250Kw Resistive Resistive Load Bank color Choose For Generator Testing
Product Description
load banks are devices which contain resistive,inductive and/or capacitive loads,apply the load to an electrical power source and dissipate the power of the electrical source .unlike the on-site loads which are randomly variable in terms of many electrical parameters ,load banks provide predetermines and controllable load which serves power source usings energy output to test,support or protect the power source
Technical Parameter
Rating Voltage/Frequency | 415VAC/50Hz, 3 phase 4 wire line phase voltage 240V |
Rated Power | Resistive load:250kW |
Installed Capacity | Resistive load: 250kW |
Load Step | 1,2,2,5,10,10,20,50,50,100kW, min step load: 1kW |
PF(Power Factor) | 1 |
Load Tolerance (each step) | ±5% |
Load Tolerance(overall) | ±3% |
Display Precision | 0.5 class |
Control Power | 3 phase 415VAC 50Hz |
Wire Connection | Load power supply input——Copper bar (star coupling “Y”) Control power supply input——Connector-bar |
Insulation | F |
Way of Working | Continuous Working |
Casing Dimensions and Cooling | about 1600mm×900mm×1500mm (length*width*height) Forced air cooling,Horizontal inlet air and vertical cooling |
Weight | About 600kgs/set |
Transportation | Hoisting, there are lifting lug in top of casing, also the wheel casters can be provided |
Casing Color | Grey(RAL7035)or as you required |
Workplace | Outdoor |
Ambient Temperature | -10℃~+50℃ |
Relative Humidity | ≤95% |
Altitude | ≤2500 meter |
Atmospheric Pressure | 86~106kPa |
Contactor | Schneider |
Fuse | DELIXI |
MCU | INFINEON |
Data processing software | Kaixiang(self-developed) |
Alloy Resistance | Kaixiang(self-developed) |
Product Advangent
1. Prompt delivery & excellent after sales service.
2. Cooperate with many well-known enterprise, offer OEM and ODM service to world famous brands.
3. Certified with China Classification Society (CCS) and ISO9001:2008 Quality Certificate.
Application:
Manufacturers of standby power generators commonly use load banks to test and tune newly assembled units. When the generator has been set up in a test cell within the factory, a test engineer uses the load bank to
apply a discrete, selectable electrical load to the generator and measure the response stability and endurance. During this process, the test engineer calibrates and adjusts the generator performance to ensure it meets the intended product specifications and tolerances.