AC415-5000kW 3 Phase Load Bank With automatic High Performance Grey Container
Product description
AC415-5000kW Automatic Load Bank (hereinafter referred to as "system") and its accessories are proposed including their function, performance, usage, structure, installation and test to provide users with a high efficient and reliable choice, in order to meet the need for generator, UPS load test.
The system consists of 1 sets of 5000kW Resistive load bank. The resistive power is 5000kW. The System is made up of two parts of measurement and control and load, mainly including the outdoor type dry load, automatic data acquisition system, automatically loading and unloading control system, the cooling device, auxiliary control, remote controller and PC software and so on.
Technical Parameter
System Parameter | |
Rating voltage/frequency | 415V 3 phase 4 line,line voltage: 415V, phase voltage: 240V, 50Hz |
Max Load Power | Resistive Load: 5000kW |
Load Resolution | Resistive Load: 33steps, 1kW,2KW,2kW,5kW,10kW,10kW,20kW,50kW,100kW, 200kW,200kW,200kW,200kW,200kW,200KW,200kW,200kW,200kW, 200kW,200kW,200kW,200kW,200kW,200kW,200kW,200kW,200kW, 200kW,200kW,200kW,200kW,200kW,200kW |
Power Factor | 1 |
Load Tolerance (each step) | ±5% |
Load Tolerance (overall) | ±3% |
Fan &Control Voltage | External 415V 3 phase 4 line, line voltage: 415V, phase voltage: 240V, 50Hz |
Wire Connection | Load bank input——Copper bar (star coupling ”Y”) Control power input——Connector-bar |
Communication Interface | RS485,RS232 |
Insulation | F |
Max Protection Grade | IP54 |
Duty Cycle | Continuous |
Cooling | Forced air cooling, by Axial Fan; horizontal inlet air, vertical exhaust cooling |
Enclosure | Container type,with a ladder, air inlet and outlet with mesh enclosure and protection door |
Internal Lighting | Adequate internal lighting will be provided |
Transportation | Hoisting, there are lifting lug in top of casing |
Color | Grey RAL7035 or as required |
Dimensions | About 9150mm*2350mm*2591mm(L×W×H) |
Operating Environment Parameter | |
Ambient Temperature | -10℃~+50℃ |
Relative Humidity | ≤95% |
Atmospheric Pressure | 86~106kPa |
Brands of Main Components | |
Contactor | Schneider |
Fuse | Miro |
PLC | Siemens |
Alloy Resistor | (self-developing) |
Data Processing Software | (self-developing) |
(1) Communication Mode: using photoelectric isolated RS485 communication serial port connect to PC, and with great anti-interference performance to make system control stable. Through converts like USB or RS232 realize communication protocol conversion.
(2) Load Mode: steady-state load (manual load, preset load and automatic load) and transient state load (instant load and instant unload).
(3) Manual Load: input power and power factor, and load according to the preset value.
(4) Preset Load: input generator related parameters, then choose the preset proportion from 0% 25%, 50%, 75%, 100% or other available order and calculate the power value automatically and realize rapid load.
(5) Automatic Load: set several load stages and duration, then complete the process according this stages automatically. Pause at any time or start to next stage in the load process.
Application
Large generator system testing in ocean engineering, drilling facilities,ship construction etc field
Factory testing for generator, static voltage characteristic test, speed characteristic test;
Marine generator overload protection test,parallel operation test,reverse power and reverse current protection test
Assist shipyard in mooring test,sea trial test
Assist with the acceptance of the vessel generator test