Fluke 6100A Electrical Power Standard
Description of Fluke 6100A
The most accurate, comprehensive and flexible source of electrical power signals Deregulation of the power industry and the growth of the global power trading market have resulted in a great deal of variability in power quality. Undesirable phenomena such as harmonic distortion, noise and transients, and sags and swells are now common on power supply networks. This in turn is driving the need to make accurate, consistent measurements of power and power quality. Today’s measurement technology is hampered in this effort by a lack of effective, accurate standards to calibrate power measurement instruments. With the release of the 6100A Power Quality Standard, Fluke Precision Measurement provides a highly accurate, scalable system for calibrating power measurement tools to meet the new demands of the global market.
Specifications:
Primary specifications
Voltage/Current amplitude setting resolution: 6 digits
Range of fundamental frequency: 16 Hz to 450 Hz
Frequency accuracy: 50 ppm
Frequency setting resolution: 0.1 Hz
Time to full accuracy: 1 hour
Settling time: < 1.4 second
Nominal angle between voltage phases: 120 º
Nominal angle between voltage and current of a phase: 0 º
Phase angle setting: ± 180 º, ± π radians
Phase angle setting resolution: 0.001 º, 0.00001 radians
Harmonics
Number of harmonics available: 100 (simultaneously if required)
Maximum harmonic frequency available: 6 kHz (100th Harmonic of 60 Hz)
Maximum level of individual harmonic: 30 % of fundamental level
Setting Method (user selectable): % RMS, % fundamental, dB down from fundamental, absolute value
Flicker
Setting range: ±30 % of set voltage or current within range values (60 % ∆V/V)
Flicker modulation depth accuracy: 0.025 %
Modulation depth setting resolution: 0.001 %
Shape: Rectangular or Sinusoidal
Duty cycle (shape = rectangular): 0.1 % to 99.9 % ±31 µs
Modulating Frequency range: 0.0008 Hz to 40 Hz
Pst Indication accuracy: 0.25 % Valid for Voltage only between 220 V and 240 V
Fluctuating Harmonics
Number of harmonics to fluctuate: Any number from 0 to all set harmonics can fluctuate
Setting range: ±30 % of nominal harmonic voltage
Fluctuation accuracy: 0.025 %
Modulation depth setting resolution: 0.001 %
Shape: Rectangular or Sinusoidal
Duty cycle (shape = rectangular): 0.1 % to 99.9 % ±31 µs
Modulating Frequency range: 0.008 Hz to 30 Hz
Power
Voltage: 100 V to 240 V with up to 10 % fluctuations
Transient overvoltages: Impulse withstand (overvoltage) category II of IEC 60364-4-443
Frequency: 47 Hz to 63 Hz
Max. consumption: 1000 VA 100 V – 130 V, 1250 VA 130 V – 240 V
Dimensions
Height: 233 mm (9.17 inches)
Width: 432 mm (17 inches)
Depth: 630 mm (24.8 inches)
Weight: 23 kg (51 lbs)
Who needs a 6100A?
Validation of electrical power measurements and the equipment that make them is required in many disciplines: • In design engineering to guarantee that measurements are being made correctly and accurately • In manufacturing test to make certain that measurements are correct and repeatable on every unit manufactured • In service and calibration to ensure that instruments continue to perform to specification throughout their lifetime • In standards laboratories to ensure measurement techniques and equipment meet appropriate standards. The Fluke 6100A provides the tools, the functions and the performance to fulfill these requirements comprehensively, accurately and reliably.
Ordering information
Model
6100A Electrical Power Standard Master comprises:
• One phase, (one voltage channel to 1000 V, one current channel to 21 A)
• User controls and display system
• Interfacing via GPIB/RS232
• Interfacing to Auxiliary Unit
• Line cord
• Lead kit
• User manual
6101A Auxiliary Power Standard comprises:
• One phase, (one voltage channel to 1000 V, one current channel to 21 A)
• Cable and interfacing to connect to Master
• Line cord
• Lead kit 6100A/80A Electrical Power Standard Master comprises:
• One phase, (one voltage channel to 1000 V, one current channel to 80 A)
• User controls and display system
• Interfacing via GPIB/RS232
• Interfacing to Auxiliary Unit
• Line cord
• Lead kit
• User manual 6101A/80A Auxiliary Power Standard comprises:
• One phase, (one voltage channel to 1000 V, one current channel to 80 A)
• Cable and interfacing to connect to Master
• Line cord
• Lead kit 6100A/E Electrical Power Standard Master comprises:
• One phase, (one voltage channel to 1000 V, one current channel to 21 A) with energy counting option fitted
• User controls and display system
• Interfacing via GPIB/RS232
• Interfacing to Auxiliary Unit
• Line cord
• Lead kit
• User manual 6100A/E/80A Electrical Power Standard comprises:
• One phase, (one voltage channel to 1000 V, one current channel to 80 A) with energy counting option fitted
• Cable and interfacing to connect to Master
• Line cord
• Lead kit
• User manual
FAQ:
1.Can you ship order to Canada or Australia ?
Yes,we can .We send orders worldwide .
2. What delivery method do you use ? and delivery time ?
We can ship by EMS,DHL,FedEx,UPS,TNT with tracking number. Usual delivery time is 4-7 workdays.
3. What is your payment term?
100% T/T payment before shipment.
4. How can I ask any other question ?
You can contact us online or leave us messages below .