AC400V-250KVA Dummy Load Bank In Good Performance And Resistive Inductive
Introduction
1 AC400V-250KVA Dummy Load Bank can simulate the real working conditions and provides a rigorous test regime for power supplies from 1kW to 60MW. Resistive, inductive(reactive),capacitive or combined load banks can be customised for any application. They can be used for testing numerous sets in a workshop environment, or used for on-site commissioning, witness tests and proof trials.
2 Tailor-made load banks can be supplied for most powers, voltages, frequencies and sizes. Multi-voltage load banks are also available for operation over a large voltage range. At the same time, It can operate in parallel with more than two units.
Application
AC400V-250KVA Dummy Load Bank can be used in a wide variety of applications , such as
Periodic excercising of stand-by engine generator sets
Ups system testing,Battery system testing , Load optimization in prime power applications
Factory testing of turbines , Factory testing of engine generator sets,To reduce wet stacking problems ,
Technical specification
System Parameter | |
Rating voltage/frequency | 400VAC, 3 phase 4 wire 50Hz |
Max Load Power | Apparent Power: 250KVA Resistive Load: 200kW Inductive Load: 150KVAR |
Load Resolution | Resistive Load: 9 steps 1kW,2kW,2kW,5kW,10kW,10kW,20kW,50kW,100kW Inductive Load: 9 steps 1KVAR,2 KVAR, 2KVAR, 5KVAR, 10KVAR, 10KVAR, 20KVAR, 50KVAR,50KVAR |
Power Factor | 0.8(lag) |
Load Tolerance (each step) | ±5% |
Load Tolerance (overall) | ±3% |
Fan &Control Voltage | External AC 3 phase 4 line, 380V/50Hz |
Wire Connection | Load bank input——Copper bar (star coupling ”Y”) Control power input——Connector-bar |
Communication Interface | RS485,RS232 |
Insulation | F |
Duty Cycle | Continuous |
Cooling | Forced air cooling, by Axial Fan; horizontal inlet air, horizontal air outlet |
Transportation | Hoisting, there are lifting lug in top of casing and castor wheel at bottom |
Color | Grey RAL7035 or as required |
Operating Environment Parameter | |
Workplace | Indoor |
Ambient Temperature | -10℃~+50℃ |
Relative Humidity | ≤95% |
Atmospheric Pressure | 86~106kPa |
Brands of Main Components | |
Contactor | Schneider |
Fuse | Miro |
PLC | Siemens |
Alloy Resistor | Kaixiang |
Data Processing Software | Kaixiang |
Overvoltage Protection: the input load voltage is over the safe threshold value, system unload automatically and give an alarm.
Short Circuit Protection and Over Current Protection: when short circuit, fuses in the load bank can insure to unload automatically.
Overheating Protection: temperature is over the safe threshold value, system unload automatically and give an alarm.
Smoke Fog Protection: If there is smoke fog in the container, system cut off load automatically and give an alarm.
Fan Delivery Protection: insufficient air volume with any fan 2450m³/h, system unload automatically and give an alarm.