BTC GPUs Dielectric Fluid Submerged Server Cooling System
What's Immersion Cooling?
Immersion cooling refers to the process of immersing servers, GPUs, ASICs, and other IT hardware in a non-conductive fluid. The fluid is a far more effective cooling medium than air is and so higher efficiencies are achievable. Two-phase immersion cooling is similar but the fluid boils on the hot components.
Benefits of Immersion Cooling:
Reduce Operating Costs by 50%+
Power reduction by removing the fans from the miners (~18% – 25%)
Removal of supplementary cooling systems (Intake / Exhaust fans, etc. account for another 20% – 25%)
Increase the hash rate of your current equipment
Increase hardware lifespan
Increase the density of miners in your facility
Built in fire protection as our dielectric fluid is non-flammable
Technical parameter of dry cooler
Dry cooler D3 series parameter(fin space 2.1mm)
Type | D3-042- 1X800 | D3-046- 1X800 | D3-051- 1X800 | D3-087- 2X800 | D3-094- 2X800 | D3-103- 2X800 | D3-125- 3X800 | D3-146- 3X800 | D3-153- 3X800 | D3-175- 4X800 | D3-188- 4X800 | ||||||
Capacity | Water | 35℃ outdoor temp. | Inlet | 45℃, | KW | 42.1 | 46.1 | 50.6 | 87.3 | 93.6 | 102.9 | 124.9 | 145.9 | 153.3 | 174.5 | 187.9 | |
outlet | 40℃ | ||||||||||||||||
20% Glycol | Inlet | 45℃ | 40.8 | 45.1 | 49.7 | 84.5 | 91.8 | 100.9 | 119.4 | 143 | 150.4 | 168.9 | 184.3 | ||||
outlet | 40℃ | ||||||||||||||||
Medium | Water flow | M3/h | 7.3 | 8 | 8.8 | 15.2 | 16.3 | 17.9 | 21.7 | 25.4 | 26.6 | 30.3 | 32.7 | ||||
Pressure drop | kPa | 49 | 69 | 97 | 48 | 98 | 93 | 21 | 97 | 89 | 48 | 98 | |||||
Air flow | M3/h | 21454 | 20531 | 19696 | 42906 | 41061 | 39390 | 64364 | 61585 | 59087 | 85811 | 82120 | |||||
Fan motor(400V/3N/50HZ) | W | 1800 | 1800 | 1800 | 3600 | 3600 | 3600 | 5400 | 5400 | 5400 | 7200 | 7200 | |||||
A | 3.8 | 3.8 | 3.8 | 7.6 | 7.6 | 7.6 | 11.4 | 11.4 | 11.4 | 15.2 | 15.2 | ||||||
Fan | No X φ | 1x1 x800 | 1x1 x800 | 1x1 x800 | 1x2 x800 | 1x2 x800 | 1x2 x800 | 1x3 x800 | 1x3 x800 | 1x3 x800 | 2x2 x800 | 2x2 x800 | |||||
Sound pressure level | dB(A) | 50 | 50 | 50 | 51 | 51 | 51 | 53 | 53 | 53 | 54 | 54 | |||||
10m | |||||||||||||||||
Dimension | L | mm | 2000 | 2000 | 2000 | 3800 | 3800 | 3800 | 5600 | 5600 | 5600 | 3800 | 3800 | ||||
W | mm | 1084 | 1084 | 1084 | 1084 | 1084 | 1084 | 1084 | 1084 | 2108 | 2108 | 2108 | |||||
H | mm | 1328 | 1328 | 1328 | 1328 | 1328 | 1328 | 1328 | 1328 | 1328 | 1328 | 1328 | |||||
A | mm | 1728 | 1728 | 1728 | 3528 | 3528 | 3528 | 5328 | 5328 | 5328 | 3528 | 3528 | |||||
B1 | mm | -- | -- | -- | 1764 | 1764 | 1764 | 1776 | 1776 | 1776 | 1764 | 1764 | |||||
B2 | mm | -- | -- | -- | 1764 | 1764 | 1764 | 1776 | 1776 | 1776 | 1764 | 1764 | |||||
B3 | mm | -- | -- | -- | -- | -- | -- | 1776 | 1776 | 1776 | -- | -- | |||||
B4 | mm | -- | -- | -- | -- | -- | -- | -- | -- | -- | -- | -- | |||||
X | mm | 997 | 997 | 997 | 997 | 997 | 997 | 997 | 997 | 997 | 2021 | 2021 | |||||
Inlet φ | mm | 2” | 2” | 2” | 2 1/2” | 2 1/2” | 2 1/2” | 3’ | 3’ | 3’ | 4” | 4” | |||||
Inlet φ | mm | 2” | 2” | 2” | 2 1/2” | 2 1/2” | 2 1/2” | 3’ | 3’ | 3’ | 4” | 4” | |||||
Product weight(empty) | kg | 225 | 233 | 241 | 357 | 373 | 392 | 796 | 527 | 749 | 812 | 1062 |
We can OEM design dry cooler.
Tell us the datas as following:
A. Required water or electrolyte`s inlet temperature?
B. Required water or electrolyte`soutlet temperature?
C. Water or electrolyte`s flow?
D. Ambient temperature?
E. Supply power(voltage-Hz-phase)
G. Any other requirements ?
Professional system integration Customized size Thermodynamic calculations Authoritative seismic design Integrated wet curtain celdek7090 | Frame: Galvanized sheet sprayed (RAI 7035) Hot dip galvanized sheet Stainless steel plate Galvanized sheet | AC-EC fan: Protection grade ip55 Low energy consumption Inverter control High temperature resistant fan Explosion-proof fan | Various diameter fans are available: 800, 1~14 psc 910, 1~18 psc 1250, 1~8 psc 1800, 1~7 psc |
Pipe: Copper Copper nickel alloy Stainless steel Titanium | Fin: Epoxy coating Aluminum Copper: Tinned copper foil Blygold coating Stainless steel Titanium | Overhaul and cleaning: Easy to clean Optional access door or hinged fan panel Fin form for easy cleaning Robust material with high mechanical strength Easy to maintain | Different connection options: Flange connection Threaded connection Welding |
Some reference:
![]() | ![]() |
Country: USA Application: Bitcoin immersion cooling system Cooling capacity: 1270kW Cooling medium: BC-888 Supply power: 415V/3P/60Hz Fan brand: Ziehl-Abegg
| Country: USA Application: Bitcoin immersion cooling system Cooling capacity: 171kW Cooling medium: bitcoin fluid Supply power: 415V/3P/60Hz Fan brand: Chinese brand
|