Specifications
Brand Name :
Rohde & Schwarz
Model Number :
ZVH
Certification :
ISO17025
Place of Origin :
Germany
MOQ :
1 set
Price :
Negotiable
Payment Terms :
T/T,Western Union
Supply Ability :
In Stock
Delivery Time :
1~3 Working Days
Packaging Details :
Carton
Frequency range :
100 kHz to 3.6 GHz
Output power :
0 dBm to –40 dBm (nominal), in 1 dB steps
Maximum permissible spurious signal level :
+17 dBm (nominal)
Display :
6.5" color LCD with VGA resolution
Battery operating time :
up to 3h
Weight :
< 3 kg (6.6 lb)
Description
Rohde & Schwarz ZVH4 Portable Cable Analyzer Antenna Analyzer 2.0 Port N-Type Connector ZVH4
KEY FACTS OF Rohde & Schwarz ZVH4 Portable Cable Analyzer
► Frequency range from 100 kHz to 3.6 GHz or 8 GHz
► 100 dB (typ.) dynamic range for filter and antenna isolation measurements
► Factory calibration over entire frequency range
► Built-in DC voltage supply (bias) for active components such as amplifiers
► Power meter option
► Saving of measurement results on SD memory card or USB memory stick
► Easy operation with user-configurable test sequences (wizard)
► Easy-to-replace Lithium-ion battery for up to 4.5 h of operation
► Rugged, splash-proof housing for rough work in the field
► Easy handling due to low weight (3 kg with battery) and easy-to-reach function keys
BENEFITS AND KEY FEATURES OF Rohde & Schwarz ZVH4 Portable Cable Analyzer
Installation of antenna systems
► Distance-to-fault measurements (DTF)
► One-port cable loss measurements
► Reflection measurement
► Transmission measurements
► Built-in DC voltage supply
► Position finding using GPS receiver
► Factory calibration of the R&S®ZVH
Rohde & Schwarz ZVH4 Portable Cable Analyzer Antenna Analyzer 2.0 Port N-Type Connector ZVH4
Rohde & Schwarz ZVH4 Portable Cable Analyzer Antenna Analyzer 2.0 Port N-Type Connector ZVH4

Maintenance of antenna systems

► Two-port vector network analysis
► Vector voltmeter
► Terminating and directional power measurements
► Pulse analysis with wideband power sensors
► Internal channel power meter
► Spectrum analysis measurements
► Spectrogram measurements
Rohde & Schwarz ZVH4 Portable Cable Analyzer Antenna Analyzer 2.0 Port N-Type Connector ZVH4
Rohde & Schwarz ZVH4 Portable Cable Analyzer Antenna Analyzer 2.0 Port N-Type Connector ZVH4

Easy operation

► Test report in just a few steps using the
R&S®ZVH wizard
► Channel tables for frequency setting
► Optimal reading of measurement results in any situation
► Operation in different languages
► Easy-to-access, well-protected connectors
Rohde & Schwarz ZVH4 Portable Cable Analyzer Antenna Analyzer 2.0 Port N-Type Connector ZVH4
Rohde & Schwarz ZVH4 Portable Cable Analyzer Antenna Analyzer 2.0 Port N-Type Connector ZVH4
Rohde & Schwarz ZVH4 Portable Cable Analyzer Antenna Analyzer 2.0 Port N-Type Connector ZVH4
Rohde & Schwarz ZVH4 Portable Cable Analyzer Antenna Analyzer 2.0 Port N-Type Connector ZVH4

Documentation and remote control

► R&S®InstrumentView software for documenting
measurement results
► Remote control via LAN or USB
Rohde & Schwarz ZVH4 Portable Cable Analyzer Antenna Analyzer 2.0 Port N-Type Connector ZVH4

Specifications of Rohde & Schwarz ZVH4 Portable Cable Analyzer

Frequency

Frequency range R&S®ZVH4 100kHzto3.6GHz
R&S®ZVH8 100kHzto8GHz
Frequency resolution 1Hz
Reference frequency, Internal
Total reference accuracy ± (time since last adjustment × aging rate)
+ temperature drift + calibration accuracy
Aging per year ±1 × 10-6
Temperature drift 0 °C to + 50 °C ¹ ±1 × 10-6
Achievable initial calibration accuracy ±5 × 10-7
Reference frequency, with R&S®HA-Z240 GPS receiver option
Frequency accuracy GPS on, ≥ 1 min after satellite lock ±2.5 × 10–8
up to 30 min after losing satellite lock ±5 × 10–8
Reference frequency, with R&S®FSH-Z114 precision frequency reference option
Aging per year 3.6 × 10–9
Temperature drift 0 °C to + 50 °C 4 × 10–10
Achievable initial calibration accuracy 1 × 10–9
Total reference uncertainty R&S®FSH-Z114 connected
≥ 30 s after oscillator lock (time since last adjustment × aging rate) + temperature drift + 3 × calibration accuracy (nominal)
≥ 2 min after oscillator lock (time since last adjustment × aging rate) + temperature drift + calibration accuracy
Frequency readout
Marker resolution 0.1Hz
Accuracy ± (marker frequency × reference accuracy) + 10% × measurement bandwidth + ½((fstop–fstart) / (data points – 1) + 1 Hz)

Measurement

Individual measurements reflection (S11, S22)
with R&S®ZVH-K39 option transmission (S21,S12)
one-port cable loss
distance-to-fault
Measurement Wizard
Guides the user through a sequence of individual measurements, uses the R&S®InstrumentView PC software to configure the measurement sequence including hints displayed on the screen;
R&S®InstrumentView is also used to combine the measurement results into user-configurable reports.

Measurement set up
Port output power controlled via tracking generator attenuation 0 dBm to – 40 dBm (nom.), in 1dB steps
Receive path RF attenuation 0 dB to 30 dB in 5 dB steps
Data points selectable 101, 201, 401, 601, 631, 801, 1001, 1201
Measurement bandwidth range 100 Hz to 100 kHz in 1/3 sequence
Trace modes clear/write average, interference
suppression
DC bias
DC source selectable internal or external
Output port selectable port 1 or 2
Output voltage mode: internal +12 V to + 32 V in 1 V steps
Maximum output power mode: internal
operatedwithbattery 4 W
operatedwithACmains 10 W
Maximumcontinuousoutputcurrent mode: internal 500 mA
Trigger
Trigger source free run, external rise, external fall
External trigger level TTL level

Reflectionmeasurement S11, S22
Result formats magnitude,VSWR
Magnitude
Range 1/2/5/10/20/50/100/120/150 dB, linear 100%
Resolution 0.01dB
VSWR
Range selectable 1 to 1.5, 2, 6, 11, 21 or 71
Corrected directivity 100 kHz ≤ f ≤ 3 GHz > 43dB (nom.)
3 GHz < f ≤ 6 GHz > 37dB (nom.)
6 GHz < f ≤ 8 GHz > 31dB (nom.)
Corrected test port match 100 kHz ≤ f ≤ 3 GHz > 40dB (nom.)
3 GHz < f ≤ 6 GHz > 37dB (nom.)
6 GHz < f ≤ 8 GHz > 30dB (nom.)
Measurement uncertainty see figure “Uncertainty of reflection measurement” on page7

Transmission measurement S21, S12 (withR&S®ZVH-K39 option)
Result format magnitude
Measurement range –120dBto+80dB
Display range selectable 1/2/5/10/20/50/100/120/150dB,
linear100%
Resolution 0.01dB
Dynamic range RF attenuation = 5dB, tracking generator level = –10 dBm, RBW = 1 kHz
100 kHz ≤ f < 300 kHz > 50 dB (nom.)
300 kHz ≤ f < 2.5 GHz > 80 dB,100 dB (typ.)
2.5 GHz ≤ f < 6 GHz > 70 dB, 90 dB (typ.)
6 GHz ≤ f < 8 GHz > 50 dB (nom.)
Test port match as specified for test port input/output
Measurement uncertainty calibration method = full two port high accuracy see figure “Transmission magnitude uncertainty” on page 7

One-port cable loss measurement
Result format magnitude
Range selectable 1/2/5/10/20/50/100/120/150 dB
Resolution 0.01dB

Distance-to-fault analysis
Result formats return loss, VSWR (average and maximum indication)
Return loss
Range 1/2/5/10/20/50/100/120/150dB, linear100%
Resolution 0.01dB
VSWR
Range selectable 1to1.5,2,6,11,21or71
Fault resolution in meters (1.5 × 108 × velocity factor/span)
Maximum cable length depending on cable loss 1500 m (nom.)

Immunity to interference
Maximum permissible spurious signal measurement = reflection (S11)/one-port cable loss/distance-to-fault analysis
RF attenuation = 5 dB +10 dBm (nom.)
RF attenuation = 30 dB +17 dBm (nom.)


FAQ:

1. Can you ship the order to Canada or Australia?

Yes, we can. We send orders worldwide.

2. What delivery method and delivery time do you use?

We can ship by EMS, DHL, FedEx, UPS, and TNT with tracking numbers. The usual delivery time is 4-7 workdays.

3. What is your payment term?

100% T/T payment before shipment.

4. How can I ask any other question?

You can contact us online or leave us messages below.

Rohde & Schwarz ZVH4 Portable Cable Analyzer Antenna Analyzer 2.0 Port N-Type Connector ZVH4

Rohde & Schwarz ZVH4 Portable Cable Analyzer Antenna Analyzer 2.0 Port N-Type Connector ZVH4

Rohde & Schwarz ZVH4 Portable Cable Analyzer Antenna Analyzer 2.0 Port N-Type Connector ZVH4

Rohde & Schwarz ZVH4 Portable Cable Analyzer Antenna Analyzer 2.0 Port N-Type Connector ZVH4

Rohde & Schwarz ZVH4 Portable Cable Analyzer Antenna Analyzer 2.0 Port N-Type Connector ZVH4

Rohde & Schwarz ZVH4 Portable Cable Analyzer Antenna Analyzer 2.0 Port N-Type Connector ZVH4

Rohde & Schwarz ZVH4 Portable Cable Analyzer Antenna Analyzer 2.0 Port N-Type Connector ZVH4

Send your message to this supplier
Send Now

Rohde & Schwarz ZVH4 Portable Cable Analyzer Antenna Analyzer 2.0 Port N-Type Connector ZVH4

Ask Latest Price
Brand Name :
Rohde & Schwarz
Model Number :
ZVH
Certification :
ISO17025
Place of Origin :
Germany
MOQ :
1 set
Price :
Negotiable
Contact Supplier
Rohde & Schwarz ZVH4 Portable Cable Analyzer Antenna Analyzer 2.0 Port N-Type Connector ZVH4
Rohde & Schwarz ZVH4 Portable Cable Analyzer Antenna Analyzer 2.0 Port N-Type Connector ZVH4
Rohde & Schwarz ZVH4 Portable Cable Analyzer Antenna Analyzer 2.0 Port N-Type Connector ZVH4
Rohde & Schwarz ZVH4 Portable Cable Analyzer Antenna Analyzer 2.0 Port N-Type Connector ZVH4
Rohde & Schwarz ZVH4 Portable Cable Analyzer Antenna Analyzer 2.0 Port N-Type Connector ZVH4
Rohde & Schwarz ZVH4 Portable Cable Analyzer Antenna Analyzer 2.0 Port N-Type Connector ZVH4

Shenzhen Meigaolan Electronic Instrument Co. Ltd

Verified Supplier
3 Years
shenzhen
Since 2003
Business Type :
Distributor/Wholesaler
Total Annual :
500000-1000000
Employee Number :
>100
Certification Level :
Verified Supplier

Find Similar Products By Category:

Contact Supplier
Submit Requirement