Portable Electronic 200kw AC Load Bank Single Phase Durable Testing Die Generators
Product Description
This system, which is of independent research and development of electricity load test equipment by our technology, combining dry load module with the automatic measurement and control module, can accurately detect all kinds of generator output power and load capacity, full load and overload test.
Technical Parameters
Rating Voltage/Frequency | 400VAC/50Hz, 3 phase 4 wire, |
Rated Load Power | Resistive load: 200kW |
Installed Capacity | Resistive load: 200kW |
Load Step | 1,2,2,5,10,10,20.50.100kW, min step load: 1kW |
PF(Power Factor) | 1 |
Load Tolerance (each step) | ±5% |
Load Tolerance(overall) | ±3% |
Display Precision | 0.5 class |
Control Power | 220VAC/50Hz, single phase |
Wire Connection | Load power supply input——terminal block |
Insulation | F |
Duty Cycle | Continuous |
Casing Dimensions and Cooling | about 570*530*710mm (length*width*height) Forced air cooling,Horizontal inlet air,Horizontal outlet air |
Weight | About 75kgs/set |
Transportation | Hoisting, there are lifting lug in top of casing |
Casing Color | Grey(RAL7035) |
Ambient Temperature | -10℃~+50℃ |
Relative Humidity | ≤95% |
Altitude | ≤1500 meter |
Atmospheric Pressure | 86~106kPa |
Contactor | Schneider |
Fuse | DELIXI |
MCU | INFINEON |
Data processing software | Kaixiang(self-developed) |
Alloy Resistance | Kaixiang(self-developed) |
Product Advantage
1. Standard Testing Function: The load bank can do stable test, transient test, and realize functions, such as setting, fluctuation, instant load, and instant unload.
2. Super Power Load: high load power density, large capacity of single set, parallel running to finish super power testing, and realize tens of megawatts of power loading.
3. Accurate Data: with high precision data collection module and measuring meter, related equipment has passed the certification by CMA (China Metrology Accreditation) qualification testing institution, and ensure the reliability of data.
4. Flexible Control Mode: based on different using habit, several control mode as following can be choosed, local panel operation, remote box controlling, and intelligent software.
Application
1. Ups system testing
2. Load optimization in prime power applications
3. Factory testing of turbines
4. factory testing of engine generator sets
5. To reducewet stacking problems
6. Periodic excercising of stand-by engine generator sets