Maximum Frequency: 53 GHz
Minimum Frequency: 9 kHz / 100 kHz
SA Start Frequency: 9 kHz / 100 kHz
System Dynamic Range: > 140 dB
Output Power: 10 dBm
Trace Noise: 0.0015 dBrms (10 kHz IFBW)
Number of Built-In Ports: 2 or 4 ports (2nd source (optional) on 4-ports)
Harmonics: -25 dBc (Typical)
Best Speed at 201 Point, 1 Sweep: 1.6 msec
Instrument Type: Benchtop
Applications:
Components:
System Features:
DANL @1 GHz: -150 dBm/Hz (Typical)
Phase Noise @1 GHz (1 MHz offset): -128 dBc/Hz (Typical)
Phase Noise @1 GHz (10 kHz offset): -103 dBc/Hz (Typical)
TOI @1 GHz (3rd Order Intercept): +22 dBm
Benchtop: Yes
Temperature Stability: 0.005 dB/ ⁰C (Typical)
Weight: 14 kg (2-port), 15 kg (4-port)
021 | Add pulse modulator to internal 1st source |
022 | Add pulse modulator to internal 2nd source |
090 | Spectrum analysis hardware, 9 kHz to 4.5 GHz |
091 | Spectrum analysis hardware, 9 kHz to 6.5 GHz |
092 | Spectrum analysis hardware, 9 kHz to 9 GHz |
093 | Spectrum analysis hardware, 9 kHz to 14 GHz |
094 | Spectrum analysis hardware, 9 kHz to 20 GHz |
095 | Spectrum analysis hardware, 100 kHz to 26.5 GHz |
096 | Spectrum analysis hardware, 100 kHz to 32 GHz |
097 | Spectrum analysis hardware, 100 kHz to 44 GHz |
098 | Spectrum analysis hardware, 100 kHz to 53 GHz |
120 | Add internal bias tees for 2-port E5080B up to 20 GHz |
140 | Add internal bias tees for 4-port E5080B up to 20 GHz |
172 | Add GPIB interface |
175 | Add analog input and output |
1A7 | Calibration + Uncertainties + Guardbanding |
1E5 | Add high stability timebase |
1NC | Equipped with type-N connectors |
240 | 2-port test set, 9 kHz to 4.5 GHz |
260 | 2-port test set, 9 kHz to 6.5 GHz |
290 | 2-port test set, 9 kHz to 9 GHz |
2D0 | 2-port test set, 9 kHz to 14 GHz |
2H0 | 2-port test set, 9 kHz to 18 GHz |
2K0 | 2-port test set, 9 kHz to 20 GHz |
2L0 | 2-port test set, 100 kHz to 26.5 GHz |
2M0 | 2-port test set, 100 kHz to 32 GHz |
2N0 | 2-port test set, 100 kHz to 44 GHz |
2P0 | 2-port test set, 100 kHz to 53 GHz |
440 | 4-port test set, 9 kHz to 4.5 GHz |
442 | 4-port test set, 9 kHz to 4.5 GHz with second source |
460 | 4-port test set, 9 kHz to 6.5 GHz |
462 | 4-port test set, 9 kHz to 6.5 GHz with second source |
490 | 4-port test set, 9 kHz to 9 GHz |
492 | 4-port test set, 9 kHz to 9 GHz with second source |
4D0 | 4-port test set, 9 kHz to 14 GHz |
4D2 | 4-port test set, 9 kHz to 14 GHz with second source |
4H0 | 4-port test set, 9 kHz to 18 GHz |
4H2 | 4-port test set, 9 kHz to 18 GHz with second source |
4K0 | 4-port test set, 9 kHz to 20 GHz with second source |
4K2 | 4-port test set, 9 kHz to 20 GHz with second source |
4L0 | 4-port test set, 100 kHz to 26.5 GHz |
4L2 | 4-port test set, 100 kHz to 26.5 GHz with second source |
4M0 | 4-port test set, 100 kHz to 32 GHz |
4M2 | 4-port test set, 100 kHz to 32 GHz with second source |
4N0 | 4-port test set, 100 kHz to 44 GHz |
4N2 | 4-port test set, 100 kHz to 44 GHz with second source |
4P0 | 4-port test set, 100 kHz to 53 GHz |
4P2 | 4-port test set, 100 kHz to 53 GHz with second source |
A6J | ANSI Z540-1-1994 Calibration |
S96007A | Automatic Fixture Removal |
S96007B | Automatic Fixture Removal |
S96010A | Time Domain Analysis |
S96010B | Time Domain Analysis |
S96011A | Enhanced Time Domain Analysis with TDR |
S96011B | Enhanced Time Domain Analysis with TDR |
S96025A | Basic Pulsed-RF Measurements |
S96025B | Basic Pulsed-RF Measurements |
S96029A | Noise Figure Measurements with Vector Correction |
S96029B | Noise Figure Measurements with Vector Correction |
S96082A | Scalar Mixer/Converter Measurements |
S96082B | Scalar Mixer/Converter Measurements |
S96083A | Vector and Scalar Mixer/Converter Measurements |
S96083B | Vector and Scalar Mixer/Converter Measurements |
S96084A | Embedded LO Capability |
S96084B | Embedded LO Capability |
S96086A | Gain-Compression Measurements |
S96086B | Gain-Compression Measurements |
S96089B | Differential and I/Q Device Measurements |
S96090A | Spectrum Analysis |
S96090B | Spectrum Analysis |
S96552B | Multiport Calibration Assistant |
U8487A | 10 MHz – 50 GHz USB Thermocouple Power Sensor |
WIN10 |
FAQ:
1.Can you ship order to Canada or Australia ?
Yes,we can .We send orders worldwide .
2. What delivery method do you use ? and delivery time ?
We can ship by EMS,DHL,FedEx,UPS,TNT with tracking number. Usual delivery time is 4-7 workdays.
3. What is your payment term?
100% T/T payment before shipment.
4. How can I ask any other question ?
You can contact us online or leave us messages below.