Blockchain Miners Liquid Submersion Cooling System Dry Cooling Tower
What's Immersion Cooling?
Also known as liquid submersion cooling. It is the practice of submerging computer components (or full servers) in a thermally, but not electrically, conductive liquid (dielectric coolant) allowing higher heat transfer performance than air and many other benefits.
Why many large data centers have already moved or are considering the move to immersion cooling?
1. Save floor space. Compare with traditional forced air cooling way(using precision air conditioner), immersion cooling system will save much floor space. Because no need rack system and no need air conditioner indoor.
2. Save power. Compare with traditional forced air cooling way(using precision air conditioner), immersion cooling system will save much power. For example, no need to install many air conditioners indoor, then no compressor power consumption. For example, the bitcoin miners no need air cooling fans. Thesewill save power around 18~25%.
3. Increase hardware lifepan. In immersion, machines operate in a 100% controlled environment with no dust, no temperature of humidity fluctuations, no impurities. This will extend the service life of the mining machine or server. This will also reduce machine maintainance fee.
4. Increase hashrate of the mining machine.
For bitcoin mining farm, if use immersion cooling system, our dry cooler is the most cost-effective way to remove heat and a necessary component of the immersion cooling system, We designed a full range of immersion optimized dry coolers. From 5kW single fan unit to the V-shaped 48-921kW dry coolers. Made in China, sized to your needs.
Also, we have whole immersion cooling system clients, they can also offer the whole system proposal for you.
Features
Dry coolers use ambient air to cool process fluids. Multiple units can be employed to handle even greater heat loads. Configuration choices include horizontal or vertical air discharge, single or double row fans, and vertical, horizontal or V mounted coils. Units can have multiple circuits, multiple passes and can be configured to be piped in series or parallel. The rugged, weather-proof design is manufactured with corrosion-resistant galvanized steel sheet, finished with high quality polyurethane paint. Standard cooling coils consist of copper tubes and aluminum fins, which are coupled with high efficiency, low noise fans. A variety of optional fan controls can be provided, including step controls and variable speed drives in single- and three-phase voltages to match your electric power supply.
Technical parameter
Dry cooling tower D2 series parameter(fin space 2.1mm)
Type | D2-148- 4x630 | D2-166- 4x630 | D2-175- 4x630 | D2-228- 6x630 | D2-250- 6x630 | D2-276- 6x630 | D2-310- 8x630 | D2-343- 8x630 | D2-364- 8x630 | D2-392- 10x630 | |||
Capacity | Water | KW | 147.99 | 165.85 | 175.21 | 227.85 | 250.42 | 276.53 | 309.85 | 342.73 | 364.07 | 391.99 | |
20% Et. Glycol | KW | 142.42 | 161.57 | 170.91 | 219.09 | 244.69 | 270.22 | 301.18 | 333.55 | 354.64 | 383.3 | ||
Air flow | M3/h | 76459 | 74341 | 72134 | 114686 | 111511 | 108188 | 152911 | 148675 | 144255 | 191136 | ||
Fan | No. X φ | 2x2x630 | 2x2x630 | 2x2x630 | 2x3x630 | 2x3x630 | 2x3x630 | 2x4x630 | 2x4x630 | 2x4x630 | 2x5x630 | ||
Fan motor | A | 20.4 | 20.4 | 20.4 | 30.6 | 30.6 | 30.6 | 40.8 | 40.8 | 40.8 | 51 | ||
400/3N/50HZ | |||||||||||||
Sound pressure level | dB(A)10m | 64 | 64 | 64 | 66 | 66 | 66 | 67 | 67 | 67 | 68 | ||
Dimension | L | mm | 2186 | 2186 | 2186 | 3250 | 3250 | 3250 | 4250 | 4250 | 4250 | 5250 | |
H | mm | 1874 | 1874 | 1874 | 1874 | 1874 | 1874 | 1874 | 1874 | 1874 | 1874 | ||
D | mm | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 | ||
D1 | mm | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | ||
L1 | mm | 963 | 963 | 963 | 963 | 963 | 963 | 963 | 963 | 963 | 963 | ||
L2 | mm | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | ||
L3 | mm | 1963 | 1963 | 1963 | 2963 | 2963 | 2963 | 3963 | 3963 | 3963 | 4963 | ||
Connections inlet φ | mm | 2XDN50 | 2XDN65 | 2XDN65 | 2XDN65 | 2XDN80 | 2XDN80 | 2XDN80 | 2XDN80 | 2XDN100 | 2XDN100 | ||
Connections onlet φ | mm | 2XDN50 | 2XDN65 | 2XDN65 | 2XDN65 | 2XDN80 | 2XDN80 | 2XDN80 | 2XDN80 | 2XDN100 | 2XDN100 | ||
Product weight(empty) | kg | 769 | 811 | 853 | 1134 | 1197 | 1261 | 1498 | 1589 | 1673 | 1864 |
Reference:
Dry cooling tower case | |
Case 1: used in chemical plant. | Case 2: used in chemical plant. Refrigerant: ethylic acid(flow: 372 ton/h)
|
![]() ![]() | ![]() ![]() |
Case 3: used in communication station as air conditioner outdoor unit in China. | Case 4: used in communication station as air conditioner outdoor unit
|
![]() | ![]() |