YH-1013 Two Cases Of Cold And Hot Shock
USE:
1.The two cases of thermal shock test box are mainly used in the fields of electronics,aviation, automobile, metal, military,LED, circuit board, scientific research, etc. , the degree to which the specimen can be subjected to both extremely high and extremely low temperatures in a short period of time to detect chemical reaction or physical damage caused by thermal expansion and contraction of the specimen.The instrument is divided into three parts: Cold Storage Chamber,Heat Storage Chamber and test chamber.The tested products are put in the test chamber at rest.
Freature:
1.Use Color Chinese and English 10-inch LCD touch-control graphic interface,easy to operate.
2.The equipment is divided into three parts: high-temperature zone, low-temperature zone and test zone.
3.The impact way uses the air way to switch the way to lead the temperature into the test area, makes the hot and cold impact test.
4.The maximum time and cycle period can reach 9999 minutes and 9999 times during high or low temperature shock.The system can be operated as automatic cycle shock or manual selective shock and can be set to 2 zone, or 3 zone shock and cold and hot shock start.
5.cooling adopt binary freezing system, cooling effect is fast, cooling mode is air-cooled or water-cooled two kinds.
Parameter:
Model | YHS-60(A~C) | YHS-80(A~C) | YHS-150(A~C) | YHS-252(A~C) | YHS-450(A ~c) |
Internal size W*H*D(cm) | 50x 400 x 30 | 50x40x 40 | 60x50x50 | 70x60x60 | 80x75x75 |
External size W*H*D(cm) | 145× 180 x 145 | 148× 190 x 155 | 160x 200 x 175 | 175×210x 187 | 190 x220 x 200 |
Temperature range(test area) | 150℃ ~A:-45℃;B:-55℃; C:-65℃; High temperature zone: 60℃~150℃; Low temperature zone-10 ℃~65℃ | ||||
Heating up time (heat storage zone) | RT~200℃ 35min RT ~ 200℃takes about 35 min | ||||
Cooling time (cool storage area) | RT~-70℃ 85min RT ~-70℃takes about 85 min | ||||
The temperature response time /conversion time | ≤5 minl≤10 sec | ||||
Temperature control accuracy/distribution accuracy | +0.5℃/ ±2.0℃ | ||||
lnsulation material | High temperature resistant and high density exothermic material of ethyl chloroformate foam | ||||
System | P.l.D+S.S.R. microcomputer balanced temperature control system | ||||
Cooling system | Semi-closed double-stage compressor (water-cooled)/ful-closed double-stage compressor (air-cooled) | ||||
Safety device | High and low voltage protection swiches for Circuit breaker and compressors,high volage protection swtiches for refigerants, fault warning systems electronic alams | ||||
Accessories | Viewing window (special purchase Type) , up and down adjustable interayer two pieces,electrified test hole, caster, horizontal bracket | ||||
Power supply | AC380V 50Hz/60Hz 3 | ||||
weight(approx.) | 700kg | 900kg | 1200kg | 1400kg | 1900kg |