400V 1200kW Adjustable Load Bank For Generator With Best Test And Sales
Introduction
Triumph load can simulate the real working conditions and provides a rigorous test regime for power supplies from 1kW to 60MW. Resistive, inductive(reactive),capacitive or combined load banks can be customised for any application. They can be used for testing numerous sets in a workshop environment, or used for on-site commissioning, witness tests and proof trials.
Custom-built load banks can be supplied for most powers, voltages, frequencies and sizes. Multi-voltage load banks are also available for operation over a large voltage range. At the same time, It can operate in parallel with more than two units.
Triumph load are available in stationary type for permanent installation or portable type with fork lift pocket base, castors. Larger load banks, typically above 1200kVA, are based on an ISO container construction. Special finishes including custom paint colors and stainless steel casings can be supplied.
Application
Load banks can be used in a wide variety of applications, such as
1. factory testing of engine generator sets
2. To reducewet stacking problems
3. Periodic excercising of stand-by engine generator sets
4. Ups system testing
5. Battery system testing
6. Ground power testing
7. Load optimization in prime power applications
8. Factory testing of turbines
Technical specification
AC400-1200kW Automatic Load Bank | |
Rating Voltage/Frequency | 400VAC/50Hz, 3 phase 4 wire, line voltage 400V, phase voltage 230V |
Rated Load Power | Resistive load: 1200kW |
Installed Capacity | Resistive load: 1200kW |
Load Step | 1,2,2,5,10,10,20,50,100,200kW*5, total 18 steps, min step load: 1kW for each set of 1200kW load bank. |
PF(Power Factor) | 1 |
Load Tolerance (each step) | ±5% |
Load Tolerance(overall) | ±3% |
Wire Connection |
Load power supply input——Copper bar (star coupling) Control power supply input——Connector-bar |
Insulation | F |
Way of Working | Continuous Working |
Casing Cooling | Forced air cooling,Horizontal inlet air,Vertical cooling |
Operating Environment Parameter | |
Ambient Temperature | -10℃~+50℃ |
Relative Humidity | ≤95% |
Altitude | ≤2500 meter |
Atmospheric Pressure | 86~106kPa |
1. Users can set adjustable discharge power according to capability parameter and test request.
2. Voltage and current value can be displayed with multi-functional digital meter.
3. AC load bank is of all kinds of specifications and series, and include resistance, inductive and capacitive load.
4. Two or more Intelligent AC Load Bank can operate in parallel.
5. It can make stable state test,
6. Remote control by software.
7. Testing data can be saved or transferred by RS485, data can form curve, to be printed.
Why choose kaixiang loadbank?
Variable load with 1kw resolution is provided by totally enclosed fan-cooled tubular stainless steel resistor elements switched by contactors
Designed to operate at 3 phase,50 or 60 hz,with single phase option available.
Transportable loadbanks can be fitted with heavy duty castor wheels or road trailers for greater manoeuvrability