Key facts of R&S®RTM3000 Oscilloscope
R&S®RTC1000 | R&S®RTB2000 | R&S®RTM3000 | R&S®RTA4000 | |
Number of oscilloscope channels | 2 | 2/4 | 2/4 | 4 |
Bandwidth in MHz | 50, 70, 100, 200, 300 | 70, 100, 200, 300 | 100, 200, 350, 500, 1000 | 200, 350, 500, 1000 |
Maximum sampling rate in Gsample/s | 1/channel, 2 interleaved | 1.25/channel, 2.5 interleaved | 2.5/channel, 5 interleaved | 2.5/channel, 5 interleaved |
Maximum memory depth in Msample | 1/channel, 2 interleaved | 10/channel, 20 interleaved; 160 Msample (optional) segmented memory | 40/channel, 80 interleaved; 400 Msample (optional) segmented memory | 100/channel, 200 interleaved; 1 Gsample (standard) segmented memory |
Timebase accuracy in ppm | 50 | 2.5 | 2.5 | 0.5 |
Vertical bits (ADC) | 8 | 10 | 10 | 10 |
Minimum input sensitivity | 1 mV/div | 1 mV/div | 500 µV/div | 500 µV/div |
Display | 6.5", 640 × 480 pixel | 10" capacitive touch, 1280 × 800 pixel | 10" capacitive touch, 1280 × 800 pixel | 10" capacitive touch, 1280 × 800 pixel |
Update rate | 10000 waveforms/s | 300000 waveforms/s in fast segmentated memory mode | 2000000 waveforms/s in fast segmentated memory mode | 2000000 waveforms/s in fast segmentated memory mode |
MSO | 8 channels, 1 Gsample/s | 16 channels, 2.5 Gsample/s | 16 channels, 5 Gsample/s | 16 channels, 5 Gsample/s |
Protocol (optional) | I 2 C, SPI, UART/RS-232/ RS-422/RS-485, CAN, LIN | I2C, SPI, UART/RS-232/ RS-422/RS-485, CAN, LIN | I2C, SPI, UART/RS-232/RS-422/ RS-485, CAN, LIN, audio (I²S/ LJ/RJ/TDM), ARINC, MIL | I2C, SPI, UART/RS-232/ RS-422/RS-485, CAN, LIN, audio (I²S), ARINC, MIL |
Generator(s) | 1 generator, 4-bit pattern generator | 1 ARB, 4-bit pattern generator | 1 ARB, 4-bit pattern generator | 1 ARB, 4-bit pattern generator |
Math | +,–, *,/,FFT(128k points) | ) +,–, *,/,FFT(128k points) | +,–, *,/,FFT(128k points), 21 advanced functions | +,–, *,/,FFT(128k points), 21 advanced functions |
Rohde&Schwarz probe interface | - | - | standard | standard |
RF capability | FFT | FFT | spectrum analysis | spectrum analysis |
Benefits of R&S®RTM3000 Oscilloscope
SEE SMALL SIGNAL DETAILS IN THE PRESENCE OF LARGE SIGNALS
Specifications in brief | ||
Vertical system | ||
Number of channels | R&S®RTM3002; R&S®RTM3004 | 2; 4 |
Bandwidth (–3 dB) at 50 Ω | R&S®RTM3002/3004 (with R&S®RTM-B2x2/-B2x3/-B2x5/-B2x10 options) | 100 MHz, 200 MHz, 350 MHz, 500 MHz, 1 GHz |
Rise time (calculated) | R&S®RTM3002/3004 (with R&S®RTM-B2x2/-B2x3/-B2x5/-B2x10 options) | 3.5 ns, 1.75 ns, 1 ns, 700 ps, 350 ps |
Input impedance | 50 Ω ± 1.5% (meas.), 1 MΩ ± 1% (meas.) || 14 pF ± 1 pF (meas.) | |
Input sensitivity | max. bandwidth in all ranges | |
at 1 MΩ | 500 µV/div to 10 V/div | |
at 50 Ω | 500 µV/div to 1 V/div | |
DC gain accuracy | offset and position = 0, maximum operating temperature change of ±5°C after self-alignment | |
input sensitivity > 5 mV/div | ±1.5% of full scale | |
input sensitivity ≤ 5 mV/div | ±2% of full scale | |
ADC resolution | 10 bit, up to 16 bit with high resolution decimation | |
Acquisition system | ||
Maximum realtime sampling rate | 2.5 Gsample/s; 5 Gsample/s, interleaved | |
Acquisition memory | standard; with R&S®RTM-K15 option | 40 Msample (80 Msample interleaved); 400 Msample segmented memory |
Horizontal system | ||
Timebase range | selectable between 0.5 ns/div and 500 s/div | |
Trigger system | ||
Trigger types | standard | edge, width, video (PAL, NTSC, SECAM, PAL-M, SDTV 576i, HDTV 720p, HDTV 1080i, HDTV 1080p), pattern, line, serial bus, timeout |
option | I2C, SPI, UART/RS-232/RS-422/RS-485, CAN/LIN, ARINC429, MIL-STD-1553 | |
MSO option | ||
Digital channels | 16 (2 logic probes) | |
Sampling rate | 1.25 Gsample/s | |
Acquisition memory | standard; with R&S®RTM-K15 option | 40 Msample (80 Msample interleaved); 400 Msample segmented memory |
Waveform generator | ||
Resolution, sample rate | 14 bit, 250 Msample/s | |
Amplitude | high Z; 50 Ω | 20 mV to 5 V (Vpp); 10 mV to 2.5 V (Vpp) |
DC offset | high Z; 50 Ω | ±5 V; ±2.5 V |
Signal forms frequency ranges | sine | 0.1 Hz to 25 MHz |
pulse/rectangle | 0.1 Hz to 10 MHz | |
ramp/triangle | 0.1 Hz to 1 MHz | |
noise | max. 25 MHz | |
Arbitrary | sampling rate; memory depth | max. 10 Msample/s; 32k points |
General data | ||
Screen | 10.1" WXGA TFT color display (1280 × 800 pixel) | |
Interfaces | USB host with MTP, USB device, LAN, powerful web server for remote display and operation | |
Audible noise | 28.3 dB(A) | |
Dimensions | 390 mm × 220 mm × 152 mm (15.4 in × 8.66 in × 5.98 in) | |
Weight | 3.3 kg (7.27 lb) |
FAQ:
Q: What delivery methods do you use, and what is the delivery time?
A: We ship via EMS, DHL, FedEx, UPS, and TNT with tracking numbers. Delivery typically takes 4-7 business days.
Q: How are duties and taxes handled?
A: Duties and taxes vary by country and are usually the buyer’s responsibility. Please check local import regulations for details.
Q: What are your payment terms?
A: We require 100% T/T payment before shipment.
Q: How can I ensure the quality of products purchased internationally?
A: We work with reputable suppliers and conduct thorough inspections before shipping. Warranties are available for most products—please check for specific terms.
Q: What should I do if my shipment is delayed?
A: Check the tracking information provided. If there are delays, contact us or the carrier directly for updates.
Q: Do you offer discounts for bulk orders?
A: Yes, discounts may be available for bulk purchases. Please contact us to discuss your specific requirements.