bank
3000 KVA 4 Wire 3 Phase Load Bank , Medium Voltage Dry Type AC Load Bank

Hebei Kaixiang Electrical Technology Co., Ltd

Active Member
7 Years
hebei, shijiazhuang
Since 1994
Business Type :
Manufacturer, Exporter, Trading Company, Seller
Total Annual :
10000000-15000000
Employee Number :
120~130
Certification Level :
Active Member
Contact Supplier