Submeraged Cooling System Adiabatic Dry Cooler For Server Room
The submeraged cooling system diagram by dry cooler:
Shenglin and Shenglin partner can offer one-stop solution:
For bitcoin mining farm, if use immersion cooling system, Shenglin dry cooler is the most cost-effective way to remove heat and a necessary component of the immersion cooling system, We designed a full range of immersion optimized dry coolers. From 5kW single fan unit to the V-shaped 48-921kW dry coolers. Made in China, sized to your needs.
Shenglin dry cooler features:
Standard arrangements include flat-bed vertical or horizontal airflow with V configurations to offer the smallest footprint.
Whether your application is cooling water / glycol for water cooled chillers, injection moulding machines, furnace equipment, CHP Engine Cooling or any other process. One or more of our units can be selected to give the most cost-effective solution to suit your space and noise requirement.
Energy saving free cooling is possible for much of the year for many applications.
Shenglin dry cooler technical parameter
Dry cooler D2 series parameter(fin space 2.1mm)
Type | D2-426- 10x630 | D2-445- 12x630 | D2-517- 12x630 | D2-525- 14x630 | D2-601- 14x630 | D2-596- 16x630 | D2-692- 16x630 | D2-676- 18x630 | D2-783- 18x630 | D2-921- 20x630 | |||
Capacity | Water | KW | 426.15 | 444.78 | 516.67 | 524.7 | 601.41 | 595.59 | 692.11 | 676.02 | 783.03 | 921.23 | |
20% Et. Glycol | KW | 413.85 | 427.83 | 504.38 | 507.9 | 586.16 | 572.94 | 676.71 | 653.42 | 767.64 | 905.78 | ||
Air flow | M3/h | 182123 | 229377 | 218543 | 267604 | 254816 | 301325 | 290850 | 338987 | 327612 | 351663 | ||
Fan | No. X φ | 2X5X630 | 2X6X630 | 2X6X630 | 2X7X630 | 2X7X630 | 2X8X630 | 2X8X630 | 2X9X630 | 2X9X630 | 2X10X630 | ||
Fan motor | A | 51 | 61.2 | 61.2 | 71.4 | 71.4 | 81.6 | 81.6 | 91.8 | 91.8 | 102 | ||
400/3N/50HZ | kW | 27.5 | 33 | 33 | 38.5 | 38.5 | 44 | 44 | 49.5 | 49.5 | 55 | ||
Sound pressure level | dB(A)10m | 68 | 69 | 69 | 70 | 70 | 71 | 71 | 72 | 72 | 73 | ||
Dimension | L | mm | 5250 | 6250 | 6250 | 7250 | 7250 | 8250 | 8250 | 9250 | 9250 | 10250 | |
H | mm | 1874 | 1874 | 1874 | 1874 | 1874 | 1874 | 1874 | 1874 | 1874 | 1874 | ||
D | mm | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 | ||
D1 | mm | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | ||
L1 | mm | 963 | 963 | 963 | 963 | 963 | 963 | 963 | 963 | 963 | 963 | ||
L2 | mm | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | ||
L3 | mm | 4963 | 5963 | 5963 | 6963 | 6963 | 7963 | 7963 | 8963 | 8963 | 9963 | ||
Connections inlet φ | mm | 2XDN100 | 2XDN100 | 2XDN100 | 2XDN100 | 2XDN125 | 2XDN125 | 2XDN125 | 2XDN125 | 2XDN125 | 4XDN1100 | ||
Connections onlet φ | mm | 2XDN100 | 2XDN100 | 2XDN100 | 2XDN100 | 2XDN125 | 2XDN125 | 2XDN125 | 2XDN125 | 2XDN125 | 4XDN1100 | ||
Product weight(empty) | kg | 2193 | 2224 | 2617 | 2586 | 3259 | 3244 | 3728 | 3643 | 4226 | 4283 |
How to Design a Dry Cooler?
Tell Shenglin the datas as following:
A. Required electrolyte inlet temperature?
B. Required electrolyte outlet temperature?
C. Electrolyte flow?
D. Ambient temperature?
E.Supply power(voltage-Hz-phase)
G.Any other requirements ?
Some Submeraged cooling system dry cooler reference:
![]() | ![]() |
Country: USA Application: Bitcoin immersion cooling system Cooling capacity: 1270kW Cooling medium: BC-888 Supply power: 415V/3P/60Hz Fan brand: Ziehl-Abegg
| Country: USA Application: Bitcoin immersion cooling system Cooling capacity: 171kW Cooling medium: bitcoin fluid Supply power: 415V/3P/60Hz Fan brand: Chinese brand
|