Frequency Range: 9 kHz to 9/14/20/26.5/32/43.5/54 GHz
Anritsu’s Field Master Pro MS2090A real time spectrum analyzer delivers performance never previously available in a compact, handheld instrument. With continuous frequency coverage from 9 kHz to 54 GHz, the Field Master Pro MS2090A is specifically designed to meet the test challenges of a full range of other wireless technologies in use today, including: 5G, LTE, wireless backhaul, aerospace/defense, satellite systems, and radar.
The Field Master Pro MS2090A delivers the highest levels of RF performance available in a handheld, touchscreen spectrum analyzer, with a displayed average noise level (DANL) of -164 dBm and Third Order Intercept (TOI) of +20 dBm (typical). This makes measurements such as spectrum clearing, radio alignment, harmonic, and distortion even more accurate than previously possible. For modulation measurements on digital systems, 110 MHz modulation bandwidth coupled with best-in-class phase noise performance maximizes measurement precision, while ±0.5 dB typical amplitude accuracy provides confidence when testing transmitter power and spurious.
Ruggedized for field use, all versions provide a comprehensive range of features to speed and simplify measurement, as well as enhance usability. RTSA spans of 22 MHz to 110 MHz (option dependent) provide capability for cellular interference monitoring to full ISM band signal analysis. In addition to being a full span swept tuned spectrum analyzer, all versions include a spectrogram display that helps monitor the RF spectrum for intermittent or interfering signals. Integrated channel power and occupied bandwidth measurements simplify the measuring and characterizing of common radio transmission. Cable and Antenna line sweep measurements are supported with the addition of the S331P Site Master. IQ data capture of 5G frames enables the capture and saving of IQ data for off-line processing on a PC using standard data analysis tools.
Option |
Description |
MS2090A-0709 |
9 kHz to 9 GHz |
MS2090A-0714 |
9 kHz to 14 GHz |
MS2090A-0720 |
9 kHz to 20 GHz |
MS2090A-0726 |
9 kHz to 26.5 GHz |
MS2090A-0732 |
9 kHz to 32 GHz |
MS2090A-0743 |
9 kHz to 43.5 GHz |
MS2090A-0754 |
9 kHz to 54 GHz |
MS2090A-0003 |
Time Domain Reflectometry (TDR) Measurement (Requires option 331) |
MS2090A-0006 |
Remove Wi-Fi and Bluetooth |
MS2090A-0017 |
Secure Communication |
MS2090A-0019 |
High-Accuracy Power Meter (Requires USB power sensor, sold separately) |
MS2090A-0024* |
Interference Finder (Option 31 and directional antenna recommended, sold separately) |
MS2090A-0027 |
Channel Scanner |
MS2090A-0031* |
GNSS Receiver (Requires GNSS antenna, sold separately) |
MS2090A-0089* |
Zero span IF output |
MS2090A-0090* |
Gated Sweep |
MS2090A-0103* |
55 MHz Analysis Bandwidth |
MS2090A-0104* |
110 MHz Analysis Bandwidth |
MS2090A-0124* |
IQ Waveform Capture (Includes MX280005A IQ Signal Master base feature set) |
MS2090A-0125* |
IQ Waveform Streaming (Includes MX280005A IQ Signal Master base feature set) (Requires option 124) |
MS2090A-0126* |
IQ Waveform Capture (Includes MX280005A IQ Signal Master base feature set) (Non Export Controlled) |
MS2090A-0127* |
IQ Waveform Streaming (Includes MX280005A IQ Signal Master base feature set) (Requires option 126, Non Export Controlled) |
MS2090A-0128* |
Enable Vector Signal Analysis (Requires Option 124 or 126) |
MS2090A-0199* |
Real-Time Spectrum Analysis (RTSA) |
MS2090A-0331* |
Enable S331P Site Master (Requires S331P, sold separately) |
MS2090A-0400* |
Enable Vision Monitor |
MS2090A-0401* |
Enable Vision Locate (Option 400 Required) |
MS2090A-0407* |
Enable High-Speed Port Scanner |
MS2090A-0421* |
Pulse Analyzer |
MS2090A-0431* |
Coverage Mapping (Requires Option 31) |
MS2090A-0444* |
EMF Measurement (Requires Anritsu isotropic antenna, sold separately) |
MS2090A-0445* |
Enable EMF Meter |
MS2090A-0509* |
AM/FM Modulation Measurements |
MS2090A-0871 |
WCDMA FDD Measurements (Requires Option 31) |
MS2090A-0883* |
LTE FDD/TDD Measurements (Requires Option 31) |
MS2090A-0888* |
5G NR Downlink Measurements (Requires Option 31) |
MS2090A-xxxx-097 |
Accredited Calibration to ISO17025 and ANSI/NCSL Z540-1 (xxxx is the frequency option number) |
MS2090A-xxxx-098 |
Standard Calibration to ISO17025 and ANSI/NCSL Z540-1 (xxxx is the frequency option number) |
MS2090A-xxxx-099 |
Premium Calibration to ISO17025 and ANSI/NCSL Z540-1 plus test data (xxxx is the frequency option number) |
Delivering the highest levels of performance available in a handheld RF spectrum analyzer, the Field Master Pro MS2090A instrument gives field engineers and technicians unparalleled measurement accuracy previously reserved for only benchtop instruments.
Interference hunting and spectrum clearing – fast sweep speeds a low distortion front-end and the Real Time spectrum analyzer combine to quickly identify interfering signals. A special interference finder option adds AM/FM demodulation with audio output plus interfering source triangulation on a digital map to pinpoint and identify the location and source of interference.
Broadcast transmitter analysis – a comprehensive range of transmitter measurements – including: AM/FM modulation quality measurements, harmonic, spurious, occupied bandwidth, channel power, and adjacent channel power – ensures conformity to regulatory requirements.
Microwave radio links – with a frequency option up to 54 GHz and exceptional sensitivity for dish alignment, power and modulation bandwidth can be verified during installation or maintenance testing with a waveguide horn antenna.
Satellite system monitoring – ideal for monitoring downlink signals to search for interference and noise
Pulse Radar Measurements - The wide bandwidth of the MS2090A enables detailed analysis of pulsed radar signals. In zero span, resolution bandwidth can be set as high as 40 MHz (option dependent), enabling a sweep time as low as 60 ns and amplitude measurements of pulses as narrow as 20 ns.
LTE base station measurements – OTA or direct connect measurements in single or multi channel configurations
Cell ID, Sector ID, Cell Group
Frequency Error and Time Offset
PBCH, RS, and SS Power
Signal Quality (EVM)
MIMO Antenna Power and Time Alignment Error (TAE)
Channel Power and Occupied Bandwidth
TDD Frame Power
ACLR and Spectral Emissions Masks
Time Alignment Error
Resource Block Usage
OFDM Symbol Transmit Power (OSTP)
Time gated Uplink interference measurements
RSRP based coverage mapping with PCI information
Multi frequency network measurements with carrier aggregation
5GNR base station measurement – validate the performance of the gNB base station with essential measurements that are in full compliance with 3GPP TS 38.104 V15, including:
frequency error
time offset
cell/sector ID
SSB: RSRP, RSRQ, SINR
modulation quality
unwanted emissions
occupied bandwidth
adjacent channel leakage ratio
transmitter harmonics and spurious
EIRP
Time gated Uplink interference measurements
RSRP based coverage mapping with PCI information
Multi frequency network measurements with carrier aggregation
LTE and 5G coverage mapping – receive a clear representation of the signal strength of 5G transmitters over intended geographic area by continuously measuring RF data – including 5G channel power, EIRP, or RSRP – with results graphically displayed on a digital map or building floor plan.
Cable and Antenna measurements – Line sweep RF cables and antennas at base station locations with accessory S331P Site Master
Frequency Range |
MS2090A-0709 9 kHz to 9 GHz |
DANL (w/preamp) |
-164 dBm |
TOI |
+20 dBm |
Analysis bandwidth |
110 MHz |
Demodulation |
5GNR, LTE FDD/TDD, RF, and modulation quality plus SSB signal analysis |
Amplitude range |
DANL to +30 dBm |
Phase noise at 1 GHz |
-110 dBc/Hz @ 100 kHz offset (typical) |
Resolution bandwidth (RBW) |
1 Hz to 10 MHz |
Input SWR |
1.5 |
Amplitude accuracy |
< 14 GHz ±1.3 dB (±0.5 dB typical) |
RTSA bandwidth |
22, 55, 110 MHz (option dependent) |
FAQ:
1.Can you ship order to Canada or Australia ?
Yes,we can .We send orders worldwide .
2. What delivery method do you use ? and delivery time ?
We can ship by EMS,DHL,FedEx,UPS,TNT with tracking number. Usual delivery time is 4-7 workdays.
3. What is your payment term?
100% T/T payment before shipment.
4. How can I ask any other question ?
You can contact us online or leave us messages below .