Two Phase Immersion Liquid Cooling Dry Chiller For Submeraged Cooling System
What's immersion cooling or submeraged cooling?
Also known as liquid submersion cooling. It is the practice of submerging computer components (or full servers) in a thermally, but not electrically, conductive liquid (dielectric coolant) allowing higher heat transfer performance than air and many other benefits.
Why many large data centers have already moved or are considering the move to immersion cooling?
1. Up to 25% increase in power efficiency
2. Up to 80% cost reduction
3. Up to 60% hashrate increase
4. 50%+ equipment lifespan.
For bitcoin mining farm, if use immersion cooling system, our dry cooler is the most cost-effective way to remove heat and a necessary component of the immersion cooling system, We designed a full range of immersion optimized dry coolers. From 5kW single fan unit to the V-shaped 48-921kW dry coolers. Made in China, sized to your needs.
Also, we have whole immersion cooling system partner in USA and European, they can also offer the whole system proposal for you.
Features of adiabatic dry coolers
1. Material options:
A. Heavy-gauge hot-dip galvanized steel is used for unit steel panels and structural elements featuring a zinc aluminium coating.
2. Heat transfer media:
A. The dry cooler is constructed of staggered and seamless copper tubes (15,9 or 12,7 diameter) with aluminium, rippled and corrugated fins (0,14 or 0,17 thickness).
B. 2.5 mm fin spacing for optimal air turbulence
C. Thick and seamless copper headers and threaded steel connections
D. Pressure tested at 30 bar
E. Try our options for aggressive environments: special pre-coated anti-corrosion aluminium fins or copper fins (0,2 mm thickness).
3. Air movement system:
A. Axial fan with exceptionally compact direct drive short integrated motor and fan guard.
B. The fan features an impeller and motor and is balanced as a complete unit using dynamic single plane balancing. Balance grade is G6.3.
C. Fan and motor totally maintenance free.
D. Bearings seals and motor encapsulation for long service life.
Our USA partner can offer the data center cooling system solution, like this way:
Shenglin dry cooler selection software:
Shenglin dry cooler technical parameter
Dry cooler D2 series parameter(fin space 2.1mm)
Type | D2-426- 10x630 | D2-445- 12x630 | D2-517- 12x630 | D2-525- 14x630 | D2-601- 14x630 | D2-596- 16x630 | D2-692- 16x630 | D2-676- 18x630 | D2-783- 18x630 | D2-921- 20x630 | |||
Capacity | Water | KW | 426.15 | 444.78 | 516.67 | 524.7 | 601.41 | 595.59 | 692.11 | 676.02 | 783.03 | 921.23 | |
20% Et. Glycol | KW | 413.85 | 427.83 | 504.38 | 507.9 | 586.16 | 572.94 | 676.71 | 653.42 | 767.64 | 905.78 | ||
Air flow | M3/h | 182123 | 229377 | 218543 | 267604 | 254816 | 301325 | 290850 | 338987 | 327612 | 351663 | ||
Fan | No. X φ | 2X5X630 | 2X6X630 | 2X6X630 | 2X7X630 | 2X7X630 | 2X8X630 | 2X8X630 | 2X9X630 | 2X9X630 | 2X10X630 | ||
Fan motor | A | 51 | 61.2 | 61.2 | 71.4 | 71.4 | 81.6 | 81.6 | 91.8 | 91.8 | 102 | ||
400/3N/50HZ | kW | 27.5 | 33 | 33 | 38.5 | 38.5 | 44 | 44 | 49.5 | 49.5 | 55 | ||
Sound pressure level | dB(A)10m | 68 | 69 | 69 | 70 | 70 | 71 | 71 | 72 | 72 | 73 | ||
Dimension | L | mm | 5250 | 6250 | 6250 | 7250 | 7250 | 8250 | 8250 | 9250 | 9250 | 10250 | |
H | mm | 1874 | 1874 | 1874 | 1874 | 1874 | 1874 | 1874 | 1874 | 1874 | 1874 | ||
D | mm | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 | 2100 | ||
D1 | mm | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | 2000 | ||
L1 | mm | 963 | 963 | 963 | 963 | 963 | 963 | 963 | 963 | 963 | 963 | ||
L2 | mm | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | ||
L3 | mm | 4963 | 5963 | 5963 | 6963 | 6963 | 7963 | 7963 | 8963 | 8963 | 9963 | ||
Connections inlet φ | mm | 2XDN100 | 2XDN100 | 2XDN100 | 2XDN100 | 2XDN125 | 2XDN125 | 2XDN125 | 2XDN125 | 2XDN125 | 4XDN1100 | ||
Connections onlet φ | mm | 2XDN100 | 2XDN100 | 2XDN100 | 2XDN100 | 2XDN125 | 2XDN125 | 2XDN125 | 2XDN125 | 2XDN125 | 4XDN1100 | ||
Product weight(empty) | kg | 2193 | 2224 | 2617 | 2586 | 3259 | 3244 | 3728 | 3643 | 4226 | 4283 |
How to Design a Dry Cooler?
Tell Shenglin the datas as following:
A. Required electrolyte inlet temperature?
B. Required electrolyte outlet temperature?
C. Electrolyte flow?
D. Ambient temperature?
E.Supply power(voltage-Hz-phase)
G.Any other requirements ?
Why choose us:
1) We can help buyers design specific products or produce products according to buyers' design
2) We can print logo according to buyers' requirement
3) We has exported to many countries,such as Singapore, Philippines, Vietnam, Argentina, Peru, Mongolia, Hong Kong, UAE,Russia, Poland etc.
4) Design term:We have professional design team.
5) Professional factory: We are manufacturer, specializing in manufacturing heat exchangers for over 16years, competitive price with good quality.
6)Rapid response to your needs: We will reply within 24 hours after receiving you letter. If you have urgent thing, welcome to call us.
7)The Most Efficient Service, Best Quality and Excellent Reputation.